Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Cureus ; 16(7): e64645, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39156417

RESUMEN

Platypnea-orthodoxia syndrome (POS) is a clinical condition that causes dyspnea and hypoxia in the sitting and standing positions. In this case, a 67-year-old man showed hypoxemia after undergoing the Bentall procedure that worsened in the standing position during rehabilitation. Contrast-enhanced computed tomography of the thorax and abdomen revealed no cause of respiratory failure. POS was suspected as the cause of the positional exacerbation of oxygen saturation. A bubble study showed a positive grade IV within three heartbeats on transthoracic echocardiography, which also confirmed an intracardiac shunt caused by a patent foramen ovale (PFO). Percutaneous PFO closure was performed, and hypoxemia was immediately resolved. Various factors were considered to cause the POS, including right heart failure, constrictive pericarditis, and postoperative adhesions, and each of these factors was discussed. POS after open-heart surgery is very rare. This is the first reported case of POS treated with a closure device following the Bentall procedure.

2.
SAGE Open Med Case Rep ; 8: 2050313X20921081, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32577280

RESUMEN

A 68-year-old man was scheduled to undergo percutaneous coronary intervention for in-stent total occlusion of the severely tortuous right coronary artery. Intravascular ultrasound revealed heavy in-stent calcification. Lesion atherectomy was required; however, severe proximal vessel tortuosity was detected. We introduced a 7-Fr guide-extension catheter beyond the severely tortuous part and performed rotational atherectomy with a 1.5 mm burr. However, the balloon could not expand; therefore, we changed to an orbital atherectomy system. Subsequently, the balloon successfully expanded, and intravascular ultrasound revealed an enlarged lumen. Severe proximal vessel tortuosity limits the use of atherectomy devices; however, a guide-extension catheter delivers the atherectomy device beyond the tortuosity. The delivery of the orbital atherectomy system inside the guide-extension catheter is easy due to its low profile; the debulking effect increases with the number of passes and rotational speed. This strategy is a useful option for treating severe calcified lesions with proximal vessel tortuosity.

3.
Int J Cardiovasc Imaging ; 36(10): 1811-1819, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32524242

RESUMEN

We aimed to evaluate the additional debulking efficacy of low-speed rotational atherectomy (RA) after high-speed RA by using intravascular imaging. A total of 22 severe calcified coronary lesions in 19 patients (age, 74 ± 10 years; 74% male) were retrospectively analyzed. All of these lesions underwent RA under optical coherence tomography (OCT) or optical frequency domain imaging (OFDI) guidance. At first, we performed high-speed RA with 220,000 rpm until the reduction of rotational speed disappeared; then, low-speed RA with 120,000 rpm using the same burr size was performed. OCT or OFDI was performed after both high-speed and low-speed RAs, and the minimum lumen area were compared. The initial and final burr sizes of high-speed RA were 1.5 (1.5-1.75) and 1.75 (1.5-2.0) mm, respectively. The number of sessions, total duration time, and maximum decreased rotational speed during high-speed RA were 11 ± 5 times, 113 ± 47 s, and 4000 (3000-5000) rpm, respectively. During low-speed RA, the number of sessions, total duration time, and maximum reduction of rotational speed were 3 ± 1 times, 32 ± 11 s, and 1000 (0-2000) rpm, respectively. The minimum lumen area was similar between after high-speed and after low-speed RA [2.61 ± 1.03 mm2 (after high-speed RA) vs. 2.65 ± 1.00 mm2 (after low-speed RA); P = 0.91]. Additional low-speed RA immediately after sufficient debulking by high-speed RA was not associated with increased lumen enlargement. There was no clinical efficacy of low-speed RA after high-speed RA.


Asunto(s)
Angioplastia Coronaria con Balón , Aterectomía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Calcificación Vascular/terapia , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/efectos adversos , Aterectomía Coronaria/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Calcificación Vascular/diagnóstico por imagen
4.
SAGE Open Med Case Rep ; 8: 2050313X20907825, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32110413

RESUMEN

A 63 year-old woman with claudication underwent endovascular therapy for diffuse stenosis of the right superficial femoral artery in our hospital. We performed paclitaxel-coated balloon angioplasty using the IN.PACT™ Admiral™ and achieved acceptable results. After 42 days, we performed follow-up optical frequency domain imaging for the right superficial femoral artery lesion treated with paclitaxel-coated balloon and observed several high-intensity regions with attenuation on the lumen surface. Sustained drug availability is a notable characteristic of paclitaxel-coated balloon. To the best of our knowledge, this is the first report on the visualization of sustained drug retention on the lumen surface using follow-up optical frequency domain imaging after paclitaxel-coated balloon angioplasty in a human patient with superficial femoral artery disease.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA