1.
Spine (Phila Pa 1976) ; 28(3): 239-45, 2003 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-12567024

RESUMEN

STUDY DESIGN: This biomechanical study used flexibility testing on fresh-frozen human cadaveric specimens (occiput to C3) and compared the range of motion and neutral zone for three occipitocervical fixation techniques. OBJECTIVES: To contrast the stabilization provided by a new technique of anterior occipitocervical screw fixation with two other commonly used posterior occipitocervical fixation techniques. SUMMARY OF BACKGROUND DATA: There are no published reports describing this novel technique of anterior occipitocervical screw fixation. METHODS: Six human occipitocervical spine specimens were mounted in a custom-designed, spine-testing machine that applied a pure moment in flexion-extension, lateral bending, and axial rotation. The specimens were tested intact, after an odontoid osteotomy with capsular injury, and after each of three fixation methods: posterior wiring, posterior plate fixation with C1-C2 transarticular screws, and finally with anterior occipitocervical screws. Intervertebral motion was measured with an optoelectronic measurement system, and the range of motion and neutral zone were the kinematic variables measured and used for analysis. RESULTS: In flexion and extension testing, the posterior plate with transarticular screws provided greater stabilization than posterior wiring or anterior occipitocervical screws. In lateral bending and rotation, the anterior screws were similarly effective to the posterior plate, both of which were more effective than posterior wiring. CONCLUSION: The anterior screw fixation technique was as effective as a posterior plate with transarticular screws in stabilizing between the occiput and C2 in axial rotation and lateral bending. In extension and flexion, the anterior screw technique was not as effective as a posterior plate with transarticular screws in providing stability.


Asunto(s)
Vértebra Cervical Axis/cirugía , Tornillos Óseos , Hueso Occipital/cirugía , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Vértebra Cervical Axis/diagnóstico por imagen , Fenómenos Biomecánicos , Cadáver , Humanos , Fijadores Internos , Ensayo de Materiales , Hueso Occipital/diagnóstico por imagen , Docilidad , Rango del Movimiento Articular/fisiología , Rotación , Tomografía Computarizada por Rayos X , Soporte de Peso/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA