Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Osteoarthritis Cartilage ; 29(3): 423-432, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33359249

RESUMEN

OBJECTIVE: To assess the potential of near-infrared spectroscopy (NIRS) for in vivo arthroscopic monitoring of cartilage defects. METHOD: Sharp and blunt cartilage grooves were induced in the radiocarpal and intercarpal joints of Shetland ponies and monitored at baseline (0 weeks) and at three follow-up timepoints (11, 23, and 39 weeks) by measuring near-infrared spectra in vivo at and around the grooves. The animals were sacrificed after 39 weeks and the joints were harvested. Spectra were reacquired ex vivo to ensure reliability of in vivo measurements and for reference analyses. Additionally, cartilage thickness and instantaneous modulus were determined via computed tomography and mechanical testing, respectively. The relationship between the ex vivo spectra and cartilage reference properties was determined using convolutional neural network. RESULTS: In an independent test set, the trained networks yielded significant correlations for cartilage thickness (ρ = 0.473) and instantaneous modulus (ρ = 0.498). These networks were used to predict the reference properties at baseline and at follow-up time points. In the radiocarpal joint, cartilage thickness increased significantly with both groove types after baseline and remained swollen. Additionally, at 39 weeks, a significant difference was observed in cartilage thickness between controls and sharp grooves. For the instantaneous modulus, a significant decrease was observed with both groove types in the radiocarpal joint from baseline to 23 and 39 weeks. CONCLUSION: NIRS combined with machine learning enabled determination of cartilage properties in vivo, thereby providing longitudinal evaluation of post-intervention injury development. Additionally, radiocarpal joints were found more vulnerable to cartilage degeneration after damage than intercarpal joints.


Asunto(s)
Articulaciones del Carpo/diagnóstico por imagen , Enfermedades de los Cartílagos/diagnóstico por imagen , Cartílago Articular/diagnóstico por imagen , Aprendizaje Automático , Redes Neurales de la Computación , Espectroscopía Infrarroja Corta , Articulación de la Muñeca/diagnóstico por imagen , Animales , Artroscopía , Enfermedades de los Cartílagos/patología , Cartílago Articular/lesiones , Cartílago Articular/patología , Caballos , Tamaño de los Órganos
2.
Osteoarthritis Cartilage ; 27(10): 1481-1490, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31276818

RESUMEN

OBJECTIVE: To investigate the potential of quantitative susceptibility mapping (QSM) and T2* relaxation time mapping to determine mechanical and structural properties of articular cartilage via univariate and multivariate analysis. METHODS: Samples were obtained from a cartilage repair study, in which surgically induced full-thickness chondral defects in the stifle joints of seven Shetland ponies caused post-traumatic osteoarthritis (14 samples). Control samples were collected from non-operated joints of three animals (6 samples). Magnetic resonance imaging (MRI) was performed at 9.4 T, using a 3-D multi-echo gradient echo sequence. Biomechanical testing, digital densitometry (DD) and polarized light microscopy (PLM) were utilized as reference methods. To compare MRI parameters with reference parameters (equilibrium and dynamic moduli, proteoglycan content, collagen fiber angle and -anisotropy), depth-wise profiles of MRI parameters were acquired at the biomechanical testing locations. Partial least squares regression (PLSR) and Spearman's rank correlation were utilized in data analysis. RESULTS: PLSR indicated a moderate-to-strong correlation (ρ = 0.49-0.66) and a moderate correlation (ρ = 0.41-0.55) between the reference values and T2* relaxation time and QSM profiles, respectively (excluding superficial-only results). PLSR correlations were noticeably higher than direct correlations between bulk MRI and reference parameters. 3-D parametric surface maps revealed spatial variations in the MRI parameters between experimental and control groups. CONCLUSION: Quantitative parameters from 3-D multi-echo gradient echo MRI can be utilized to predict the properties of articular cartilage. With PLSR, especially the T2* relaxation time profile appeared to correlate with the properties of cartilage. Furthermore, the results suggest that degeneration affects the QSM-contrast in the cartilage. However, this change in contrast is not easy to quantify.


Asunto(s)
Cartílago Articular/patología , Cartílago Articular/fisiopatología , Osteoartritis/patología , Osteoartritis/fisiopatología , Animales , Fenómenos Biomecánicos , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/lesiones , Modelos Animales de Enfermedad , Susceptibilidad a Enfermedades , Femenino , Caballos , Imagen por Resonancia Magnética , Masculino , Osteoartritis/diagnóstico por imagen , Osteoartritis/etiología
3.
Osteoarthritis Cartilage ; 27(8): 1235-1243, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31026649

RESUMEN

OBJECTIVE: To investigate the feasibility of near-infrared (NIR) spectroscopy (NIRS) for evaluation of human articular cartilage biomechanical properties during arthroscopy. DESIGN: A novel arthroscopic NIRS probe designed in our research group was utilized by an experienced orthopedic surgeon to measure NIR spectra from articular cartilage of human cadaver knee joints (ex vivo, n = 18) at several measurement locations during an arthroscopic surgery. Osteochondral samples (n = 265) were extracted from the measurement sites for reference analysis. NIR spectra were remeasured in a controlled laboratory environment (in vitro), after which the corresponding cartilage thickness and biomechanical properties were determined. Hybrid multivariate regression models based on principal component analysis and linear mixed effects modeling (PCA-LME) were utilized to relate cartilage in vitro spectra and biomechanical properties, as well as to account for the spatial dependency. Additionally, a k-nearest neighbors (kNN) classifier was employed to reject outlying ex vivo NIR spectra resulting from a non-optimal probe-cartilage contact. Model performance was evaluated for both in vitro and ex vivo NIR spectra via Spearman's rank correlation (ρ) and the ratio of performance to interquartile range (RPIQ). RESULTS: Regression models accurately predicted cartilage thickness and biomechanical properties from in vitro NIR spectra (Model: 0.77 ≤ ρ ≤ 0.87, 2.03 ≤ RPIQ ≤ 3.0; Validation: 0.74 ≤ ρ ≤ 0.84, 1.87 ≤ RPIQ ≤ 2.90). When predicting cartilage properties from ex vivo NIR spectra (0.33 ≤ ρ ≤ 0.57 and 1.02 ≤ RPIQ ≤ 2.14), a kNN classifier enhanced the accuracy of predictions (0.52 ≤ ρ ≤ 0.87 and 1.06 ≤ RPIQ ≤ 1.88). CONCLUSION: Arthroscopic NIRS could substantially enhance identification of damaged cartilage by enabling quantitative evaluation of cartilage biomechanical properties. The results demonstrate the capacity of NIRS in clinical applications.


Asunto(s)
Artroscopía , Cartílago Articular/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Espectroscopía Infrarroja Corta , Anciano , Cadáver , Cartílago Articular/cirugía , Estudios de Factibilidad , Femenino , Humanos , Articulación de la Rodilla/cirugía , Masculino , Análisis de Componente Principal , Análisis de Regresión
4.
Int J Cosmet Sci ; 40(2): 134-140, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29314077

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the performance of a hand-held indentation device for fast and reliable determination of skin stiffness. METHODS: Device accuracy to indentation depths of 0.6 and 1.3 mm was first evaluated on plastic foam materials with mechanical properties verified by a laboratory material testing device. Subsequently, the device's sensitivity to detect age-related changes in skin stiffness was evaluated among 46 healthy women (18-79 years). Finally, the reproducibility of the method was tested with six healthy subjects. RESULTS: High correlation was detected between indentation stiffness of reference material and Young's modulus determined with mechanical testing device (0.6 mm indenter: r = 0.97, P = 0.05; 1.3 mm indenter: r = 0.98, P = 0.04). Age-related decrease of 38% in skin stiffness was observed in healthy volunteers (P < 0.05). The coefficient of variation for 0.6 and 1.3 mm indenters was 7.4% and 8.5%, respectively. No trend related to hysteresis effect was observed from repeated measurements. CONCLUSIONS: The presented indentation technique was accurate against the laboratory material testing device. Furthermore, skin changes related to ageing could be detected with the indentation technique. The new device was found to be feasible for monitoring skin stiffness in cosmetics and clinical conditions.


