1.
Insights Imaging ; 11(1): 88, 2020 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-32748218

RESUMEN

OBJECTIVES: Computed tomography (CT) scanning is an essential part of diagnostic and treatment plans, providing swift and accurate diagnostic images. The aim of this study is to develop diagnostic reference levels (DRLs) for the adult common CT examination in the United Arab Emirates (UAE). METHODS: This study presents results of the survey of CT dose indices. The data were collected from 91% of the scanners registered at the Ministry of Health and Prevention (MOHAP) for five common examinations: head, chest, and abdomen-pelvis with and without CM. RESULTS: CT dose index, dose-length product, and patient weight were analyzed; the reference dose was calculated on the 75th percentile, and an achievable dose was proposed from the median value. The results were compared with the UAE initial National Dose Report as well as the international reports. The proposed dose for CTDIvol (mGy) and DLP (mGy cm) is as follows: head without CM 40 and 695, head with CM 48 and 820, chest 10 and 275, abdomen-pelvis without CM 14 and 810, and abdomen-pelvis with CM 20 and 1025. CONCLUSIONS: The results show low dose variations between the MOHAP scanners. The data also revealed CTDIvol and DLP values comparable to those in the initial NDRL report and international standards. The establishment of diagnostic reference levels will require a continuous dose monitoring system.

2.
Phys Med ; 39: 16-24, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28711184

RESUMEN

OBJECTIVES: To establish national diagnostic reference levels (DRLs) in Egypt for computed tomography (CT) examinations of adults and identify the potential for optimization. METHODS: Data from 3762 individual patient's undergoing CT scans of head, chest (high resolution), abdomen, abdomen-pelvis, chest-abdomen-pelvis and CT angiography (aorta and both lower limbs) examinations in 50 CT facilities were collected. This represents 20% of facilities in the country and all of the 27 Governorates. Results were compared with DRLs of UK, USA, Canada, Japan, Australia and France. RESULTS: The Egyptian DRLs for CTDIvol in mGy are for head: 30, chest (high resolution): 22, abdomen (liver metastasis): 31, abdomen-pelvis: 31, chest-abdomen-pelvis: 33 and CT angiography (aorta and lower limbs): 37. The corresponding DRLs for DLP in mGy.cm are 1360, 420, 1425, 1325, 1320 and 1320. For head CT, the Egyptian DRL for CTDIvol is 2-3 times lower than the DRLs from other countries. However, the DRL in terms of DLP is in the same range or higher as compared to others. The Egyptian DRL for chest CT (high resolution) is similar to others for DLP but higher for CTDIvol. For abdomen and abdomen-pelvis DRLs for CTDIvol are higher than others. For DLP, the DRLs for abdomen are higher than DRL in UK and lower than those in Japan, while for abdomen-pelvis they are higher than other countries. CONCLUSION: Despite lower DRLs for CTDIvol, an important consistent problem appears to be higher scan range as DRLs for DLP are higher.


Asunto(s)
Dosis de Radiación , Tomografía Computarizada por Rayos X , Egipto , Humanos , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA