1.
J Mater Sci Mater Med ; 11(11): 751-5, 2000 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15348081

RESUMEN

Hydroxyapatite coating on commercially pure titanium has been produced by a biomimetic method in order to improve osteointegration for medical implant purposes. A specific chemical treatment by etching titanium substrate with different concentrations of NaOH aqueous solution at 130 degrees C in an autoclave, followed by heat treatment at 600 degrees C was selected to obtain an activated titanium substrate. The microporous surface obtained has allowed the nucleation and growth of a calcium phosphate layer by soaking the substrate in a simulated body fluid (SBF). Scanning electron microscopy (SEM) together with energy dispersive analyzer for X-ray (EDS), X-ray diffraction (XRD) as well as Fourier transform infrared spectroscopy (FT-IR) were employed to evaluate the hydroxyapatite coating. A homogeneous structure coating without cracks defined the chemical treatment condition of the substrate.