Asunto(s)
Elasticidad , Ensayo de Materiales/instrumentación , Fenómenos Fisiológicos de la Piel , Adolescente , Adulto , Anciano , Femenino , Antebrazo/fisiología , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Adulto Joven
6.
Equine Vet J ; 49(4): 552-555, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27592527

RESUMEN

BACKGROUND: Arthroscopic optical coherence tomography (OCT) is a promising tool for the detailed evaluation of articular cartilage injuries. However, OCT-based articular cartilage scoring still relies on the operator's visual estimation. OBJECTIVES: To test the hypothesis that semi-automated International Cartilage Repair Society (ICRS) scoring of chondral lesions seen in OCT images could enhance intra- and interobserver agreement of scoring and its accuracy. STUDY DESIGN: Validation study using equine cadaver tissue. METHODS: Osteochondral samples (n = 99) were prepared from 18 equine metacarpophalangeal joints and imaged using OCT. Custom-made software was developed for semi-automated ICRS scoring of cartilage lesions on OCT images. Scoring was performed visually and semi-automatically by five observers, and levels of inter- and intraobserver agreement were calculated. Subsequently, OCT-based scores were compared with ICRS scores based on light microscopy images of the histological sections of matching locations (n = 82). RESULTS: When semi-automated scoring of the OCT images was performed by multiple observers, mean levels of intraobserver and interobserver agreement were higher than those achieved with visual OCT scoring (83% vs. 77% and 74% vs. 33%, respectively). Histology-based scores from matching regions of interest agreed better with visual OCT-based scoring than with semi-automated OCT scoring; however, the accuracy of the software was improved by optimising the threshold combinations used to determine the ICRS score. MAIN LIMITATIONS: Images were obtained from cadavers. CONCLUSIONS: Semi-automated scoring software improved the reproducibility of ICRS scoring of chondral lesions in OCT images and made scoring less observer-dependent. The image analysis and segmentation techniques adopted in this study warrant further optimisation to achieve better accuracy with semi-automated ICRS scoring. In addition, studies on in vivo applications are required.


Asunto(s)
Enfermedades de los Cartílagos/veterinaria , Cartílago Articular/patología , Enfermedades de los Caballos/patología , Tomografía de Coherencia Óptica/veterinaria , Animales , Enfermedades de los Cartílagos/patología , Caballos , Reproducibilidad de los Resultados , Tomografía de Coherencia Óptica/métodos
7.
Osteoarthritis Cartilage ; 25(5): 790-798, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-27965140

RESUMEN

OBJECTIVE: We investigate the potential of a prototype multimodality arthroscope, combining ultrasound, optical coherence tomography (OCT) and arthroscopic indentation device, for assessing cartilage lesions, and compare the reliability of this approach with conventional arthroscopic scoring ex vivo. DESIGN: Areas of interest (AIs, N = 43) were selected from equine fetlock joints (N = 5). Blind-coded AIs were independently scored by two equine surgeons employing International Cartilage Repair Society (ICRS) scoring system via conventional arthroscope and multimodality arthroscope, in which high-frequency ultrasound and OCT catheters were attached to an arthroscopic indentation device. In addition, cartilage stiffness was measured with the indentation device, and lesions in OCT images scored using custom-made automated software. Measurements and scorings were performed twice in two separate rounds. Finally, the scores were compared to histological ICRS scores. RESULTS: OCT and arthroscopic examinations showed the highest average agreements (55.2%) between the scoring by surgeons and histology scores, whereas ultrasound had the lowest (50.6%). Average intraobserver agreements of surgeons and interobserver agreements between rounds were, respectively, for conventional arthroscope (68.6%, 69.8%), ultrasound (68.6%, 68.6%), OCT (65.1%, 61.7%) and automated software (65.1%, 59.3%). CONCLUSIONS: OCT imaging supplemented with the automated software provided the most reliable lesion scoring. However, limited penetration depth of light limits the clinical potential of OCT in assessing human cartilage thickness; thus, the combination of OCT and ultrasound could be optimal for reliable diagnostics. Present findings suggest imaging and quantitatively analyzing the entire articular surface to eliminate surgeon-related variation in the selection of the most severe lesion to be scored.


Asunto(s)
Cartílago Articular/patología , Traumatismos de los Pies/diagnóstico por imagen , Articulaciones del Pie/diagnóstico por imagen , Imagen Multimodal/métodos , Animales , Artroscopía/métodos , Cadáver , Cartílago Articular/diagnóstico por imagen , Finlandia , Articulaciones del Pie/patología , Caballos , Puntaje de Gravedad del Traumatismo , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Tomografía de Coherencia Óptica/métodos , Ultrasonografía Doppler/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA