RESUMEN
BACKGROUND/AIM: This study assessed the epidemiology of luxation injuries with or without dental fractures in patients attending the outpatient clinic of a Brazilian dental school over the past decade. MATERIAL AND METHODS: We reviewed clinical records from a specialized center for dental trauma care in Brazil, focusing on patients who experienced at least one traumatic dental injury (TDI) in a permanent tooth between 2012 and 2022. The extracted data included sex, age, etiology, time between trauma occurrence and the search for initial care, TDI classification, and the need for endodontic treatment. The statistical analysis involved Pearson's chi-squared and Fisher's exact tests at a 5% significance level. RESULTS: The 366 analyzed clinical records included 166 patients (350 teeth) with luxation injuries. Men (n = 102) showed a higher prevalence of luxation injuries than women (n = 64). Extrusive luxation prevailed (n = 99 patients and 208 teeth). Patients with luxation injuries sought care promptly after dental trauma incidents (p = .02) and demonstrated a higher incidence of endodontic treatment (p < .0001) than those without luxation injuries. Lateral luxation was notably associated with traffic accidents (p < .0001). The combination of luxation injuries and tooth fractures did not correlate with a higher need for endodontic treatment (p > .05). CONCLUSIONS: Age and trauma etiology seemed to have influenced the epidemiological profile of luxation injuries. Additionally, these injuries affected the time to seek initial care and the need for endodontic treatment.
RESUMEN
ABSTRACT This report presents the case of an adult patient with mental and intellectual limitations, whose main complaint was dental aesthetics. Dental treatment was performed at the Piracicaba Dental School and approved by the Ethics Committee (CAAE: 65752322.2.0000.5418). Clinically, the patient had inadequacies in the dental arrangement, with periodontal involvement that put the dental elements at risk. In intraoral clinical aspects, the deficiency was identified as maxillary atresia. The buccolingual inclination of the mandibular anterior teeth highlighted the severe crowding and anterior crossing of these teeth. Dental treatment was carried out aiming at the remission of periodontal and orthodontic problems in an integrated manner and with approaches that allowed greater interaction, participation, and patient compliance during treatment. Supra and subgingival scrapings and extraction of the upper left lateral incisor were performed. After three months of periodontal treatment, orthodontic treatment was started with fixed orthodontic appliances. The main objective was to level and align the teeth in both arches to achieve better aesthetic and functional conditions. Due to the COVID-19 pandemic, treatment has been discontinued. This resulted in the regression of the results obtained, including regarding self-care. People with disabilities require dental care with specific strategies for their needs, which must be carried out by a multidisciplinary team. Despite the access limitation imposed by the pandemic, the patient reestablished his motivation to restart treatment, which was facilitated by the bond of trust established between him and the team.
RESUMO Este relato apresenta o caso de um paciente adulto com limitações mentais e intelectuais, cuja queixa principal era a estética dental. O tratamento odontológico foi realizado na Faculdade de Odontologia de Piracicaba e aprovado pelo Comitê de Ética (CAAE: 65752322.2.0000.5418). Clinicamente, o paciente apresentava inadequações no arranjo dentário, com comprometimento periodontal, que colocava em risco os elementos dentais. Nos aspectos clínicos intrabucais, a deficiência foi identificada como atresia maxilar. A inclinação vestíbulo-lingual dos dentes anteriores inferiores destacou o apinhamento severo e o cruzamento anterior desses dentes. O tratamento odontológico foi realizado visando à remissão dos problemas periodontais e ortodônticos de forma integrada e com abordagens que permitissem maior interação, participação e adesão do paciente durante o tratamento. Foram realizadas raspagens supra e subgengivais e extração do incisivo lateral superior esquerdo. Após três meses de tratamento periodontal, iniciou-se o tratamento ortodôntico com aparelhos ortodônticos fixos. O objetivo principal foi nivelar e alinhar os dentes em ambas as arcadas para alcançar melhores condições estéticas e funcionais. Devido à pandemia de COVID-19, o tratamento foi interrompido. Isso resultou na regressão dos resultados obtidos, inclusive quanto ao autocuidado. As pessoas com deficiência requerem atendimento odontológico com estratégias específicas para suas necessidades, que devem ser realizadas por uma equipe multidisciplinar. Apesar da limitação de acesso imposta pela pandemia, o paciente restabeleceu sua motivação para reiniciar o tratamento, o que foi facilitado pelo vínculo de confiança estabelecido entre ele e a equipe.
RESUMEN
The aim of this study was to quantify the force exerted by tandem archwires in a specific system of passive self-ligating bracket. Forty-eight thermo-activated nickel-titanium orthodontic archwires were separated into four groups (n = 12): G1 - two .014" + .014" round archwires; G2 - two .014" + .016" round archwires; G3 - .014" x .025" rectangular archwire; and. G4 - .016" x .022" rectangular archwire. Brackets were fixed onto teeth 1.5 to 2.5 using a device that represented the upper teeth, maintaining an interbracket distance of 6.0 mm. The deflection tests were performed using the structure representative of tooth 1.1 as support on the Instron testing machine at a speed of 2.0 mm/min. The archwires were evaluated at deflections of 0.5 mm, 1.0 mm, and 1.5 mm. The data were analyzed by a generalized linear model, considering values at different deflections as repeated measurements in the same experimental unit (α = 0.5%). At 0.5 mm, higher forces were observed in G2 and G3, which did not differ significantly (p > 0.05). The lowest force was observed in G4 (p < 0.05). At 1.0 mm and 1.5 mm, the highest force was observed in G3, followed by G4 and G2 (p < 0.05). The lowest force was observed in G1 (p < 0.05). In general, tandem archwires (same or different calibers) in a specific passive self-ligating bracket exerted lower force when compared with rectangular archwires.
Asunto(s)
Aparatos Ortodóncicos , Proyectos de Investigación , Modelos LinealesRESUMEN
Abstract The aim of this study was to quantify the force exerted by tandem archwires in a specific system of passive self-ligating bracket. Forty-eight thermo-activated nickel-titanium orthodontic archwires were separated into four groups (n = 12): G1 - two .014" + .014" round archwires; G2 - two .014" + .016" round archwires; G3 - .014" x .025" rectangular archwire; and. G4 - .016" x .022" rectangular archwire. Brackets were fixed onto teeth 1.5 to 2.5 using a device that represented the upper teeth, maintaining an interbracket distance of 6.0 mm. The deflection tests were performed using the structure representative of tooth 1.1 as support on the Instron testing machine at a speed of 2.0 mm/min. The archwires were evaluated at deflections of 0.5 mm, 1.0 mm, and 1.5 mm. The data were analyzed by a generalized linear model, considering values at different deflections as repeated measurements in the same experimental unit (α = 0.5%). At 0.5 mm, higher forces were observed in G2 and G3, which did not differ significantly (p > 0.05). The lowest force was observed in G4 (p < 0.05). At 1.0 mm and 1.5 mm, the highest force was observed in G3, followed by G4 and G2 (p < 0.05). The lowest force was observed in G1 (p < 0.05). In general, tandem archwires (same or different calibers) in a specific passive self-ligating bracket exerted lower force when compared with rectangular archwires.
RESUMEN
BACKGROUND/AIM: Dental trauma (DT) occurs frequently in children and adolescents. Therefore, understanding the factors associated with its occurrence in these age groups is important to establish specific preventive measures. The aim of this study was to investigate the relationships of lip coverage, overjet, and open bite to dental trauma in Brazilian children and adolescents. MATERIAL AND METHODS: The review protocol was registered in the PROSPERO database (CRD42020156290) and the bibliographic search was performed in nine electronic databases until July 2020. The studies included were observational, performed in Brazil, with healthy children and adolescents (0-19 years old), and without the restriction of date or language. Two reviewers assessed the individual risk of bias of the eligible studies with a standardized checklist. The meta-analyses were stratified by dentition stage and age range using fixed or random effects, odds ratio (OR) as the effect measure, and 95% confidence interval. The heterogeneity across studies was assessed with the I² test and the GRADE approach assessed the certainty of evidence. RESULTS: The search presented 2493 initial results, from which 55 met the eligibility criteria and were included. Most studies (67%) presented a low risk of bias and were published between 2000 and 2019. Children and adolescents with inadequate lip coverage are 1.86-2.36 times more likely to suffer from DT, while those with increased overjet are 1.94-3.11 times more likely. Children with primary dentitions and anterior open bites are 1.76 (95% CI: 1.20-2.59) times more likely to suffer from DT. The certainty of evidence varied from very low to moderate. CONCLUSIONS: Inadequate lip coverage, increased overjet, and anterior open bite are associated with the occurrence of dental trauma in Brazilian children and adolescents.
Asunto(s)
Maloclusión Clase II de Angle , Maloclusión , Sobremordida , Adolescente , Adulto , Brasil , Niño , Preescolar , Humanos , Lactante , Recién Nacido , Labio , Adulto JovenRESUMEN
This study aimed to investigate the prevalence of dental trauma in Brazilian children and adolescents. A systematic review was conducted considering eight databases: MEDLINE (via PubMed), LILACS, BBO, Scopus, Embase, Web of Science, Open Access Theses and Dissertations, and OpenThesis. Only prevalence studies that used a probabilistic sampling method were included, without restriction on year or language of publication. The JBI critical appraisal tools for prevalence studies were used to assess the individual risk of bias. The individual studies were combined in the meta-analysis using the random-effects model. The heterogeneity between the studies was analyzed by Cochran's Q and the I-square statistics. A meta-regression analysis was performed to evaluate the sources of heterogeneity. The GRADE approach assessed the certainty of evidence across included studies. The search resulted in 2,069 records, of which 36 were included in the study. The eligible studies were published from 2000 to 2021, with a total sample of 40,194 children and adolescents. Most studies (75%) had a low risk of bias. In permanent teeth, the prevalence of dental trauma was 21% (95%CI: 16.0; 26.0) and in deciduous teeth; 35% (95%CI: 26.0; 44.0). The prevalence of dental trauma among boys was higher than among girls for both dentitions. Based on a low certainty, the prevalence of traumatic dental injuries in Brazilian children and adolescents is higher than that found worldwide both in deciduous and permanent teeth. Also, the prevalence of dental trauma among boys is higher than among girls.
Asunto(s)
Bibliometría , Dentición Permanente , Adolescente , Sesgo , Brasil/epidemiología , Niño , Femenino , Humanos , Masculino , PrevalenciaRESUMEN
The purpose of this in vitro study was to evaluate the force decrease of different elastomeric chains after different times: initial, 10 minutes, 1 day, 28 days and after mechanical brushing. Twenty orthodontic elastomeric chains segments were utilized for each commercial brand. Initially, the elastomeric chain of 15mm long were immediate stretched up to 20 mm in an Instron and the force was measured in gf. After all specimens were placed stretched on rectangular acrylic jigs with distance of 20 mm, immersed in deionized water at 37oC for 10 minutes and the force (gf) was measured again. Five test measurements of remaining force were made at the following time intervals: initial, 10 minutes, 1 day, 28 days and mechanical brushing. After 28 days, the acrylic plates with the specimens were adapted in the mechanical brushing machines (MSCT 3) and the elastomeric chains were submitted to mechanical brushing and the force (gf) measure again. The force (gf) was submitted to mixed-model ANOVA and Sidak post-hoc test (α=0.05). A statistically significant reduction in the force was found for all orthodontic elastomeric chain types after 1 day, 28 days and mechanical brushing (p<0.05). Morelli and 3M Unitek elastomeric chains showed significantly higher force than Abzil and GAC (p<0.05) after 1 day, 28 days and mechanical brushing. In conclusion, the force delivered by all elastomeric chains decayed rapidly over time. Morelli and 3M Unitek elastomeric chains consistently had a significantly greater force after mechanic brushing, while GAC the lowest.
Asunto(s)
Elastómeros , Aparatos Ortodóncicos , Elasticidad , Ensayo de Materiales , Estrés Mecánico , Cepillado DentalRESUMEN
Abstract The purpose of this in vitro study was to evaluate the force decrease of different elastomeric chains after different times: initial, 10 minutes, 1 day, 28 days and after mechanical brushing. Twenty orthodontic elastomeric chains segments were utilized for each commercial brand. Initially, the elastomeric chain of 15mm long were immediate stretched up to 20 mm in an Instron and the force was measured in gf. After all specimens were placed stretched on rectangular acrylic jigs with distance of 20 mm, immersed in deionized water at 37oC for 10 minutes and the force (gf) was measured again. Five test measurements of remaining force were made at the following time intervals: initial, 10 minutes, 1 day, 28 days and mechanical brushing. After 28 days, the acrylic plates with the specimens were adapted in the mechanical brushing machines (MSCT 3) and the elastomeric chains were submitted to mechanical brushing and the force (gf) measure again. The force (gf) was submitted to mixed-model ANOVA and Sidak post-hoc test (α=0.05). A statistically significant reduction in the force was found for all orthodontic elastomeric chain types after 1 day, 28 days and mechanical brushing (p<0.05). Morelli and 3M Unitek elastomeric chains showed significantly higher force than Abzil and GAC (p<0.05) after 1 day, 28 days and mechanical brushing. In conclusion, the force delivered by all elastomeric chains decayed rapidly over time. Morelli and 3M Unitek elastomeric chains consistently had a significantly greater force after mechanic brushing, while GAC the lowest.
Resumo O objetivo deste estudo in vitro foi avaliar a redução da força de diferentes cadeias elastoméricas após diferentes tempos: inicial, 10 minutos, 1 dia, 28 dias e após escovação mecânica. Vinte segmentos de cadeias elastoméricas ortodônticas foram utilizadas para cada marca comercial. Inicialmente, a cadeia elastomérica de 15 mm de comprimento foi esticada imediatamente até 20 mm na Instron e a força foi medida em (gf). Após, todas as amostras foram adaptadas esticadas em placas retangulares de acrílico na distância de 20 mm, imersas em água deionizada a 37o C por 10 minutos e a força (gf) foi medida novamente. Cinco medidas de força foram feitas nos seguintes intervalos de tempo: inicial, 10 minutos, 1 dia, 28 dias e após a escovação mecânica. Após 28 dias, as placas de acrílico com as amostras foram adaptadas na máquina de escovação (MSCT 3) e as cadeias elastoméricas foram submetidas a escovação mecânica e a medida de força (gf) novamente. Os dados da força (gf) foram submetidos a ANOVA modelo misto e teste post-hoc de Sidak (α = 0,05). Uma redução estatisticamente significativa na força foi encontrada para todos os tipos de cadeia elastomérica ortodôntica após 1 dia, 28 dias e escovação mecânica (p<0,05). As cadeias elastoméricas Morelli e 3M Unitek apresentaram força significativamente superior em relação a Abzil e GAC (p<0,05) após 1 dia, 28 dias e escovação mecânica. Em conclusão, a força distribuída por todas as cadeias elastoméricas decaiu rapidamente com o tempo. As cadeias elastoméricas Morelli e 3M Unitek consistentemente tiveram uma força significativamente maior após a escovação mecânica, enquanto GAC a mais baixa.
Asunto(s)
Aparatos Ortodóncicos , Elastómeros , Estrés Mecánico , Cepillado Dental , Ensayo de Materiales , ElasticidadRESUMEN
Abstract: This study aimed to investigate the prevalence of dental trauma in Brazilian children and adolescents. A systematic review was conducted considering eight databases: MEDLINE (via PubMed), LILACS, BBO, Scopus, Embase, Web of Science, Open Access Theses and Dissertations, and OpenThesis. Only prevalence studies that used a probabilistic sampling method were included, without restriction on year or language of publication. The JBI critical appraisal tools for prevalence studies were used to assess the individual risk of bias. The individual studies were combined in the meta-analysis using the random-effects model. The heterogeneity between the studies was analyzed by Cochran's Q and the I-square statistics. A meta-regression analysis was performed to evaluate the sources of heterogeneity. The GRADE approach assessed the certainty of evidence across included studies. The search resulted in 2,069 records, of which 36 were included in the study. The eligible studies were published from 2000 to 2021, with a total sample of 40,194 children and adolescents. Most studies (75%) had a low risk of bias. In permanent teeth, the prevalence of dental trauma was 21% (95%CI: 16.0; 26.0) and in deciduous teeth; 35% (95%CI: 26.0; 44.0). The prevalence of dental trauma among boys was higher than among girls for both dentitions. Based on a low certainty, the prevalence of traumatic dental injuries in Brazilian children and adolescents is higher than that found worldwide both in deciduous and permanent teeth. Also, the prevalence of dental trauma among boys is higher than among girls.
Resumo: O estudo buscou investigar a prevalência de trauma dentário em crianças e adolescentes brasileiros. Foi realizada uma revisão sistemática em oito bases de dados: MEDLINE (via PubMed), LILACS, BBO, Scopus, Embase, Web of Science, Open Access Theses and Dissertations e OpenThesis. Foram incluídos apenas estudos de prevalência que usavam métodos de amostragem probabilística, sem limitação de ano ou idioma de publicação. Para avaliar o risco individual de viés, foram utilizadas as ferramentas de avaliação crítica da JBI para estudos de prevalência. Os estudos individuais foram combinados na metanálise com o uso do modelo de efeitos aleatórios. A heterogeneidade entre os estudos foi analisada pelas estatísticas Q de Cochran e I-quadrado. A análise de metarregressão foi realizada para avaliar as fontes de heterogeneidade. A abordagem GRADE avaliou a certeza das evidências entre os estudos incluídos. A busca resultou em 2.069 registros, dos quais 36 foram incluídos no estudo. Os estudos elegíveis foram publicados entre 2000 e 2021, com uma amostra total de 40.194 crianças e adolescentes. A maioria dos estudos (75%) teve baixo risco de viés. Nos dentes permanentes, a prevalência de trauma dentário foi de 21% (IC95%: 16,0; 26,0) e nos dentes decíduos foi de 35% (IC95%: 26,0; 44,0). A prevalência de trauma dentário foi mais alta no sexo masculino que no feminino, para ambas as dentições. Com base na baixa certeza, a prevalência das lesões dentárias traumáticas em crianças e adolescentes brasileiros é mais alta que no resto do mundo, tanto nos dentes decíduos quanto nos permanentes. Além disso, a prevalência de trauma dentário é mais alta em meninos que em meninas.
Resumen: Este estudio tuvo como meta investigar la prevalencia de trauma dental en niños y adolescentes brasileños. Se realizó una revisión sistemática considerando ocho bases de datos: MEDLINE (via PubMed), LILACS, BBO, Scopus, Embase, Web of Science, Open Access Theses and Dissertations y OpenThesis. Solamente se incluyeron estudios de prevalencia que usaron un método de muestreo probabilístico, sin restricción sobre el año o lengua de publicación. Se usó las herramientas de evaluación crítica del JBI para estudios de prevalencia studies para evaluar el riesgo individual de sesgo. Los estudios individuales se combinaron en metaanálisis, usando un modelo de efectos aleatorios. La heterogeneidad entre los estudios se analizó mediante las estadísticas de Cochran Q e I-cuadrado. Se realizó un análisis de meta-regresión para evaluar las fuentes de heterogeneidad. El enfoque GRADE evaluó la certidumbre de evidencia a través de los estudios incluidos. La búsqueda resultó en 2.069 registros, de los cuales treinta y seis se incluyeron en el estudio. Los estudios elegibles se publicaron entre 2000 y 2021, con una muestra total de 40.194 niños y adolescentes. La mayoría de los estudios (75%) tenían un bajo riesgo de sesgo. En los dientes permanentes la prevalencia de trauma dental fue 21% (IC95%: 16,0; 26,0) y en los dientes deciduos la prevalencia de trauma dental fue 35% (IC95%: 26,0; 44,0). La prevalencia trauma dental entre niños fue más alta que entre niñas en ambas denticiones. Basado en una baja certidumbre, la prevalencia de lesiones traumáticas dentales en niños y adolescentes brasileños es más alta que la encontrada en el resto del mundo, tanto en dientes deciduos como en dientes permanentes. Asimismo, la prevalencia de trauma dental entre niños es más alta que entre niñas.
Asunto(s)
Humanos , Masculino , Femenino , Niño , Adolescente , Bibliometría , Dentición Permanente , Brasil/epidemiología , Sesgo , PrevalenciaRESUMEN
This study investigated the influence of water storage (24 h and 6 months), and Transbond XT and Fuji Ortho LC bonding materials on the bond strength of metallic brackets bonded to feldspathic ceramic. Four cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 60 s. Each cylinder received two layers of silane. Metallic brackets were bonded to the cylinders using Transbond XT or Fuji Ortho LC. Light-activation was carried out with 40 s total exposure time using Bluephase G2. Half the specimens for each bonding materials (n=20) were stored in distilled water at 37 °C for 24 h and the other half for 6 months. Shear bond strength testing was performed after storage times at a crosshead speed of 1 mm/min. The adhesive remnant index (ARI) was used to evaluate the amount of adhesive remaining on the ceramic surface at ×8 magnification. Data were subjected to two-way ANOVA and Tukey's test (p<0.05). Transbond XT showed significantly higher bond strength (p<0.05) than Fuji Ortho LC. Significant differences in bond strength (p<0.05) were found when 24 h and 6 months storage times were compared between materials. ARI showed a predominance of score 0 for all groups, and higher scores at 1, 2 and 3 for 24 h storage time. In conclusion, storage time and bonding materials showed significant influence on the bond strength of brackets to ceramic.
Asunto(s)
Cerámica , Recubrimiento Dental Adhesivo , Metales , Soportes Ortodóncicos , Agua/químicaRESUMEN
The objective of this study was to evaluate the effects of different light sources, thermocycling and silane on the bond strength of metallic brackets to ceramic. Cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 60 s. Half of the cylinders (Groups 1 to 4) received two layers of silane. Metallic brackets were bonded to the cylinders using Transbond XT and divided into 8 groups (n=20), according to light source (Radii Plus LED - 40 s; Groups 1, 2, 5 and 6 and XL 2500 halogen light - 40 s; Groups 3, 4, 7 and 8) and experimental conditions with (Groups 2, 4, 6 and 8) without thermocycling (Groups 1, 3, 5 and 7). Shear bond testing was carried out after 24 h of deionized water storage (Groups 1, 3, 5 and 7) and thermocycling (Groups 2, 4, 6 and 8; 7,000 cycles - 5°/55 °C). Date were submitted to three-way ANOVA and Tukey's post hoc test (α=0.05). The Adhesive Remnamt Index (ARI) was evaluated at 8× magnification. The application of silane was effective in increasing the shear bond strength of the brackets to ceramic (p<0.05). Significant difference (p<0.05) on the bond strength was observed between light sources with or without thermocycling. The ARI showed a predominance of scores 0 for all groups, with an increase in scores 1, 2 and 3 for the silane groups. In conclusion, silane improved significantly the shear bond strength of the brackets to ceramic. The thermocycling and light sources influence on the bond strength.
Resumo O objetivo neste estudo foi avaliar o efeito de diferentes fontes de luz, termociclagem e silano na resistência de união de bráquetes metálicos a cerâmica feldspática. Cilindros de cerâmica feldspática foram condicionados com ácido fluorídrico a 10% por 60 s. Metade dos cilindros (Grupos 1 a 4) recebeu duas camadas de silano. Bráquetes metálicos foram colados aos cilindros usando Transbond XT (3M Unitek), formando 8 grupos (n=20), dependendo das fontes de luz usadas para fotoativação (Radii Plus LED - 40s; Grupos 1, 2, 5 e 6 e XL 2500 halógena - 40 s; Grupos 3, 4, 7 e 8), nas condições experimentais com (Grupos 2, 4, 6 e 8) e sem ciclagem térmica (Grupos 1, 3, 5 e 7). O ensaio de resistência ao cisalhamento foi realizado após armazenagem por 24 h em água deionizada (Grupos 1, 3, 5 e 7) ou armazenados e submetidos a ciclagem térmica (Grupos 2, 4, 6 e 8; 7.000 ciclos - 5° e 55° C). Os dados foram submetidos à Análise de Variância de três fatores e teste de Tukey (α=0,05). O Índice de Remanescente Adesivo (IRA) foi avaliado com aumento de 8×. O uso do silano foi efetivo no aumento da resistência de união ao cisalhamento de bráquetes à cerâmica. Diferença significante na resistência de união foi observada entre as fontes de luz, e com ou sem ciclagem térmica. O IRA mostrou predominância de escore 0 para todos os grupos, com aumento de escores 1, 2 e 3 para os grupos com silano. Em conclusão, a aplicação do silano melhorou significativamente a resistência de união ao cisalhamento de bráquete à cerâmica. A ciclagem térmica e as fontes de luz influenciaram a resistência da união.
Asunto(s)
Cerámica , Metales , Resistencia al Corte , Silanos/químicaRESUMEN
Abstract: This study investigated the influence of water storage (24 h and 6 months), and Transbond XT and Fuji Ortho LC bonding materials on the bond strength of metallic brackets bonded to feldspathic ceramic. Four cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 60 s. Each cylinder received two layers of silane. Metallic brackets were bonded to the cylinders using Transbond XT or Fuji Ortho LC. Light-activation was carried out with 40 s total exposure time using Bluephase G2. Half the specimens for each bonding materials (n=20) were stored in distilled water at 37 °C for 24 h and the other half for 6 months. Shear bond strength testing was performed after storage times at a crosshead speed of 1 mm/min. The adhesive remnant index (ARI) was used to evaluate the amount of adhesive remaining on the ceramic surface at ×8 magnification. Data were subjected to two-way ANOVA and Tukey's test (p<0.05). Transbond XT showed significantly higher bond strength (p<0.05) than Fuji Ortho LC. Significant differences in bond strength (p<0.05) were found when 24 h and 6 months storage times were compared between materials. ARI showed a predominance of score 0 for all groups, and higher scores at 1, 2 and 3 for 24 h storage time. In conclusion, storage time and bonding materials showed significant influence on the bond strength of brackets to ceramic.
Resumo: Este estudo investigou a influência da armazenagem em água (24 h e 6 meses) e dos materiais para colagem Transbond XT e Fuji Ortho LCO na resistência da união de bráquetes metálicos fixados a cerâmica feldspática. Quatro cilindros de cerâmica foram condicionados com ácido fluorídrico a 10% por 60 s. Todos os cilindros receberam duas camadas de silano. Bráquetes metálicos foram fixados aos cilindros utilizando os materiais Transbond XT ou Fuji Ortho LC. A fotoativação foi realizada com tempo de exposição total de 40 s utilizando Bluephase G2. Metade das amostras de cada material de colagem (n=20) foi armazenada em água destilada a 37 °C por 24 h e outra metade por 6 meses. O ensaio de resistência da união ao cisalhamento foi realizado após os períodos de armazenagem à velocidade de 1 mm/minuto. O Índice de Remanescente Adesivo (IRA) foi utilizado para avaliar a quantidade de adesivo residual na superfície da cerâmica, em lupa estereoscópica com aumento de 8x. Os dados foram submetidos à Análise de Variância de dois fatores e teste de Tukey (p<0,05). Transbond XT apresentou resistência de união significativamente maior do que Fuji Ortho LC. Diferença significante (p<0,05) na resistência da união foi encontrada entre os períodos de armazenagem, qualquer que fosse o material para colagem. O IRA mostrou predominância de escore 0 para todos os grupos, com aumento de escores 1, 2 e 3 para o período de armazenagem de 24 h. Em conclusão, o período de armazenagem e os materiais de colagem influenciaram significativamente a resistência da união de bráquetes à cerâmica.
Asunto(s)
Cerámica , Recubrimiento Dental Adhesivo , Metales , Soportes Ortodóncicos , Agua/químicaRESUMEN
The objective of this study was to evaluate the effects of different light sources, thermocycling and silane on the bond strength of metallic brackets to ceramic. Cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 60 s. Half of the cylinders (Groups 1 to 4) received two layers of silane. Metallic brackets were bonded to the cylinders using Transbond XT and divided into 8 groups (n=20), according to light source (Radii Plus LED - 40 s; Groups 1, 2, 5 and 6 and XL 2500 halogen light - 40 s; Groups 3, 4, 7 and 8) and experimental conditions with (Groups 2, 4, 6 and 8) without thermocycling (Groups 1, 3, 5 and 7). Shear bond testing was carried out after 24 h of deionized water storage (Groups 1, 3, 5 and 7) and thermocycling (Groups 2, 4, 6 and 8; 7,000 cycles - 5°/55 °C). Date were submitted to three-way ANOVA and Tukey's post hoc test (α=0.05). The Adhesive Remnamt Index (ARI) was evaluated at 8× magnification. The application of silane was effective in increasing the shear bond strength of the brackets to ceramic (p<0.05). Significant difference (p<0.05) on the bond strength was observed between light sources with or without thermocycling. The ARI showed a predominance of scores 0 for all groups, with an increase in scores 1, 2 and 3 for the silane groups. In conclusion, silane improved significantly the shear bond strength of the brackets to ceramic. The thermocycling and light sources influence on the bond strength.
Asunto(s)
Cerámica , Metales , Resistencia al Corte , Silanos/químicaRESUMEN
OBJECTIVE: The purpose of this study was to assess by means of scanning electron microscopy (SEM) the remaining adhesive interface after debonding orthodontic attachments bonded to bovine teeth with the use of hydrophilic and hydrophobic primers under different dental substrate moisture conditions. MATERIAL AND METHODS: Twenty mandibular incisors were divided into four groups (n = 5). In Group I, bracket bonding was performed with Transbond MIP hydrophilic primer and Transbond XT adhesive paste applied to moist substrate, and in Group II a bonding system comprising Transbond XT hydrophobic primer and adhesive paste was applied to moist substrate. Brackets were bonded to the specimens in Groups III and IV using the same adhesive systems, but on dry dental enamel. The images were qualitatively assessed by SEM. RESULTS: The absence of moisture in etched enamel enabled better interaction between bonding materials and the adamantine structure. The hydrophobic primer achieved the worst micromechanical interlocking results when applied to a moist dental structure, whereas the hydrophilic system proved versatile, yielding acceptable results in moist conditions and excellent interaction in the absence of contamination. CONCLUSIONS: The authors assert that the best condition for the application of primers to dental enamel occurs in the absence of moisture.
Asunto(s)
Cementos Dentales/química , Esmalte Dental/química , Etanol/química , Interacciones Hidrofóbicas e Hidrofílicas , Metacrilatos/química , Soportes Ortodóncicos , Cementos de Resina/química , Agua , Animales , Bovinos , Recubrimiento Dental Adhesivo/métodos , Desconsolidación Dental , Incisivo , Mandíbula , Microscopía Electrónica de Rastreo , Propiedades de SuperficieRESUMEN
This article describes the multidisciplinary treatment of an adult patient presenting with Angle Class III malocclusion, alteration of the mandibular position, vertical alveolar bone loss and absence of teeth in the lower posterior region. With advancing age the existence of occlusal interference due to loss of teeth or tooth structure is very common, resulting in periodontal problems due to occlusal trauma. The options for treatment of Class III malocclusion in adolescent and adult patients include compensatory orthodontic treatment in mild to moderate cases and orthognathic surgery for moderate to severe cases. The combination of various dental specialties enabled improvement in the social circumstances of the patient. This can be observed objectively by the final dental relationship and by the skeletal and tegumentary cephalometric comparison between the situation at the beginning and at the end of the treatment. The compensatory treatment performed permitted the successful correction of a Class III malocclusion in the clinical case presented.
Este trabalho descreve o tratamento multidisciplinar de um paciente adulto com má oclusão de Classe III de Angle, alteração postural da mandíbula, perda óssea alveolar vertical e ausência dentária na região póstero-inferior. Com o avanço da idade é muito comum a existência deinterferências oclusais devido à perda de dentes ou de estrutura dentária, resultando em problemas periodontais devidos ao trauma oclusal. As opções de tratamento da má oclusão de Classe III em adolescentes e pacientes adultos incluem tratamento ortodôntico compensatórios emcasos suaves a moderados e cirurgia ortognática para casos moderados a severos. O resultado clínico da interação de diferentes especialidadesodontológicas permitiu uma melhora do aspecto social da paciente, objetivamente pela relação dentária final e pela comparação cefalométricaesquelética e tegumentar entre o início e final de tratamento. O tratamento compensatório realizado possibilitou o sucesso na correção de umamá oclusão de Classe III do caso clínico apresentado.
Asunto(s)
Masculino , Maloclusión de Angle Clase III , Ortodoncia , Planificación de Atención al Paciente , TerapéuticaRESUMEN
Na última década, o uso de mini-implantes ortodônticos ganhou popularidade na área de Ortodontia, e a correta instalação é um ponto crítico para o sucesso da ancoragem esquelética. Um diagnóstico clínico e radiográfico cuidadoso antes da colocação do mesmo é uma necessidade essencial para conseguir atingir o ponto central do septo radicular. A aplicação correta desses procedimentos pré-cirúrgicos deveria evitar os possíveis danos iatrogênicos no ligamento periodontal, raízes, cavidades nasomaxilares, ou mesmo tecidos vasculares importantes. As radiografias periapicais são procedimentos pré-cirúrgicos rápidos e regulares durante as técnicas de inserção dos mini-implantes. Além disso, uma execução correta das técnicas radiográficas de paralelismo podem oferecer imagens radiográficas precisas e úteis, para decidir o local exato para a inserção dos mini-implantes. O objetivo desse trabalho é descrever a aplicação rápida de guias de posicionamento circulares, em conjunto com protocolo de radiografias em paralelismo antes da colocação dos mini-implantes ortodônticos.
In the last decade mini-screws have gained popularity in orthodontics field and a correct placement of mini-screws is a critical point to the success of the skeletal anchorage. A careful clinical and radiographic diagnostic before insertion mini-screw is an essential requirement to achieve the central point of the radicular septum. The correct application of these pre-surgical procedures should avoid possible iatrogenic damages in periodontal ligament, dental roots, nasomaxillary cavities, or even important vascular tissues. As of today, periapical radiographs is a regular pre surgical procedure during mini-screw insertion technique. Nevertheless, accurate execution of the radiographic parallax technique can offer to us useful and precise radiographic images, to decide the right local insertion of mini-screws in to the septum bone. The purpose of this paper is to describe the ¬application of new positioning circular guides in conjunction with a ¬parallax radiographic protocol before placement of orthodontic mini-screws.
Asunto(s)
Protocolos Clínicos , Implantes Dentales , Diagnóstico por Imagen , Métodos de Anclaje en Ortodoncia , Cuidados Preoperatorios , Radiografía Dental/métodos , Radiografía Dental/tendenciasRESUMEN
OBJECTIVE: The purpose of this study was to assess by means of scanning electron microscopy (SEM) the remaining adhesive interface after debonding orthodontic attachments bonded to bovine teeth with the use of hydrophilic and hydrophobic primers under different dental substrate moisture conditions. MATERIAL AND METHODS: Twenty mandibular incisors were divided into four groups (n=5). In Group I, bracket bonding was performed with Transbond MIP hydrophilic primer and Transbond XT adhesive paste applied to moist substrate, and in Group II a bonding system comprising Transbond XT hydrophobic primer and adhesive paste was applied to moist substrate. Brackets were bonded to the specimens in Groups III and IV using the same adhesive systems, but on dry dental enamel. The images were qualitatively assessed by SEM. RESULTS: The absence of moisture in etched enamel enabled better interaction between bonding materials and the adamantine structure. The hydrophobic primer achieved the worst micromechanical interlocking results when applied to a moist dental structure, whereas the hydrophilic system proved versatile, yielding acceptable results in moist conditions and excellent interaction in the absence of contamination. CONCLUSION: The authors assert that the best condition for the application of primers to dental enamel occurs in the absence of moisture.
OBJETIVO: a proposta desse estudo foi avaliar, por meio de microscopia eletrônica de varredura (MEV), a interface adesiva após a descolagem de acessórios ortodônticos, fixados em dentes bovinos com emprego de adesivo hidrofílico e hidrofóbico, em condições distintas de umidade do substrato dentário. MÉTODOS: foram utilizados 20 incisivos inferiores, divididos em quatro grupos (n = 5): Grupo I , empregou-se o sistema de colagem contendo o primer hidrofílico Transbond MIP e a pasta adesiva Transbond XT, aplicados em substrato úmido; Grupo II, empregou-se o sistema de colagem primer hidrofóbico Transbond XT e pasta adesiva em substrato úmido; Grupos III e IV, os braquetes foram colados com os mesmos sistemas de união dos Grupos I e II, porém com esmalte dentário seco. Removidos os acessórios, avaliou-se em MEV, em diferentes magnificações, a interface adesiva e a interação dos sistemas adesivos com o esmalte dentário. As imagens foram avaliadas qualitativamente, observando-se o embricamento mecânico para o adesivo hidrófilo em quaisquer condições de substrato. RESULTADOS: a falta de umidade no esmalte condicionado permitiu uma melhor interação entre os materiais de ligação e a estrutura adamantina. O adesivo hidrofóbico apresentou o pior resultado de interação micromecânica quando aplicado a uma estrutura dentária úmida; já o sistema hidrofílico mostrou-se versátil, obtendo resultados aceitáveis em condições de umidade e excelente interação na ausência de contaminação. CONCLUSÃO: os autores afirmam que a melhor condição do esmalte dentário para a aplicação de primers é com a ausência de umidade.
Asunto(s)
Animales , Bovinos , Cementos Dentales/química , Esmalte Dental/química , Etanol/química , Interacciones Hidrofóbicas e Hidrofílicas , Metacrilatos/química , Soportes Ortodóncicos , Cementos de Resina/química , Agua , Desconsolidación Dental , Recubrimiento Dental Adhesivo/métodos , Incisivo , Mandíbula , Microscopía Electrónica de Rastreo , Propiedades de SuperficieRESUMEN
INTRODUCTION: Preserving the dental enamel structure during removal of orthodontic accessories is a clinician's obligation. Hence the search for an evidence based debonding protocol. OBJECTIVE: to evaluate and compare, by means of scanning electron microscopy (SEM), the effects of four different protocols of bracket debonding and subsequent polishing on enamel surface, and to propose a protocol that minimizes damage to enamel surface. METHODS: Twelve bovine permanent incisors were divided into four groups according to the instrument used for debonding and removal of the adhesive remnant. In groups 1 and 2, brackets were debonded with a straight debonding plier (Ormco Corp., Glendora, California, USA), and in groups 3 and 4, debonding was performed with the instrument Lift-Off (3M Unitek, Monrovia, California, USA). In groups 1 and 3, the adhesive remnant was removed using a long adhesive removing plier (Ormco Corp., Glendora, California, USA) and in groups 2 and 4, residual adhesive was removed with a tungsten carbide bur (Beavers Dental) at high-speed. After each stage of debonding and polishing, enamel surfaces were replicated and electron micrographs were obtained with 50 and 200X magnification. RESULTS: All four protocols of debonding and polishing caused enamel irregularities. CONCLUSION: Debonding brackets with straight debonding plier, removal of adhesive remnant with a tungsten carbide bur and polishing with pumice and rubber cup was found to be the protocol that caused less damage to enamel surface, therefore this protocol is suggested for debonding brackets.
INTRODUÇÃO: a preservação da estrutura de esmalte após a remoção dos acessórios ortodônticos é obrigação do clínico. Portanto, procura-se um protocolo de descolagem com bases científicas. OBJETIVO: objetivou-se avaliar por microscopia eletrônica de varredura (MEV) a influência de quatro protocolos de remoção de braquetes e polimento da superfície do esmalte e propor um protocolo que minimize os danosà superfície do esmalte. MÉTODOS: doze incisivos permanentes bovinos foram divididos em quatro grupos de acordo com os instrumentos utilizados para a descolagem dos braquetes e remoção do remanescente adesivo. Os braquetes foram descolados com o alicate de descolagem reto (Ormco Corp.) nos grupos 1 e 2, e com o instrumento de descolagem Lift-Off (3M Unitek) nos grupos 3 e 4. Os remanescentes adesivos dos grupos 1 e 3 foram removidos com o alicate removedor de resina longo (Ormco Corp.) e dos grupos 2 e 4 com broca de carboneto de tungstênio (Beavers Dental) em alta-rotação. As superfícies, após cada etapa da descolagem e polimento, foram avaliadas em réplicas de resina epóxica e foram obtidas eletromicrografias com aumento de 50 e 200X. RESULTADOS: os quatro protocolos de remoção de acessórios ortodônticos e polimento ocasionaram irregularidades no esmalte. Conclusão: a remoção do braquete com o alicate de descolagem reto, seguido da remoção do remanescente adesivo com broca de carboneto de tungstênio e polimento final com pasta de pedra-pomes foi o procedimento que ocasionou menores danos ao esmalte, sendo o protocolo sugerido para a remoção dos acessórios ortodônticos.
RESUMEN
OBJECTIVE: Bone anchorage is a key factor for the successful management of some malocclusions for it allows the application of continuous forces, decreases treatment time and is independent from patient compliance. METHODS: The goal of this work was to establish a dental model comparison in order to measure the anchorage loss after the initial retraction of upper canines between the two groups. Group A used mini-implants and Group B used Nance button. All patients had two models cast (M1 and M2). The first models were taken on baseline (M1) and the other models were taken after canine retraction (M2). RESULTS: All measurements were pooled and submitted to statistical analysis. In order to verify the inter-examiner systematic error a paired t-test was performed. Dahlberg's formula was used to estimate the casual error. For comparison purposes between Before and After stages, a paired t-test was done. For the comparison between mini-implant and Nance button groups, a Student t-test was applied. All tests adopted a 5% (p<0.05) significance level. CONCLUSION: No statistically significant difference was observed between the two groups when measurements and comparisons to assess molar anchorage loss after canine initial retraction were performed. Two different anchorage systems were applied on dental models (mini-implants and Nance's button) for each group.
OBJETIVO: a ancoragem óssea é fundamental para o sucesso do tratamento de algumas más oclusões, pois permite a aplicação de forças contínuas, diminui o tempo de tratamento e independe da colaboração do paciente. MÉTODOS: o propósito desse trabalho foi comparar, por meio de modelos dentários, a perda de ancoragem após a retração inicial de caninos superiores entre dois grupos. O grupo A utilizou o mini-implante enquanto o grupo B utilizou o Botão de Nance. Para todos os pacientes foram realizados dois modelos (M1 e M2). Os primeiros modelos foram realizados ao início (M1), e os outros ao final da retração inicial de canino (M2). RESULTADOS: todas as medidas foram tabuladas e submetidas à análise estatística. Para verificar o erro sistemático intraexaminador foi utilizado o teste t pareado. Na determinação do erro casual utilizou-se o cálculo de erro proposto por Dahlberg. Para comparação entre as fases Início e Após, foi utilizado o teste t pareado. Para a comparação entre os grupos de mini-implante e Botão de Nance, foi utilizado o teste t de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). CONCLUSÃO: ao se medir e comparar em modelos dentários a perda de ancoragem dos molares após a retração inicial de canino utilizando-se dois sistemas de ancoragem distintos (Mini-implante e Botão de Nance), pôde-se observar a inexistência de diferença estatisticamente significativa entre os dois grupos.
RESUMEN
Objetivo: para o melhor entendimento do profissional quanto à remoção dos fatores etiológicos, à morfologia do substrato dental e ao material restaurador adesivo, na tentativa de aprimorar a qualidade e, consequentemente a longevidade das restaurações, demonstramos uma técnica restauradora em lesões cervicais não cariosas. Material e Método: para a confecção das restaurações em lesões cervicais não cariosas foi confeccionado o retalho de Widman modificado por Ramfjord e a técnica restauradora incremental com resina composta. Resultados: O acompanhamento longitudinal de um ano do presente caso clínico, demonstrou resultados satisfatórios. Conclusão: Para o sucesso restaurador da lesão cervical não cariosa o Cirurgião-Dentista deve identificar sua etiologia, orientar o paciente para a eliminação ou prevenção do fator causal e elaborar um adequado procedimento restaurador.
Objective: For a better professional understanding as the removal of the etiological factors, the morphology of the dental substrate and adhesive restorative material, in an attempt to improve the quality and hence the longevity of restorations, we demonstrate a technique for restoring non-carious cervical lesions. Methods: for making the restorations in non-carious cervical lesions was made a modified Widman flap by Ramfjord and incremental filling technique with composite resin. Results: Longitudinal follow a year of this case report, showed satisfactory results. Conclusion: For the success of restoring non carious cervical lesion the surgeon must identify the etiology, direct the patient to the elimination or prevention of a causal and develop an appropriate restorative procedure.