Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
ACS Environ Au ; 3(4): 242-248, 2023 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-37483304

RESUMEN

Products and starting materials containing volatile organic compounds (VOCs) can easily be found in a variety of businesses, making them a common source of occupational exposure. To prevent negative impacts on employee health, field industrial hygienists must conduct regular sampling to ensure exposures remain below the regulatory limits set by governmental and professional associations. As such, the need for sensitive and reliable exposure assessment techniques becomes evident. Over the preceding decade, the industrial hygiene research group at the University of Alabama at Birmingham (UAB) has been working on the development of an emerging, preanalytical technique known as photothermal desorption (PTD) to improve upon the analytical sensitivity of currently employed methods. PTD's novel design uses pulses of high-energy light to desorb analytes from thermally conductive, carbonaceous sorbents, to be delivered to downstream analytical detectors. Since PTD's conception, the theoretical framework and advances in sorbent fabrication have been investigated; however, further work is needed to produce a field-ready sampling device for use with PTD. As such, objectives of the present work were to design a PTD-compatible diffusive sampler prototype and characterize the prototype's sampling efficiencies for toluene, n-hexane, trichloroethylene, and isopropyl alcohol. In pursuit of these objectives, the study empirically quantified the sampled masses of toluene, n-hexane, trichloroethylene, and isopropyl alcohol, at occupationally relevant air concentrations, to be 12.17 ± 0.06, 8.2 ± 0.1, 3.97 ± 0.06, and 8.0 ± 0.1 mg, respectively. Moreover, the analyte sampling efficiencies were found to be 2.2 ± 0.1, 1.7 ± 0.1, 1.2 ± 0.1, and 0.51 ± 0.05 (unitless) when comparing empirically (i.e., laboratory observed) sample mass values to theoretically predicted values. The sampling efficiencies and collected sample masses reported herein demonstrate the promising design of PTD-compatible diffusive samplers. When used in conjunction with the PTD method, the prototype samplers present strong evidence for improving analytical sensitivity in exposure assessments of VOCs in the workplace.

2.
Environ Health Insights ; 16: 11786302221078430, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35173446

RESUMEN

Passive sampling using diffusive samplers has become popular as a convenient means of occupational compliance sampling for volatile organic compounds (VOCs). However, diffusive samplers possess sensitivity limitations when sampling low concentrations and for short durations. To reduce these limitations, our research team has been developing a novel method of sample recovery called photothermal desorption (PTD), which uses high energy visible light pulses to desorb analytes from sampling media. Newly designed passive samplers that will use PTD will be equipped with windscreens in a similar design with the 3M OVM. In a preliminary design effort, the present work sought to find a suitable, windscreen for future use in a PTD-compatible diffusive sampler prototype that would be similar to those found in commercially available diffusive samplers. To do so, 2 stainless steel windscreens (wire diameters 0.015″ and 0.0055″ respectively) were compared to a standard windscreen by exposing modified (ie, steel mesh installed) and non-modified 3M OVM samplers to 3 analytes. To mimic in-field conditions, each sampler was exposed to analyte concentrations at their short-term and personal exposure limits (STELs and PELs). From these comparisons, it was determined that the 0.0055″ mesh was most similar to the standard windscreen in contributing to sample collection based on the uptake and concentration determinations for each analyte and concentration.

3.
Artículo en Inglés | MEDLINE | ID: mdl-35162289

RESUMEN

In recent years, the introduction and use of new nanomaterials in construction has increased at a rapid rate. Exterior surface paints have been a product that have had these nanomaterials added to them. In this study, the effects of natural weathering and exposure to atmospheric agents was examined to determine the detrimental effects on outdoor paint that has been created with nanomaterials. Data collected over the course of the yearlong study indicate that the nanoparticles of the titanium dioxide were eliminated rapidly. Further testing indicated that various elements of weathering were affecting the physical integrity of the paint. The weathering agents that appeared to have the greatest effect on the samples were acid deposition and total precipitation. There was a strong association between carbon monoxide and the effects on the panels. These results can lead to new plans for assessments involving the synergistic effects of all weathering agents.


Asunto(s)
Polvo , Pintura , Aerosoles/análisis , Titanio
4.
Nanomaterials (Basel) ; 12(4)2022 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-35214991

RESUMEN

Millions of workers are occupationally exposed to volatile organic compounds (VOCs) annually. Current exposure assessment techniques primarily utilize sorbent based preconcentrators to collect VOCs, with analysis performed using chemical or thermal desorption. Chemical desorption typically analyzes 1 µL out of a 1 mL (0.1%) extraction volume providing limited sensitivity. Thermal desorption typically analyzes 100% of the sample which provides maximal sensitivity, but does not allow repeat analysis of the sample and often has greater sensitivity than is needed. In this study we describe a novel photothermal desorption (PTD) technique to bridge the sensitivity gap between chemical desorption and thermal desorption. We used PTD to partially desorb toluene from three carbonaceous substrates; activated carbon powder (AC-p), single-walled carbon nanotube (SWNT) powder (SWNT-p) and SWNT felts (SWNT-f). Sorbents were loaded with 435 ug toluene vapour and irradiated at four light energies. Desorption ranged from <0.007% to 0.86% with a single flash depending on substrate and flash energy. PTD was significantly greater and more consistent in SWNT-f substrates compared to AC-p or SWNT-p at all irradiation energies. We attribute the better performance of SWNT-f to greater utilization of its unique nanomaterials properties: high thermal conductivity along the nanotube axis, and greater interconnection within the felt matrix compared to the powdered form.

5.
J Occup Environ Med ; 63(11): e783-e791, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34419986

RESUMEN

OBJECTIVE: Health care professionals and governmental agencies are in consensus regarding contact and droplet transmission of infectious diseases. However, personal protective equipment (PPE) efficacy is not considered for aerosol or airborne transmission of infectious diseases. This review discusses the inhalation of virus-laden aerosols as a viable mechanism of transmission of various respiratory infectious diseases and PPE efficacy. METHODS: The Preferred Reporting Items for Systematic reviews, and Meta-Analysis (PRISMA) guidelines was used. RESULTS: The transmission of infectious disease is of concern for all respirable diseases discussed (SARS-CoV-1, SARS-CoV-2, MERS, influenza, and tuberculosis), and the effectiveness of facemasks is dependent on the efficiency of the filter, fit, and proper use. CONCLUSION: PPE should be the last resort in preventing the spread of infectious disease and should only be used for protection and not to control the transmission.


Asunto(s)
COVID-19 , Enfermedades Transmisibles , Aerosoles , Humanos , Equipo de Protección Personal , SARS-CoV-2
6.
ACS Omega ; 6(8): 5415-5422, 2021 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-33681581

RESUMEN

Volatile organic compounds (VOCs) pose an occupational exposure risk due to their commonplace usage across industrial and vocational sectors. With millions of workers annually exposed, monitoring personal VOC exposures becomes an important task. As such, there is a need to improve current monitoring techniques by increasing sensitivity and reducing analysis costs. Recently, our lab developed a novel, preanalytical technique known as photothermal desorption (PTD). PTD uses pulses of high-energy, visible light to thermally desorb analytes from carbonaceous sorbents, with single-walled carbon nanotube buckypapers (BPs) having the best overall performance. To apply this new technology most effectively for chemical analysis, a better understanding of the theoretical framework of the thermal phenomena behind PTD must be gained. The objectives of the present work were 3-fold: measure the thermal response of BPs during irradiation with light; determine the best method for conducting such measurements; and determine the thermal conductivity of BPs. BPs were exposed to four energy densities, produced by light pulses, ranging from 0.28 to 1.33 J/cm2, produced by a xenon flash lamp. The resulting temperature measurements were obtained via fast response thermocouple (T/C) mounted to BPs by three techniques (pressing, adhering, and embedding). Temperature increase measured by T/C using the adhering and pressing techniques resulted in similar values, 29.2 ± 0.8 to 56 ± 3 °C and 29.1 ± 0.9 to 50 ± 5 °C, respectively, while temperature increase measured by embedding the T/C into the BP showed statistically larger increases ranging from 35.2 ± 0.9 to 76 ± 4 °C. Peak BP temperatures for each mounting technique were also compared with the temperatures generated by the light source, which resulted in embedded BPs demonstrating the most temperature conversion among the techniques (74-86%). Based on these results, embedding T/Cs into the BP was concluded to be the best way to measure BP thermal response during PTD. Additionally, the present work modeled BP thermal conductivity using a steady-state comparative technique and found the material's conductivity to be 10.6 ± 0.6 W/m2. The present work's findings will help pave the way for future developments of the PTD method by allowing calculation of the energy density necessary to attain a desired sorbent temperature and providing a means for comparing BP fabrication techniques and evaluating BP suitability for PTD before conducting PTD trials with analytes of interest. Sorbents with greater thermal conductivity are expected to desorb more evenly and withstand higher energy density exposures.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA