Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Intervalo de año de publicación
1.
Environ Sci Pollut Res Int ; 29(36): 54842-54854, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35314929

RESUMEN

The objective of the current study is to investigate the natural radioactivity of some building materials, the resulting long-term external and internal effective dose equivalents (EEDE and IEDE) analysis followed by indoor radon measurements, and the assessment of some radiological risk indicators associated with radon exposure. A total of 37 samples of building materials were analyzed with a sodium iodide detector (NaI (Tl)), and the computer code RESRAD-BUILD was used for the analysis of the EEDE and IEDE of the structural elements of the houses (walls and floor). For indoor radon measurements, 140 houses were selected, and in each of them was placed 01 RADTRAK dosimeter. Inhalation dose, total dose, and some radiological risk indicators were calculated. The specific activities of 226Ra, 232Th, and 40K for the overall sampled building materials were found to vary between 10 ± 2-52 ± 7, 10 ± 1-95 ± 10, and 31 ± 1-673 ± 20 Bq kg-1, respectively. The dwelling types with bare brick walls, cement mortar plastered walls, and concrete floors show EEDE and IEDE values well below the recommended limits. The corresponding dwelling type contributions to the measured average indoor radon concentration (42 ± 12 Bq m-3) are 22%, 13%, and 16%, respectively. Inhalation dose resulting from the measured indoor radon concentrations varies from 0.35 to 3.24 mSv y-1 with a mean value of 0.96 ± 0.55 mSv y-1, which represents about 65% of the total dose simulated (1.49 ± 0.88 mSv y-1) by the RESRAD-BUILD code. The overall analysis of indoor radon-related radiological risk indicators shows low levels of risk relative to permissible limits.


Asunto(s)
Contaminantes Radiactivos del Aire , Contaminación del Aire Interior , Monitoreo de Radiación , Radiactividad , Radón , Contaminantes Radiactivos del Aire/análisis , Contaminación del Aire Interior/análisis , Camerún , Materiales de Construcción , Vivienda , Radón/análisis
2.
Radiat Prot Dosimetry ; 181(4): 343-349, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-29534231

RESUMEN

Radon-222, a naturally occurring radioactive gas, responsible together with its progeny of around 50% of the average effective dose received by the population, has not been regulated by law until the recent Directive 2013/51 /Euratom. Its transposition into Spanish legislation was made in the recent RD 314/2016, which sets at limit value of 500 Bq l-1 for radon-222 in water for human consumption. Intercomparison exercises, such as those carried out by IPROMA SL and the Laboratory of Environmental Radioactivity of the Cantabria University (LARUC) in November 2015 and December 2016, represent the most useful tool available for detecting problems and taking corrective actions necessary for an efficient measurement by part of the laboratories. The participants in these exercises used three techniques: liquid scintillation counting, gamma spectrometry and desorption followed by ionisation chamber detection.


Asunto(s)
Monitoreo del Ambiente/métodos , Monitoreo de Radiación/métodos , Radón/análisis , Contaminantes Radiactivos del Agua/análisis , Abastecimiento de Agua , Conteo por Cintilación , España , Espectrometría gamma
3.
J Environ Manage ; 180: 421-32, 2016 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-27266647

RESUMEN

This study deals with the spatiotemporal dynamics of CO2 and its isotopic composition (δ(13)CCO2) in the atmosphere of Altamira Cave (northern Spain) over two annual cycles. In general terms, the cavity shows two distinct ventilation modes, acting as a CO2 reservoir from October to May (recharge stage), while actively exchanging gases with the outside atmosphere between July and September (discharge stage). In recharge mode, the in-cave air shows higher and relatively homogeneous CO2 values (3332 ± 521 ppm) with lower δ(13)CCO2 (-23.2 ± 0.4‰). In contrast, during the discharge stage, the CO2 concentrations are lower and relatively more variable (1383 ± 435 ppm) and accompanied by higher δ(13)CCO2 (up to -12‰). This seasonal pattern is controlled by the distinct rates of exchange of air masses with the external atmosphere through the annual cycle, as well as by changes in the production of CO2 in the soil and natural fluctuations in the concentration of dissolved inorganic carbon transported by drip water into the cave. In contrast to the interpretations of previous studies in Altamira Cave, no local air intakes into the deepest cave sections were flagged by our δ(13)C measurements. This finding is also supported by analyses of CO2 and (222)Rn in air, density of airborne particles and air temperature. In addition, preliminary experiments examining the visitor-produced disturbances on δ(13)CCO2 were conducted during the various cave ventilation stages to explore the potential use of this parameter as an indicator of anthropic pressure in caves. Our data show that visits (overall stay of 60-85 min; i.e., 4 people for 20 min) significantly affected δ(13)CCO2 (up to Δδ(13)C âˆ¼ -2‰) in the Polychrome Hall of Altamira Cave under conditions of low natural CO2 (discharge stage), whereas it remained almost unaltered under circumstances of high CO2 concentration (recharge stage). This demonstrates that δ(13)CCO2 is sensitive to perturbations produced by visitors during certain periods.


Asunto(s)
Contaminantes Atmosféricos/análisis , Dióxido de Carbono/análisis , Cuevas , Atmósfera , Monitoreo del Ambiente , Humanos , España , Temperatura
7.
J Environ Radioact ; 102(4): 378-85, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21382656

RESUMEN

The present paper discusses the results of an empirical study of four approaches to reducing indoor radon concentrations based on depressurization techniques in underground sumps. The experiments were conducted in prototype housing built in an area of Spain where the average radon concentration at a depth of 1 m is 250 kBq m(-3). Sump effectiveness was analysed in two locations: underneath the basement, which involved cutting openings into the foundation, ground storey and roof slabs, and outside the basement walls, which entailed digging a pit alongside the building exterior. The effectiveness of both sumps was likewise tested with passive and forced ventilation methods. The systems proved to be highly efficient, lowering radon levels by 91-99%, except in the solution involving passive ventilation and the outside sump, where radon levels were reduced by 53-55%. At wind speeds of over 8 m/s, however, passive ventilation across an outside sump lowered radon levels by 95% due to a Venturi effect induced drop in pressure.


Asunto(s)
Contaminación del Aire Interior/prevención & control , Contaminación Radiactiva del Aire/prevención & control , Vivienda , Radón/análisis , Ventilación/métodos , Arquitectura , Presión , Monitoreo de Radiación/estadística & datos numéricos , España
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA