Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Clin Imaging ; 36(5): 526-31, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22920357

RESUMEN

PURPOSE: To investigate the diagnostic accuracy of 3.0-T diffusion-weighted imaging (DWI) for detection of prostate cancer by using different b-values. METHODS: Seventy-three patients underwent magnetic resonance imaging (MRI) at 3.0 T. Three MRI sets were reviewed by two radiologists: MRI and DWI (b = 500 s/mm(2)) (protocol A), MRI and DWI (b = 1000 s/mm(2)) (protocol B), and MRI and DWI (b = 2000s/mm(2)) (protocol C). Areas under the receiver operating characteristic curve (AUCs) were calculated. RESULTS: The mean of the AUCs in protocol C was larger than those in protocol A and in protocol B (P<.05). CONCLUSION: DWI (b = 2000s/mm(2)) at 3.0 T can improve the diagnostic accuracy for detection of prostate cancer.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico , Anciano , Biopsia , Diagnóstico Diferencial , Humanos , Masculino , Antígeno Prostático Específico/sangre , Neoplasias de la Próstata/patología , Curva ROC , Estudios Retrospectivos
2.
J Magn Reson Imaging ; 32(5): 1061-7, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21031509

RESUMEN

PURPOSE: To evaluate motion artifacts, tissue contrasts, and lesion detectability in the neck with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) technique. MATERIALS AND METHODS: A total of 46 patients referred for MRI of the neck were included in a comparison of T2-weighted BLADE (T2W-BLADE) sequence and T2W fast spin-echo (T2W-FSE) sequence. All examinations were performed at 3T using the same parameters. Two observers evaluated unlabelled images for motion artifacts, the preferred image quality, and lesion detectability. Region of interest (ROI)-based quantitative measurements were performed to assess tissue contrasts. The frequency of occurrence of the different assessed artifacts and the lesion detectability was tested using McNemar's test. Tissue contrasts were compared using the Wilcoxon paired test. Reader agreement was assessed using kappa test. RESULTS: T2W-BLADE showed less ghosting and pulsation artifacts than T2W-FSE (P < 0.01). T2W-BLADE images were rated as better than or equal to T2W-FSE images in majority cases (93.5%; kappa = 0.64). There was not significant difference in tissue contrasts between T2W-BLADE and T2W-FSE. A total of 32 lesions were present in 32 patients and equally well seen on T2W-BLADE and T2W-FSE. CONCLUSION: T2W-BLADE can reduce motion artifacts and provide tissue contrasts and lesion detectability equivalent to T2W-FSE.


Asunto(s)
Artefactos , Aumento de la Imagen , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/métodos , Cuello/patología , Quistes/diagnóstico , Femenino , Neoplasias de Cabeza y Cuello/diagnóstico , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA