Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Clin Orthop Surg ; 9(3): 263-269, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28861192

RESUMEN

BACKGROUND: The objective of this study was to compare clinical and radiological outcomes of total hip arthroplasty (THA) between ankylosing spondylitis (AS) of the hip joint and avascular necrosis (AVN) of the femoral head. METHODS: Thirty patients (30 hips) underwent cementless THA for AS between 2003 and 2012. They were compared to 30 patients (30 hips) who underwent the same procedure for AVN of the femoral head. Each group was matched for age and gender, and both groups had similar preoperative demographic characteristics. All cases were followed for minimum 4 postoperative years. Clinical evaluation was based on operation time, intraoperative blood loss, quantity of postoperative drainage, Harris Hip Score (HHS), and range of motion (ROM). Radiological results were evaluated by acetabular cup anteversion and inclination, femoral stem orientation, pre- and postoperative leg length discrepancy, and postoperative complications. RESULTS: The operation time was significantly longer in the AS group (120.2 ± 26.2 min) than in the AVN group (79.5 ± 11.1 min). The volume of postoperative drainage was significantly greater in the AS group (764.5 ± 355.4 mL vs. 510.5 ± 195.6 mL). Preoperative HHS was lower in the AS group (55.6 ± 13.8 vs. 59.2 ± 2.8). Similarly, postoperative HHS was significantly lower in the AS group (92.8 ± 2.7 vs. 97.4 ± 2.6). The arc of ROM was improved from 146.5° ± 13.2° preoperatively to 254.7° ± 17.2° postoperatively in the AS group and from 182.6° ± 15.5° to 260.4° ± 13.7° in the AVN group. Implant position and postoperative leg length discrepancy were not different between the groups. However, three cases of heterotopic ossification was observed in the AS group, whereas only 1 case was found in the AVN group. One deep infection and one aseptic stem loosening were found in the AS group, whereas none was observed in the AVN group. CONCLUSIONS: Cementless THA showed satisfactory clinical and radiological results in both groups, despite the longer operation time, larger blood loss volume, and lower HHS score of the AS group. Our findings suggest that cementless THA is an effective and reliable treatment for both AS and AVN.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Necrosis de la Cabeza Femoral/cirugía , Espondilitis Anquilosante/cirugía , Adulto , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Osificación Heterotópica/diagnóstico por imagen , Osificación Heterotópica/cirugía , Radiografía , Espondilitis Anquilosante/diagnóstico por imagen , Resultado del Tratamiento , Adulto Joven
2.
Hip Pelvis ; 29(1): 77-80, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28316966

RESUMEN

Femoral neck stress fracture occured commonly in athlete and military recruit populations, some of them are bilateral. Bilateral femoral neck stress fracture that associated with other occupation is very uncommon. We report a bilateral femoral neck stress fracture case that presented with unilateral symptoms in a male shipman laborer. The patient was successfully treated conservatively. Stress fracture sometimes occur associated with an unexpected specific occupation. Consideration of bilateral involvement is highly important in managing stress fracture.

3.
J Orthop ; 14(1): 171-175, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28070149

RESUMEN

OBJECTIVE: Present helpful measures to prevent expected complications that occur in patients with liver cirrhosis undergoing arthroplasty. METHODS: 218 patients who underwent hip or knee arthroplasty were included in this study. Prognoses of patients with underlying disease of liver cirrhosis and those without are compared with measures. RESULTS: Patients with liver cirrhosis show an increase in amount of bleeding, hospital stay and infection rate compared to those who do not. CONCLUSION: The risk of arthroplasty on patients with liver cirrhosis is higher than normal patients. Surgeons should carefully assess all cirrhotic patients pre- and postoperatively.

4.
J Arthroplasty ; 32(1): 37-42, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27633946

RESUMEN

BACKGROUND: In this study, we tried to assess if combined method (intravenous [IV] and topical) of tranexamic acid (TXA) administration, which has been shown to be superior in conventional arthroplasty, has similar effect in navigational arthroplasty compared to administration of drug either individually. METHODS: In present randomized control trial, 200 patients were randomly divided in one of the 4 groups using computer-generated tables-control, IV, intraarticular, and combined. We studied evident loss through drain, total loss based on Gross method and hemoglobin balance method, hidden losses, hemoglobin and hematocrit drop, functional scores, and all possible complications related to TXA. RESULTS: Evident loss in combined group was 535.55 mL, not significantly less than IV (585 mL, P = .15) and intraarticular group (514 mL, P = .74). However, these were significantly less than control group (696 mL, P = .000). Functional scores and recovery rates were, however, comparable in all 4 groups. No patients in any group developed symptomatic deep vein thrombosis. CONCLUSION: Tranexamic use decreases blood loss in navigation-assisted arthroplasty, however, less than that observed for conventional arthroplasty in literature. Further, combined group has no added advantage over other methods of drug administration. We believe that additional amount of TXA administered in combined regimen may not be clinically useful. Further TXA group did not have any advantage in terms of functional recovery over control group.


Asunto(s)
Antifibrinolíticos/administración & dosificación , Artroplastia de Reemplazo de Rodilla , Pérdida de Sangre Quirúrgica/prevención & control , Osteoartritis de la Rodilla/cirugía , Hemorragia Posoperatoria/prevención & control , Ácido Tranexámico/administración & dosificación , Administración Intravenosa , Administración Tópica , Anciano , Artroplastia de Reemplazo de Rodilla/métodos , Transfusión Sanguínea , Drenaje , Femenino , Humanos , Inyecciones Intraarticulares , Masculino , Persona de Mediana Edad , Técnicas Estereotáxicas , Cirugía Asistida por Computador
5.
Knee Surg Relat Res ; 28(3): 188-93, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27595071

RESUMEN

PURPOSE: Total knee arthroplasty (TKA) accompanies the risk of bleeding and need for transfusion. There are several methods to reduce postoperative blood loss and blood transfusion. One such method is using tranexamic acid during TKA. The purpose of this study was to confirm whether tranexamic acid reduces postoperative blood loss and blood transfusion after TKA. MATERIALS AND METHODS: A total of 100 TKA patients were included in the study. The tranexamic acid group consisted of 50 patients who received an intravenous injection of tranexamic acid. The control included 50 patients who received a placebo injection. The amounts of drainage, postoperative hemoglobin, and transfusion were compared between the groups. RESULTS: The mean amount of drainage was lower in the tranexamic acid group (580.6±355.0 mL) than the control group (886.0±375.5 mL). There was a reduction in the transfusion rate in the tranexamic acid group (48%) compared with the control group (64%). The hemoglobin level was higher in the tranexamic acid group than in the control group at 24 hours postoperatively. The mean units of transfusion were smaller in the tranexamic acid group (0.76 units) than in the control group (1.28 units). CONCLUSIONS: Our data suggest that intravenous injection of tranexamic acid decreases the total blood loss and transfusion after TKA.

6.
Orthopedics ; 39(3 Suppl): S83-7, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27219736

RESUMEN

Patient-specific instrumentation (PSI) was developed to improve the accuracy of component positioning through custom cutting blocks constructed based on preoperative 3-dimensional imaging in total knee arthroplasty (TKA). The purpose of this study was to compare the clinical and radiological outcomes between the patients who underwent PSI-assisted TKA or conventional TKA. Sixty-four patients (64 knees) underwent TKA by a single surgeon: 32 patients (32 knees) underwent TKA with PSI, 32 patients (32 knees) underwent TKA with conventional instrumentation. The mean age of the patients was 67.6 years, and the mean follow-up duration is 26.2 months. Patients were evaluated preoperatively and after surgery. The current authors evaluated clinical outcomes including knee range of motion, Hospital for Special Survey scale, Western Ontario and McMaster University Osteoarthritis Index, and Knee Society pain and function scores. The current authors also compared radiological outcomes including mechanical axis and coronal and sagittal alignment. The current authors found no significant differences in any clinical outcomes between the PSI-assisted TKA group and the conventional TKA group. In terms of radiological outcomes, the PSI-assisted TKA group had fewer alignment outliers. The current authors found that PSI-assisted TKA restores limb alignment better than conventional TKA, but PSI does not confer a substantial advantage in early functional outcomes after TKA. Further follow-up is needed to ascertain the long-term impact of these findings. [Orthopedics. 2016; 39(3):S83-S87.].


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Artropatías/cirugía , Articulación de la Rodilla/cirugía , Cirugía Asistida por Computador/instrumentación , Anciano , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
7.
Clin Orthop Surg ; 8(1): 45-8, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26929798

RESUMEN

BACKGROUND: Tibial tuberosity-trochlear groove (TT-TG) distance is important in the assessment and treatment of patellofemoral disorders. However, normal and pathological TT-TG values have not been established in Koreans. The purpose of this study was to evaluate the TT-TG distance in the Korean population using lower leg rotational profile computed tomography (CT) scans. METHODS: One hundred rotational profile CT scans were retrospectively collected from patients without knee joint problems aged between 25 to 82 years. TT-TG distances were measured, and statistical analysis was performed. Each CT scan was measured twice in a blinded, randomized manner by three reviewers. Patients with pre-existing knee joint problems were excluded from the study; hence 15 of the 100 patients were excluded because of deformity or unreadable CT scans. Thus, 85 of the 100 patients were included in the study. RESULTS: Interobserver and intraobserver reliability of TT-TG distance measurements was good. The median TT-TG distance for this Korean population was 11.24 mm (mean, 10.24 ± 0.8 mm). TT-TG distance measured nearly 2 mm less on rotational profile CT scans. CONCLUSIONS: Some of the TT-TG distances on rotational profile CT scans were significantly correlated, indicating that they could be accepted. Furthermore, the values on CT scans showed good reliability. In this study, the TT-TG distance in normal Korean people was approximately 10.24 mm without significant differences in TT-TG values between genders.


Asunto(s)
Fémur/anatomía & histología , Fémur/diagnóstico por imagen , Tibia/anatomía & histología , Tibia/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Pierna/anatomía & histología , Pierna/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Valores de Referencia , República de Corea , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA