Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Emotion ; 15(1): 90-103, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25198783

RESUMEN

According to expectancy-value models of self-regulation, people are motivated to act in ways they expect to be useful to them. For instance, people are motivated to run when they believe running is useful, even when they have nothing to run away from. Similarly, we propose an expectancy-value model of emotion regulation, according to which people are motivated to emote in ways they expect to be useful to them, regardless of immediate contextual demands. For instance, people may be motivated to get angry when they believe anger is useful, even when there is nothing to be angry about. In 5 studies, we demonstrate that leading people to expect an emotion to be useful increased their motivation to experience that emotion (Studies 1-5), led them to up-regulate the experience of that emotion (Studies 3-4), and led to emotion-consistent behavior (Study 4). Our hypotheses were supported when we manipulated the expected value of anxiety (Study 1) and anger (Studies 2-5), both consciously (Studies 1-4) and unconsciously (Study 5). We discuss the theoretical and pragmatic implications of the proposed model.


Asunto(s)
Toma de Decisiones , Emociones , Modelos Psicológicos , Motivación , Ira , Ansiedad/psicología , Femenino , Humanos , Masculino , Caracteres Sexuales , Factores Sexuales , Controles Informales de la Sociedad , Adulto Joven
2.
Emerg Infect Dis ; 12(4): 588-96, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16704806

RESUMEN

Monochloramine disinfection of municipal water supplies is associated with decreased risk for Legionnaires' disease. We conducted a 2-year, prospective, environmental study to evaluate whether converting from chlorine to monochloramine for water disinfection would decrease Legionella colonization of hot water systems. Water and biofilm samples from 53 buildings were collected for Legionella culture during 6 intervals. Prevalence ratios (PRs) comparing Legionella colonization before and after monochloramine disinfection were adjusted for water system characteristics. Legionella colonized 60% of the hot water systems before monochloramine versus 4% after conversion (PR 0.07, 95% confidence interval 0.03-0.16). The median number of colonized sites per building decreased with monochloramine disinfection. Increased prevalence of Legionella colonization was associated with water heater temperatures <50 degrees C, buildings taller than 10 stories, and interruptions in water service. Increasing use of monochloramine in water supplies throughout the United States may reduce Legionella transmission and incidence of Legionnaires' disease.


Asunto(s)
Cloraminas/farmacología , Desinfectantes/farmacología , Legionella/efectos de los fármacos , Microbiología del Agua , Purificación del Agua/métodos , Desinfección/métodos , Humanos , Enfermedad de los Legionarios/epidemiología , Vigilancia de la Población , San Francisco/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA