Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 22(22)2022 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-36433245

RESUMEN

A novel, low-cost, sensitive microwave microfluidic glucose detecting biosensor incorporating molecularly imprinted polymer (MIP) is presented. The sensing device is based on a stub resonator to characterize water glucose solutions. The tip of one of the stubs is coated with MIP to increase the selectivity of the sensor and hence the sensitivity compared to the uncoated or to the coated with non-imprinted polymer (NIP) sensor. The sensor was fabricated on a FR4 substrate for low-cost purposes. In the presence of the MIP, the sensor loaded with a glucose solution ranging from 50 mg/dL to 400 mg/dL is observed to experience an absorption frequency shift of 73 MHz when the solutions flow in a microfluidic channel passing sensing area, while the lower limit of detection (LLD) of the sensor is discovered to be 2.4 ng/dL. The experimental results show a high sensitivity of 1.3 MHz/(mg/dL) in terms of absorption frequency.


Asunto(s)
Impresión Molecular , Polímeros Impresos Molecularmente , Impresión Molecular/métodos , Microondas , Límite de Detección , Glucosa
2.
Sensors (Basel) ; 22(9)2022 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-35590955

RESUMEN

A label-free, sensitive, miniaturized sensing device was developed for detecting living cells in their flow stream. The outstanding performance of this biosensor in distinguishing living cells in cell suspension was achieved by integrating microstrip stub resonator above a microfluidic structure using the metallic nanowire-filled membrane technology. The cell suspension flows in a microfluidic channel placed between the tip of the stub resonator and its ground plane as the substrate to take advantage of the uniform and concentrated field distribution. We studied the changes in relative permittivity due to the presence of a single living cell in the phase of the transmitted signal (S21). An average variation of as much as 22.85 ± 1.65° at ~11.1 GHz is observed for the living cell sensing using this optimized device. This biosensor could detect rapid flowing cells in their biological medium in real-time and hence, can be used as an early diagnosis and monitoring tool for diseases.


Asunto(s)
Técnicas Biosensibles , Nanocables , Microfluídica , Microondas , Tecnología
3.
Sensors (Basel) ; 19(23)2019 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-31795086

RESUMEN

We propose a novel platform for detecting as well as measuring the size of individual droplets in microfluidic channels using microstrip transmission lines. The most outstanding feature of our platform is that, as opposed to previous related works, its design allows for the droplet to flow in a microfluidic channel fabricated between the top strip and the ground plane of a microstrip transmission line. This provides enhanced interaction of the electromagnetic field with the detected droplets. The proposed design allows us to measure droplet size directly from the phase of the microwave signal, without the need for a resonator. The platform is based on low temperature co-fired ceramic (LTCC), which makes it more compatible with Radiofrequency (RF) and microwave technology than platforms used in previous works. With this platform, we are able to measure droplets as small as 150 µm in radius. It is worth pointing out that our device could also be used for detection, counting and measurement of other microscopic objects.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA