1.
Magn Reson Med Sci ; 18(3): 208-218, 2019 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-30416180

RESUMEN

PURPOSE: To develop a fast 3D MRI simulator for arbitrary k-space sampling using a graphical processing unit (GPU) and demonstrate its performance by comparing simulation and experimental results in a real MRI system. MATERIALS AND METHODS: A fast 3D MRI simulator using a GeForce GTX 1080 GPU (NVIDIA Corporation, Santa Clara, CA, USA) was developed using C++ and the CUDA 8.0 platform (NVIDIA Corporation). The unique advantage of this simulator was that it could use the same pulse sequence as used in the experiment. The performance of the MRI simulator was measured using two GTX 1080 GPUs and 3D Cones sequences. The MRI simulation results for 3D non-Cartesian sampling trajectories like 3D Cones sequences using a numerical 3D phantom were compared with the experimental results obtained with a real MRI system and a real 3D phantom. RESULTS: The performance of the MRI simulator was about 3800-4900 gigaflops for 128- to 4-shot 3D Cones sequences with 2563 voxels, which was about 60% of the performance of the previous MRI simulator optimized for Cartesian sampling calculated for a Cartesian sampling gradient-echo sequence with 2563 voxels. The effects of the static magnetic field inhomogeneity, radio-frequency field inhomogeneity, gradient field nonlinearity, and fast repetition times on the MR images were reproduced in the simulated images as observed in the experimental images. CONCLUSION: The 3D MRI simulator developed for arbitrary k-space sampling optimized using GPUs is a powerful tool for the development and evaluation of advanced imaging sequences including both Cartesian and non-Cartesian k-space sampling.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Análisis de la Onda del Pulso/métodos , Humanos
2.
Magn Reson Med Sci ; 18(1): 88-95, 2019 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-29769457

RESUMEN

We developed ultrashort echo-time (UTE) imaging sequences with 3D Cones trajectories for a home-built compact MRI system using a 1.5T superconducting magnet and an unshielded gradient coil set. We achieved less than 7 min imaging time and obtained clear in vivo images of a human forearm with a TE of 0.4 ms. We concluded that UTE imaging using 3D Cones acquisition was successfully implemented in our 1.5T MRI system.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética , Brazo/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Imanes , Superconductividad
3.
Magn Reson Med Sci ; 17(2): 174-183, 2018 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-28367906

RESUMEN

Spiral MRI sequences were developed for a 9.4T vertical standard bore (54 mm) superconducting magnet using unshielded and self-shielded gradient coils. Clear spiral images with 64-shot scan were obtained with the self-shielded gradient coil, but severe shading artifacts were observed for the spiral-scan images acquired with the unshielded gradient coil. This shading artifact was successfully corrected with a phase-correction technique using reference scans that we developed based on eddy current field measurements. We therefore concluded that spiral imaging sequences can be installed even for unshielded gradient coils if phase corrections are performed using the reference scans.


Asunto(s)
Imagen por Resonancia Magnética , Superconductividad , Artefactos , Humanos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos