Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur Radiol ; 30(2): 934-942, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31471752

RESUMEN

OBJECTIVES: To evaluate the accuracy and clinical integrability of a comprehensive simulation tool to plan and predict radiofrequency ablation (RFA) zones in liver tumors. METHODS: Forty-five patients with 51 malignant hepatic lesions of different origins were included in a prospective multicenter trial. Prior to CT-guided RFA, all patients underwent multiphase CT which included acquisitions for the assessment of liver perfusion. These data were used to generate a 3D model of the liver. The intra-procedural position of the RFA probe was determined by CT and semi-automatically registered to the 3D model. Size and shape of the simulated ablation zones were compared with those of the thermal ablation zones segmented in contrast-enhanced CT images 1 month after RFA; procedure time was compared with a historical control group. RESULTS: Simulated and segmented ablation zone volumes showed a significant correlation (ρ = 0.59, p < 0.0001) and no significant bias (Wilcoxon's Z = 0.68, p = 0.25). Representative measures of ablation zone comparison were as follows: average surface deviation (absolute average error, AAE) with 3.4 ± 1.7 mm, Dice similarity coefficient 0.62 ± 0.14, sensitivity 0.70 ± 0.21, and positive predictive value 0.66 ± 0. There was a moderate positive correlation between AAE and duration of the ablation (∆t; r = 0.37, p = 0.008). After adjustments for inter-individual differences in ∆t, liver perfusion, and prior transarterial chemoembolization procedures, ∆t was an independent predictor of AAE (ß = 0.03 mm/min, p = 0.01). Compared with a historical control group, the simulation added 3.5 ± 1.9 min to the procedure. CONCLUSION: The validated simulation tool showed acceptable speed and accuracy in predicting the size and shape of hepatic RFA ablation zones. Further randomized controlled trials are needed to evaluate to what extent this tool might improve patient outcomes. KEY POINTS: • More reliable, patient-specific intra-procedural estimation of the induced RFA ablation zones in the liver may lead to better planning of the safety margins around tumors. • Dedicated real-time simulation software to predict RFA-induced ablation zones in patients with liver malignancies has shown acceptable agreement with the follow-up results in a first prospective multicenter trial suggesting a randomized controlled clinical trial to evaluate potential outcome benefit for patients.


Asunto(s)
Carcinoma Hepatocelular/cirugía , Ablación por Catéter/métodos , Neoplasias Hepáticas/cirugía , Adolescente , Adulto , Anciano , Carcinoma Hepatocelular/patología , Quimioembolización Terapéutica/métodos , Simulación por Computador , Femenino , Humanos , Hígado/patología , Hígado/cirugía , Neoplasias Hepáticas/patología , Masculino , Márgenes de Escisión , Persona de Mediana Edad , Planificación de Atención al Paciente , Estudios Prospectivos , Tomografía Computarizada por Rayos X , Adulto Joven
2.
Contemp Clin Trials Commun ; 8: 25-32, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29696193

RESUMEN

INTRODUCTION: Radio-frequency ablation (RFA) is a promising minimal-invasive treatment option for early liver cancer, however monitoring or predicting the size of the resulting tissue necrosis during the RFA-procedure is a challenging task, potentially resulting in a significant rate of under- or over treatments. Currently there is no reliable lesion size prediction method commercially available. OBJECTIVES: ClinicIMPPACT is designed as multicenter-, prospective-, non-randomized clinical trial to evaluate the accuracy and efficiency of innovative planning and simulation software. 60 patients with early liver cancer will be included at four European clinical institutions and treated with the same RFA system. The preinterventional imaging datasets will be used for computational planning of the RFA treatment. All ablations will be simulated simultaneously to the actual RFA procedure, using the software environment developed in this project. The primary outcome measure is the comparison of the simulated ablation zones with the true lesions shown in follow-up imaging after one month, to assess accuracy of the lesion prediction. DISCUSSION: This unique multicenter clinical trial aims at the clinical integration of a dedicated software solution to accurately predict lesion size and shape after radiofrequency ablation of liver tumors. Accelerated and optimized workflow integration, and real-time intraoperative image processing, as well as inclusion of patient specific information, e.g. organ perfusion and registration of the real RFA needle position might make the introduced software a powerful tool for interventional radiologists to optimize patient outcomes.

3.
Eur Radiol ; 26(8): 2462-70, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26563349

RESUMEN

OBJECTIVES: To evaluate clinical effectiveness and diagnostic efficiency of a navigation device for MR-guided biopsies of focal liver lesions in a closed-bore scanner. METHODS: In 52 patients, 55 biopsies were performed. An add-on MR navigation system with optical instrument tracking was used for image guidance and biopsy device insertion outside the bore. Fast control imaging allowed visualization of the true needle position at any time. The biopsy workflow and procedure duration were recorded. Histological analysis and clinical course/outcome were used to calculate sensitivity, specificity and diagnostic accuracy. RESULTS: Fifty-four of 55 liver biopsies were performed successfully with the system. No major and four minor complications occurred. Mean tumour size was 23 ± 14 mm and the skin-to-target length ranged from 22 to 177 mm. In 39 cases, access path was double oblique. Sensitivity, specificity and diagnostic accuracy were 88 %, 100 % and 92 %, respectively. The mean procedure time was 51 ± 12 min, whereas the puncture itself lasted 16 ± 6 min. On average, four control scans were taken. CONCLUSIONS: Using this navigation device, biopsies of poorly visible and difficult accessible liver lesions could be performed safely and reliably in a closed-bore MRI scanner. The system can be easily implemented in clinical routine workflow. KEY POINTS: • Targeted liver biopsies could be reliably performed in a closed-bore MRI. • The navigation system allows for image guidance outside of the scanner bore. • Assisted MRI-guided biopsies are helpful for focal lesions with a difficult access. • Successful integration of the method in clinical workflow was shown. • Subsequent system installation in an existing MRI environment is feasible.


Asunto(s)
Biopsia con Aguja/métodos , Biopsia Guiada por Imagen/métodos , Neoplasias Hepáticas/diagnóstico , Hígado/patología , Imagen por Resonancia Magnética Intervencional/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
4.
Histol Histopathol ; 31(1): 115-29, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26358289

RESUMEN

BACKGROUND: Radiofrequency ablation (RFA) is a minimal invasive therapeutic option for patients with hepatocellular carcinoma or liver metastases. We investigated RFA-induced cellular changes in the liver of pigs. MATERIAL AND METHODS: Healthy pigs (n=18) were sacrificed between day 0 and 3 months after RFA. The wound healing process was evaluated by computed tomography (CT), chromotrope anilinblue (CAB) staining of large-scale and standard tissue sections. Immunohistochemistry (IHC) for heat shock protein 70, Caspase-3, Ki67, Reelin, Vinculin, Vimentin and α-SMA was perfomed. RESULTS: One day after RFA, CAB staining showed cell damage and massive hyperaemia. All IHC markers were predominantly expressed at the outer borders of the lesion, except Reelin, which was mainly detected in untreated liver regions. By staining for Hsp70, the heat stress during RFA was monitored, which was most distinct 1-2 days after RFA. CT revealed decreased lesion size after one week. Development of a Vimentin and α-SMA positive fibrotic capsule was observed. CONCLUSION: In the early phase signs of cell damage, apoptosis and proliferation are dominant. Reduced expression of Reelin suggests a minor role of hepatic stellate cells in the RFA zone. After one week myofibroblasts become prominent and contribute to the development of the fibrotic capsule. This elucidates the pathophysiology of RFA and could contribute to the future optimization of RFA procedures.


Asunto(s)
Ablación por Catéter , Hígado/lesiones , Cicatrización de Heridas , Animales , Apoptosis , Proliferación Celular , Trastornos de Estrés por Calor/diagnóstico por imagen , Trastornos de Estrés por Calor/patología , Células Estrelladas Hepáticas/diagnóstico por imagen , Células Estrelladas Hepáticas/patología , Hiperemia/diagnóstico por imagen , Hiperemia/patología , Inmunohistoquímica , Hígado/diagnóstico por imagen , Hígado/patología , Miofibroblastos/diagnóstico por imagen , Miofibroblastos/patología , Sus scrofa , Porcinos , Tomografía Computarizada por Rayos X
6.
Sci Rep ; 5: 15373, 2015 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-26482818

RESUMEN

Percutaneous radiofrequency ablation (RFA) is a minimally invasive technique that destroys cancer cells by heat. The heat results from focusing energy in the radiofrequency spectrum through a needle. Amongst others, this can enable the treatment of patients who are not eligible for an open surgery. However, the possibility of recurrent liver cancer due to incomplete ablation of the tumor makes post-interventional monitoring via regular follow-up scans mandatory. These scans have to be carefully inspected for any conspicuousness. Within this study, the RF ablation zones from twelve post-interventional CT acquisitions have been segmented semi-automatically to support the visual inspection. An interactive, graph-based contouring approach, which prefers spherically shaped regions, has been applied. For the quantitative and qualitative analysis of the algorithm's results, manual slice-by-slice segmentations produced by clinical experts have been used as the gold standard (which have also been compared among each other). As evaluation metric for the statistical validation, the Dice Similarity Coefficient (DSC) has been calculated. The results show that the proposed tool provides lesion segmentation with sufficient accuracy much faster than manual segmentation. The visual feedback and interactivity make the proposed tool well suitable for the clinical workflow.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/terapia , Ablación por Catéter , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/terapia , Tomografía Computarizada por Rayos X , Algoritmos , Ablación por Catéter/métodos , Humanos , Aumento de la Imagen , Estudios Retrospectivos , Máquina de Vectores de Soporte , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
7.
Artículo en Inglés | MEDLINE | ID: mdl-26736783

RESUMEN

In this contribution, we present a semi-automatic segmentation algorithm for radiofrequency ablation (RFA) zones via optimal s-t-cuts. Our interactive graph-based approach builds upon a polyhedron to construct the graph and was specifically designed for computed tomography (CT) acquisitions from patients that had RFA treatments of Hepatocellular Carcinomas (HCC). For evaluation, we used twelve post-interventional CT datasets from the clinical routine and as evaluation metric we utilized the Dice Similarity Coefficient (DSC), which is commonly accepted for judging computer aided medical segmentation tasks. Compared with pure manual slice-by-slice expert segmentations from interventional radiologists, we were able to achieve a DSC of about eighty percent, which is sufficient for our clinical needs. Moreover, our approach was able to handle images containing (DSC=75.9%) and not containing (78.1%) the RFA needles still in place. Additionally, we found no statistically significant difference (p<;0.423) between the segmentation results of the subgroups for a Mann-Whitney test. Finally, to the best of our knowledge, this is the first time a segmentation approach for CT scans including the RFA needles is reported and we show why another state-of-the-art segmentation method fails for these cases. Intraoperative scans including an RFA probe are very critical in the clinical practice and need a very careful segmentation and inspection to avoid under-treatment, which may result in tumor recurrence (up to 40%). If the decision can be made during the intervention, an additional ablation can be performed without removing the entire needle. This decreases the patient stress and associated risks and costs of a separate intervention at a later date. Ultimately, the segmented ablation zone containing the RFA needle can be used for a precise ablation simulation as the real needle position is known.


Asunto(s)
Técnicas de Ablación/instrumentación , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/cirugía , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Agujas , Ondas de Radio , Algoritmos , Humanos , Recurrencia , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA