Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
G Ital Cardiol (Rome) ; 21(11 Suppl 1): 4S-12S, 2020 11.
Artículo en Italiano | MEDLINE | ID: mdl-33295329

RESUMEN

Since its advent, transcatheter aortic valve implantation (TAVI) has experienced a continuous expansion, thanks to extraordinary clinical results and to the dramatic increase of safety, enabled by improvements of prosthesis and delivery systems, refinement of implantation techniques, increasing operator experience, and use of computed tomography scan for procedural planning. However, complications rates are still not negligible. As vascular complications, and, particularly, access-related complications are among the most frequent adverse events, all TAVI operators should know how to prevent and how to manage those potentially catastrophic situations. Here we provide an overview of the most frequent access site vascular complications and the respective treatment options.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
G Ital Cardiol (Rome) ; 18(10): 727-733, 2017 Oct.
Artículo en Italiano | MEDLINE | ID: mdl-29105687

RESUMEN

BACKGROUND: Aortic valve stenosis is the most common valvular disease in the elderly. Transcatheter aortic valve implantation represents a viable alternative to conventional aortic valve replacement. In our Department, the transapical approach is the preferred method in patients with severe peripheral vascular disease. The aim of this study was to analyze the early and midterm results of Symetis Acurate TA implantation in our series. METHODS: From June 2013 to January 2017, 21 patients with severe peripheral vascular disease (11 male, mean age 78 ± 2.8 years) underwent transapical implantation of the Symetis Acurate TA device. Mean logistic EuroSCORE I was 21.9 ± 8.6, mean left ventricular ejection fraction was 51.9 ± 12.2%, and mean aortic gradient was 46.7 ± 12.3 mmHg. Valve implantation was performed through a left anterior minithoracotomy. Patients were followed up on a regular basis. Cardiac echocardiographic assessment was performed at 6 months post-implantation. RESULTS: Valve implantation was successful in all patients. Valve sizes were as follows: 7 size S, 6 size M, and 8 size L. Two patients died before hospital discharge (9.5%). Among survivors, 2 patients showed more than mild aortic regurgitation at discharge. Mean aortic gradient was 13.1 ± 4.3 mmHg (p<0.01). Median follow-up was 11.3 months. Mean NYHA class at follow-up was 1.9 ± 0.4 (p<0.05). Mean actuarial survival was 80%. CONCLUSIONS: Our series, even if small, demonstrates that transapical implantation of the Symetis Acurate TA device represents a viable solution in patients with severe peripheral vascular disease carrying a high operative risk. The relatively high operative mortality may be attributable to the learning curve of our team.


Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Enfermedades Vasculares/complicaciones , Anciano , Femenino , Humanos , Masculino , Diseño de Prótesis , Medición de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
3.
Metabolism ; 57(5): 593-7, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18442619

RESUMEN

Metabolic syndrome (MS) is associated with an increased risk of coronary heart disease, stroke, and cardiovascular mortality; but its effect on patients undergoing cardiac revascularization is still unclear. Robust evidence demonstrates that diabetes mellitus and insulin resistance are among the main risk factors for restenosis in patients requiring percutaneous myocardial revascularization. The recent advent of drug-eluting stents (DESs) has significantly reduced the incidence of restenosis compared with bare-metal stents, both in nondiabetic and in diabetic patients. The aim of the study was to evaluate the effect of MS on the risk of binary restenosis in DES implant recipients. One hundred eighty-nine recipients of successful DES implants performed between January and March 2005 for stable coronary artery disease underwent 1-year clinical and angiographic follow-up. Body mass index (BMI), blood pressure, fasting blood glucose, and lipid profile were determined. Metabolic syndrome was defined according to the National Cholesterol Education Program Adult Treatment Panel III criteria, with the waist criterion being substituted by a BMI>or=28.8 kg/m2. Metabolic and anthropometric information for MS diagnosis was available for 148 of 189 patients; 87 of 148 patients (58%) had MS. Patients with MS had higher BMI (28.4+/-3.8 vs 26+/-2.7 kg/m2, P<.0001), systolic blood pressure (133+/-14 vs 124+/-14 mm Hg, P=.0004), and fasting glucose (113+/-37 vs 92+/-17 mg/dL, P<.0001). They also had higher serum triglycerides (154+/-94 vs 113+/-43, P=.0018) and lower high-density lipoprotein cholesterol levels (39+/-9 vs 46+/-10, P<.0001). Rates of restenosis (10.5% vs 8.1%, P=not significant [NS]), target vessel revascularization (10.5% vs 11.3%, P=NS), and major adverse cardiac events (11.6% vs 14.5%, P=NS) were not significantly different in patients with MS compared with those without MS, nor was any association found between increased end point risk and presence of MS. When patients were subdivided into 6 subgroups by the presence of 0, 1, 2, 3, 4, or 5 of the MS components, restenosis rates were not significantly different among subgroups. In conclusion, MS is not associated with higher rates of restenosis, target vessel revascularization, or major adverse cardiac events; and no additional MS feature was associated with an increased risk.


Asunto(s)
Angioplastia Coronaria con Balón , Reestenosis Coronaria/epidemiología , Stents Liberadores de Fármacos , Síndrome Metabólico/complicaciones , Anciano , Angiografía Coronaria , Reestenosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA