Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Clin Oral Implants Res ; 21(3): 284-9, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20074243

RESUMEN

AIM: The purpose of this study was to evaluate the survival and success of early-loaded implants placed in the intraforaminal area of the edentulous mandible, and the survival of the implant-supported fixed dental prostheses (FDP). MATERIAL AND METHODS: Thirty-seven patients (18.9% male, mean age 64.5 years) with edentulous lower jaws were treated with implant-supported FDPs in the mandible. One hundred and eighty-five screw-type implants were placed in the intraforaminal area of the symphysis (five implants per patient). Immediately after implant placement, a framework was fabricated and the FDP was manufactured on the framework. Within 2 weeks, the implants were rigidly connected and loaded with the implant-retained FDP. RESULTS: During the 1-8-year observation period (mean 4.5 years), a total of 32 implant-retained complications occurred. Nineteen implants were lost in 10 patients, resulting in a cumulative survival of 89.7%. Nine implants in five patients did not osseointegrate. Although these implants were not removed, because stability within the connective tissue was acceptable and inflammation was absent, they were recorded as unsuccessful. Consequently, the cumulative success declined to 84.9%. Four implants in three patients had clinical signs of periimplantitis (2.2% of all implants). Denture-related complications included one complete failure, when one FDP had to be removed after the last of five implants had been replaced. Furthermore, 10 fractures of the framework occurred in six patients, three FDPs had to be adapted or modified, and the facing of the FDP had to be repaired 16 times in 11 patients. CONCLUSION: Although one-stage early-loaded implants functioned well for most patients with edentulous mandibles, immediate loading is associated with a larger number of implant-related complications than in other studies investigating delayed loading. Because of the substantial prosthetic complications and aftercare, this procedure cannot be generally recommended.


Asunto(s)
Implantación Dental Endoósea/métodos , Prótesis Dental de Soporte Implantado/efectos adversos , Fracaso de la Restauración Dental , Dentadura Completa Inmediata/efectos adversos , Arcada Edéntula/rehabilitación , Análisis del Estrés Dental , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Mandíbula/cirugía , Persona de Mediana Edad , Periodontitis/etiología , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/etiología , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA