Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Intervalo de año de publicación
1.
Diagnostics (Basel) ; 14(16)2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39202256

RESUMEN

Most persons with obesity who have undergone gastric bypass surgery present depressive symptoms. Depression and anxiety have been associated with tear film disorders. This study aimed to investigate whether there is a correlation between tear film conditions and depression symptoms in patients subjected to bariatric surgery. The participants completed a Patient Health Questionnaire to detect depression symptoms. The break-up time and Schirmer test were subsequently applied; the measurements were performed three times, and the average time was subsequently recorded. The results revealed that the Schirmer test score and PH-9 score were negatively correlated, but this was not the case for the break-up time test. Depression symptoms may correlate with lower tear production from the principal tear gland, but they may not have the same effect on meibomian gland production in adults undergoing bariatric surgery. In addition to routine control, bariatric surgery patients should be periodically evaluated by an ophthalmologist and/or psychologist who is aware of potential comorbidities. Furthermore, the observed association between depression symptoms and tear deficiencies highlights the importance of further investigations to gain a better understanding of these mechanisms.

2.
Rev. cuba. oftalmol ; 33(3): e734, tab
Artículo en Español | LILACS, CUMED | ID: biblio-1139089

RESUMEN

RESUMEN Objetivo: Comparar la sensibilidad al contraste evaluada en un grupo de mexicanos con diabetes mellitus contra uno sin diabetes como control. Métodos: Un total de 31 voluntarios, 14 participantes con DM con un tiempo de diagnóstico entre 2 y 20 años (sin retinopatía diabética), y 17 en el grupo control iniciaron el estudio; 4 diabéticos y 5 no diabéticos fueron excluidos por no cumplir con los criterios de inclusión. Por lo tanto, los datos analizados fueron de un grupo de 10 diabéticos (52 ± 10 años) y otro de 12 no diabéticos (52 ± 6 años). Se evaluó la sensibilidad al contraste con la cartilla Vector Vision CSV1000E a una distancia de 2,5 metros con una iluminación de 85 cd/m2. Resultados: Un mayor porcentaje de ojos diabéticos alcanzaron un mejor umbral de contraste en 3, 6 y 18 ciclos por grado en comparación con el grupo control. En 12 ciclos por grado solamente en los umbrales 1 y 5. Conclusiones: La sensibilidad al contraste de la población mexicana con diabetes mellitus presenta mejor percepción de contraste en las frecuencias evaluadas que el grupo control(AU)


ABSTRACT Objective: Compare contrast sensitivity as measured in a group of Mexican diabetes mellitus patients versus a control non-diabetic group. Methods: A group of 31 volunteers, 14 participants with DM with a diagnosis time between 2 and 20 years (without diabetic retinopathy), and 17 in the control group started the study; 4 diabetics and 5 non-diabetics were excluded because they did not meet the inclusion criteria. Therefore, the data analyzed were from a group of 10 diabetics (52 ± 10 years) and another of 12 non-diabetics (52 ± 6 years). Contrast sensitivity was evaluated with a Vector Vision CSV1000E chart at a distance of 2.5 meters and a luminance of 85 cd/m2. Results: A higher percentage of diabetic eyes reached a better contrast threshold at 3, 6 and 18 cycles per degree in comparison with the control group. At 12 cycles per degree only at thresholds 1 and 5. Conclusions: Contrast sensitivity in the Mexican population with diabetes mellitus displays better contrast perception at the frequencies evaluated than the control group(AU)


Asunto(s)
Humanos , Visión Ocular , Sensibilidad de Contraste , Diabetes Mellitus/epidemiología , Retinopatía Diabética/etiología
3.
Obes Surg ; 30(5): 2053-2055, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31853863

RESUMEN

Bariatric surgery patients have deficiencies of macro- and micronutrients that may be related to ophthalmic complications, for example consequences on tear film layers (lipid, aqueous, and mucosa). In this work, we associated protein diet and tear film layers in bariatric patients of a Mexican hospital. We measured characteristics of tear film by the Schirmer and tear break up time (TBUT) tests under three different protein percentage diets: 10, 15, and 25%. TBUT values were low in our study, and therefore, bariatric patients may have high possibilities to suffer dry eye or modifications in lipid tear layer. Bariatric patients, additional to the routine control, periodically should have an extensive eye examination.


Asunto(s)
Bariatria , Síndromes de Ojo Seco , Obesidad Mórbida , Dieta , Síndromes de Ojo Seco/etiología , Humanos , Obesidad Mórbida/cirugía , Lágrimas
4.
Rev. cuba. oftalmol ; 31(3): 1-7, jul.-set. 2018. tab
Artículo en Español | CUMED | ID: cum-73508

RESUMEN

Este estudio se propone conocer la ayuda visual mejor aceptada por pacientes de visión baja, para lo cual se realizó una revisión bibliográfica con el fin de contribuir al ejercicio optométrico. Se revisaron un total de 28 artículos del año 2007 a la fecha actual. En las diferentes patologías en estudio se encontró que la ayuda visual mejor aceptada para la visión cercana fueron las lupas, y para la visión lejana eran más usados los telescopios(AU)


The aim of this study is to determine which is the most frequent visual aid use in low vision. Twenty-eight articles were consulted in a period from 2007 until now. It was observed that for near vision the hans spectacles were the best aid and for far vision telescope were more used(AU)


Asunto(s)
Humanos , Baja Visión/etiología , Telescopios , Educación de Personas con Discapacidad Visual/métodos , Conducta de Ayuda , Literatura de Revisión como Asunto , Publicaciones Científicas y Técnicas
5.
Rev. cuba. oftalmol ; 31(3): 1-7, jul.-set. 2018. tab
Artículo en Español | LILACS | ID: biblio-985574

RESUMEN

Este estudio se propone conocer la ayuda visual mejor aceptada por pacientes de visión baja, para lo cual se realizó una revisión bibliográfica con el fin de contribuir al ejercicio optométrico. Se revisaron un total de 28 artículos del año 2007 a la fecha actual. En las diferentes patologías en estudio se encontró que la ayuda visual mejor aceptada para la visión cercana fueron las lupas, y para la visión lejana eran más usados los telescopios(AU)


The aim of this study is to determine which is the most frequent visual aid use in low vision. Twenty-eight articles were consulted in a period from 2007 until now. It was observed that for near vision the hans spectacles were the best aid and for far vision telescope were more used(AU)


Asunto(s)
Humanos , Baja Visión/etiología , Telescopios/estadística & datos numéricos , Educación de Personas con Discapacidad Visual/métodos , Conducta de Ayuda , Literatura de Revisión como Asunto , Publicaciones Científicas y Técnicas
6.
Sensors (Basel) ; 14(11): 21523-34, 2014 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-25405510

RESUMEN

Respiratory and heart rates are among the most important physiological parameters used to monitor patients' health. It is important to design devices that can measure these parameters without risking or altering the subject's health. In this context, a novel sensing method to monitor simultaneously the heartbeat and respiratory rate signals of patients within an electrically safety environment was developed and tested. An optical fiber-based sensor was used in order to detect two optical phenomena. Photo-plethysmography and the relation between bending radius and attenuation of optical fiber were coupled through a single beam light traveling along this fiber.


Asunto(s)
Traumatismos por Electricidad/prevención & control , Tecnología de Fibra Óptica/instrumentación , Frecuencia Cardíaca/fisiología , Seguridad del Paciente , Fotopletismografía/instrumentación , Pruebas de Función Respiratoria/instrumentación , Frecuencia Respiratoria/fisiología , Conductividad Eléctrica , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Procesamiento de Señales Asistido por Computador/instrumentación , Integración de Sistemas , Transductores
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA