Sci Rep ; 14(1): 16058, 2024 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-38992074

RESUMEN

Estimating the tissue parameters of skin tumors is crucial for diagnosis and effective therapy in dermatology and related fields. However, identifying the most sensitive biomarkers require an optimal rheological model for simulating skin behavior this remains an ongoing research endeavor. Additionally, the multi-layered structure of the skin introduces further complexity to this task. In order to surmount these challenges, an inverse problem methodology, in conjunction with signal analysis techniques, is being employed. In this study, a fractional rheological model is presented to enhance the precision of skin tissue parameter estimation from the acquired signal from torsional wave elastography technique (TWE) on skin tumor-mimicking phantoms for lab validation and the estimation of the thickness of the cancerous layer. An exhaustive analysis of the spring-pot model (SP) solved by the finite difference time domain (FDTD) is conducted. The results of experiments performed using a TWE probe designed and prototyped in the laboratory were validated against ultrafast imaging carried out by the Verasonics Research System. Twelve tissue-mimicking phantoms, which precisely simulated the characteristics of skin tissue, were prepared for our experimental setting. The experimental data from these bi-layer phantoms were measured using a TWE probe, and the parameters of the skin tissue were estimated using inverse problem-solving. The agreement between the two datasets was evaluated by comparing the experimental data obtained from the TWE technique with simulated data from the SP- FDTD model using Pearson correlation, dynamic time warping (DTW), and time-frequency representation. Our findings show that the SP-FDTD model and TWE are capable of determining the mechanical properties of both layers in a bilayer phantom, using a single signal and an inverse problem approach. The ultrafast imaging and the validation of TWE results further demonstrate the robustness and reliability of our technology for a realistic range of phantoms. This fusion of the SP-FDTD model and TWE, as well as inverse problem-solving methods has the potential to have a considerable impact on diagnoses and treatments in dermatology and related fields.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Fantasmas de Imagen , Neoplasias Cutáneas , Diagnóstico por Imagen de Elasticidad/métodos , Neoplasias Cutáneas/diagnóstico por imagen , Neoplasias Cutáneas/patología , Humanos , Piel/diagnóstico por imagen , Piel/patología , Reología
3.
Sci Rep ; 14(1): 16461, 2024 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-39013962

RESUMEN

In this work, we present a novel preclinical device utilizing Torsional Wave Elastography (TWE). It comprises a rotational actuator element and a piezoceramic receiver ring circumferentially aligned. Both allow the transmission of shear waves that interact with the tissue before being received. Our main objective is to demonstrate and characterize the reliability, robustness, and accuracy of the device for characterizing the stiffness of elastic materials and soft tissues. Experimental tests are performed using two sets of tissue mimicking phantoms. The first set consists of calibrated CIRS gels with known stiffness value, while the second test uses non-calibrated manufactured phantoms. Our experimental observations show that the proposed device consistently and repeatably quantifies the stiffness of elastic materials with high accuracy. Furthermore, comparison with established techniques demonstrates a very high correlation (> 95%), supporting the potential medical application of this technology. The results obtained pave the way for a cross-sectional study aiming to investigate the correlation between gestational age and cervical elastic properties during pregnancy.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Fantasmas de Imagen , Diagnóstico por Imagen de Elasticidad/métodos , Diagnóstico por Imagen de Elasticidad/instrumentación , Humanos , Reproducibilidad de los Resultados , Femenino , Embarazo , Elasticidad , Diseño de Equipo
4.
Phys Eng Sci Med ; 47(2): 575-587, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38319472

RESUMEN

This paper presents a novel method for reconstructing skin parameters using Probabilistic Inverse Problem (PIP) techniques and Torsional Wave Elastography (TWE) rheological modeling. A comprehensive examination was conducted to compare and analyze the theoretical, time-of-flight (TOF), and full-signal waveform (FSW) approaches. The objective was the identification of the most effective method for the estimation of mechanical parameters. Initially, the most appropriate rheological model for the simulation of skin tissue behavior was determined through the application and comparison of two models, spring pot (SP) and Kevin Voigt fractional derivative (KVFD). A numerical model was developed using the chosen rheological models. The collection of experimental data from 15 volunteers utilizing a TWE sensor was crucial for obtaining significant information for the reconstruction process. The study sample consisted of five male and ten female subjects ranging in age from 25 to 60 years. The procedure was performed on the ventral forearm region of the participants. The process of reconstructing skin tissue parameters was carried out using PIP techniques. The experimental findings were compared with the numerical results. The three methods considered (theoretical, TOF, FSW) have been used. The efficacy of TOF and FSW was then compared with theoretical method. The findings of the study demonstrate that the FSW and TOF techniques successfully reconstructed the parameters of the skin tissue in all of the models. The SP model's the skin tissue η values ranged from 8 to 12 P a · s , as indicated by the TOF reconstruction parameters. η values found by the KVFD model ranged from 4.1 to 9.3 P a · s . The µ values generated by the KVFD model range between 0.61 and 96.86 kPa. However, FSW parameters reveal that skin tissue η values for the SP model ranged from 7.8 to 12 P a · s . The KVFD model determined η values between 6.3 and 9.5 P a · s . The KVFD model presents µ values ranging between 26.02 and 122.19 kPa. It is shown that the rheological model that best describes the nature of the skin is the SP model and its simplicity as it requires only two parameters, in contrast to the three parameters required by the KVFD model. Therefore, this work provides a valuable addition to the area of dermatology, with possible implications for clinical practice.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Piel , Humanos , Femenino , Masculino , Adulto , Piel/diagnóstico por imagen , Persona de Mediana Edad , Biomarcadores/metabolismo , Reología , Modelos Biológicos
5.
Ultrasonics ; 138: 107206, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38008004

RESUMEN

A new reconstruction approach that combines Reverse Time Migration (RTM) and Genetic Algorithms (GAs) is proposed for solving the inverse problem associated with transluminal shear wave elastography. The transurethral identification of the first thermal lesion generated by transrectal High Intensity Focused Ultrasound (HIFU) for the treatment of prostate cancer, was used to preliminarily test in silico the combined reconstruction method. The RTM method was optimised by comparing reconstruction images from several cross-correlation techniques, including a new proposed one, and different device configurations in terms of the number and arrangement of emitters and receivers of the conceptual transurethral probe. The best results were obtained for the new proposed cross-correlation method and a device configuration with 3 emitters and 32 receivers. The RTM reconstructions did not completely contour the shape of the HIFU lesion, however, as planned for the combined approach, the areas in the RTM images with high level of correlation were used to narrow down the search space in the GA-based technique. The GA-based technique was set to find the location of the HIFU lesion and the increment in stiffness and viscosity due to thermal damage. Overall, the combined approach achieves lower level of error in the reconstructed values, and in a shorter computational time, compared to the GA-based technique alone. The lowest errors were accomplished for the location of HIFU lesion, followed by the contrast ratio of stiffness between thermally treated tissue and non-treated normal tissue. The homologous ratio of viscosity obtained higher level of error. Further investigation considering diverse scenarios to be reconstructed and with experimental data is required to fully evaluate the feasibility of the combined approach.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Ultrasonido Enfocado de Alta Intensidad de Ablación , Masculino , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Algoritmos
6.
Phys Eng Sci Med ; 46(4): 1489-1501, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37642939

RESUMEN

Measuring the mechanical nonlinear properties of the cornea remains challenging due to the lack of consensus in the methodology and in the models that effectively predict its behaviour. This study proposed developing a procedure to reconstruct nonlinear fourth-order elastic properties of the cornea based on a mathematical model derived from the theory of Hamilton et al. and using the torsional wave elastography (TWE) technique. In order to validate its diagnostic capability of simulated pathological conditions, two different groups were studied, non-treated cornea samples (n=7), and ammonium hydroxide ([Formula: see text]) treated samples (n=7). All the samples were measured in-plane by a torsional wave device by increasing IOP from 5 to 25 mmHg with 5 mmHg steps. The results show a nonlinear variation of the shear wave speed with the IOP, with higher values for higher IOPs. Moreover, the shear wave speed values of the control group were higher than those of the treated group. The study also revealed significant differences between the control and treated groups for the Lamé parameter [Formula: see text] (25.9-6.52 kPa), third-order elastic constant A (215.09-44.85 kPa), and fourth-order elastic constant D (523.5-129.63 kPa), with p-values of 0.010, 0.024, and 0.032, respectively. These findings demonstrate that the proposed procedure can distinguish between healthy and damaged corneas, making it a promising technique for detecting diseases associated with IOP alteration, such as corneal burns, glaucoma, or ocular hypertension.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Diagnóstico por Imagen de Elasticidad/métodos , Córnea/diagnóstico por imagen
7.
Ultrasonics ; 132: 107021, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37141701

RESUMEN

The propagation of shear waves in elastography at high frequency (>3 kHz) in viscoelastic media has not been extensively studied due to the high attenuation and technical limitations of current techniques. An optical micro-elastography (OME) technique using magnetic excitation for generating and tracking high frequency shear waves with enough spatial and temporal resolution was proposed. Ultrasonics shear waves (above 20 kHz) were generated and observed in polyacrylamide samples. A cutoff frequency, from where the waves no longer propagate, was observed to vary depending on the mechanical properties of the samples. The ability of the Kelvin-Voigt (KV) model to explain the high cutoff frequency was investigated. Two alternative measurement techniques, Dynamic Mechanical Analysis (DMA) and Shear Wave Elastography (SWE), were used to complete the whole frequency range of the velocity dispersion curve while avoid capturing guided waves in the low frequency range (<3 kHz). The combination of the three measurement techniques provided rheology information from quasi-static to ultrasonic frequency range. A key observation was that the full frequency range of the dispersion curve was necessary if one wanted to infer accurate physical parameters from the rheological model. By comparing the low frequency range with the high frequency range, the relative errors for the viscosity parameter could reach 60 % and they could be higher with higher dispersive behavior. The high cutoff frequency may be predicted in materials that follow a KV model over their entire measurable frequency range. The mechanical characterization of cell culture media could benefit from the proposed OME technique.

8.
Adv Healthc Mater ; 11(19): e2200251, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35857383

RESUMEN

Osteoarthritis is a disease with a great socioeconomic impact and mainly affects articular cartilage, a tissue with reduced self-healing capacity. In this work, 3D printed 1,4 butanediol thermoplastic polyurethane (b-TPUe) scaffolds are functionalized and infrapatellar mesenchymal stem cells are used as the cellular source. Since b-TPUe is a biomaterial with mechanical properties similar to cartilage, but it does not provide the desired environment for cell adhesion, scaffolds are functionalized with two methods, one based on collagen type I and the other in 1-pyrenebutiric acid (PBA) as principal components. Alamar Blue and confocal assays display that PBA functionalized scaffolds support higher cell adhesion and proliferation for the first 21 days. However, collagen type I functionalization induces higher proliferation rates and similar cell viability than the PBA method. Further, both functionalization methods induce extracellular matrix synthesis, and the presence of chondrogenic markers (Sox9, Col2a, and Acan). Finally, SEM images probe that functionalized 3D printed scaffolds present much better cell/biomaterial interactions than controls and confirm early chondrogenesis. These results indicate that the two methods of functionalization in the highly hydrophobic b-TPUe enhance the cell-biomaterial interactions and the improvement in the chondro-inductive properties, which have great potential for application in cartilage tissue engineering.


Asunto(s)
Cartílago Articular , Ingeniería de Tejidos , Materiales Biocompatibles/farmacología , Butileno Glicoles , Diferenciación Celular , Condrogénesis , Colágeno Tipo I , Poliuretanos , Ingeniería de Tejidos/métodos , Andamios del Tejido/química
9.
Ultrason Sonochem ; 88: 106096, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35868210

RESUMEN

Sonocrystallization implies the application of ultrasound radiation to control the nucleation and crystal growth depending on the actuation time and intensity. Its application allows to induce nucleation at lower supersaturations than required under standard conditions. Although extended in inorganic and organic crystallization, it has been scarcely explored in protein crystallization. Now, that industrial protein crystallization is gaining momentum, the interest on new ways to control protein nucleation and crystal growth is advancing. In this work we present the development of a novel ultrasound bioreactor to study its influence on protein crystallization in agarose gel. Gel media minimize convention currents and sedimentation, favoring a more homogeneous and stable conditions to study the effect of an externally generated low energy ultrasonic irradiation on protein crystallization avoiding other undesired effects such as temperature increase, introduction of surfaces which induce nucleation, destructive cavitation phenomena, etc. In-depth statistical analysis of the results has shown that the impact of ultrasound in gel media on crystal size populations are statistically significant and reproducible.


Asunto(s)
Hidrogeles , Muramidasa , Ondas Ultrasónicas , Cristalización/métodos , Muramidasa/química , Proteínas/química
10.
Sensors (Basel) ; 22(12)2022 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-35746181

RESUMEN

Concrete-filled steel tubes (CFSTs) are structural elements that, as a consequence of an incorrect elaboration, can exhibit internal defects that cannot be visualized, being usually air voids. In this work, the detection of internal damage in CFST samples elaborated with a percentage of contained air voids in concrete, was carried out by performing a complete ultrasound scan using an immersion tank. The analysis of the ultrasound signals shows the differences presented in the amplitude of the fundamental frequency of the signal, and in the Broadband Ultrasound Attenuation (BUA), in comparison with a sample without defects. The main contribution of this study is the application of the BUA technique in CFST samples for the location of air voids. The results present a linear relationship between BUA averages over the window of the CFSTs and the percentage of air voids contained (Pearson's correlation coefficient r = 0.9873), the higher percentage of air voids, the higher values of BUA. The BUA algorithm could be applied effectively to distinguish areas with defects inside the CFSTs. Similar to the BUA results, the analysis in the frequency domain using the FFT and the STFT was sensitive in the detection of internal damage (Pearson's correlation coefficient r = -0.9799, and r = -0.9672, respectively). The results establish an improvement in the evaluation of CFST elements for the detection of internal defects.


Asunto(s)
Acero , Ultrasonido , Ultrasonografía/métodos
11.
Materials (Basel) ; 15(9)2022 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-35591704

RESUMEN

Thermoplastic resin fiber composites have an easy fabrication process, good mechanical properties, and compatible stiffness to tooth dentin. However, they have not yet attracted much interest in the field of dentistry. The current study was carried out to test a new proposed approach to manufacture a fiber reinforced composite endodontic post and evaluate its flexural strength through a two-point inclined loading test. The proposed fiber post manufacture approach depends upon a braiding technique of the glass fibers' (GF) reinforcing component with thermoplastic polypropylene (PP) resin fibers that will later represent the resin matrix after thermal melting. Posts were made of different core (70%) and sheath (30%) construction (PP/GF ratios) using three different GF types and seizing pre-treatment to both fiber types. Two-point inclined loading test at 45 °C applied force angle was used to test the posts' flexural strength. Fiber posts (1.6 mm in diameter) with pure GF (de-sized starch E-GF and pre-silanized S-GF) core, and sheath construction with higher PP/GF ratios, showed the significantly highest two-point bending strength (56.67 ± 4.89 and 53.96 ± 1.81 MPa, respectively), among experimental posts groups (except for the commercial control posts). However, posts with PP core type showed the lowest values (21.59 ± 1.86 and 16.54 ± 1.94 MPa for de-sized and E-glass sheath fibers, respectively). Based on these findings, the proposed approach was reliable in producing fiber-reinforced composite post with the desired dimensions and fiber distribution. Post construction with a pure GF core and higher PP/GF ratio showed considerably higher flexural strength and GF volume fraction comparable to commercial available post types.

12.
Sci Rep ; 12(1): 8354, 2022 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-35589817

RESUMEN

Corneal mechanical changes are believed to occur before any visible structural alterations observed during routine clinical evaluation. This study proposed developing an elastography technique based on torsional waves (TWE) adapted to the specificities of the cornea. By measuring the displacements in the propagation plane perpendicular to the axis of the emitter, the effect of guided waves in plate-like media was proven negligible. Ex vivo experiments were carried out on porcine corneal samples considering a group of control and one group of alkali burn treatment ([Formula: see text]OH) that modified the mechanical properties. Phase speed was recovered as a function of intraocular pressure (IOP), and a Kelvin-Voigt rheological model was fitted to the dispersion curves to estimate viscoelastic parameters. A comparison with uniaxial tensile testing with thin-walled assumptions was also performed. Both shear elasticity and viscosity correlated positively with IOP, being the elasticity lower and the viscosity higher for the treated group. The viscoelastic parameters ranged from 21.33 to 63.17 kPa, and from 2.82 to 5.30 Pa s, for shear elasticity and viscosity, respectively. As far as the authors know, no other investigations have studied this mechanical plane under low strain ratios, typical of dynamic elastography in corneal tissue. TWE reflected mechanical properties changes after treatment, showing a high potential for clinical diagnosis due to its rapid performance time and paving the way for future in vivo studies.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Animales , Córnea/diagnóstico por imagen , Elasticidad , Diagnóstico por Imagen de Elasticidad/métodos , Porcinos , Tonometría Ocular , Viscosidad
13.
Sci Rep ; 12(1): 7448, 2022 05 06.
Artículo en Inglés | MEDLINE | ID: mdl-35523858

RESUMEN

Fractional viscoelastic rheological models, such as the Kelvin Voigt Fractional Derivative model, have been proposed in the literature for modelling shear wave propagation in soft tissue. In this article, our previously developed wave propagation model for transluminal propagation based on a Kelvin Voigt Fractional Derivative wave equation is experimentally validated. The transluminal procedure uses the transmission and detection of shear waves through the luminal wall. The model was compared against high-speed camera observations in translucent elastography phantoms with similar viscoelastic properties to prostate tissue. An ad hoc cross-correlation procedure was used to reconstruct the angular displacement from the high-speed camera observations. Rheometry and shear wave elastography were used for characterising the shear wave velocity dispersion curve for the phantoms. Fractional viscoelastic properties were derived after fitting the dispersion curve to its analytical expression. Propagation features and amplitude spectra from simulations and high-speed camera observations were compared. The obtained results indicate that the model replicates the experimental observations with acceptable accuracy. The model presented here provides a useful tool to model transluminal procedures based on wave propagation and its interaction with the mechanical properties of the tissue outside the lumen.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Masculino , Fantasmas de Imagen , Reproducción , Reología , Viscosidad
14.
Materials (Basel) ; 14(9)2021 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-33946632

RESUMEN

Mechanical compatibility with the human dentin is a considerable issue when fabricating dental fiber posts. To this purpose, this study introduces a new method of fabricating compatible dental posts using braiding techniques of thermoplastic fibers (matrix) with glass fibers (reinforcement). Fifty fiber-reinforced composite (FRC) posts of thermoplastic yarns polypropylene (PP) braided with continuous filaments glass fibers (GFs) for reinforcement, varying in fiber volume fraction (FVF), and core types are fabricated and tested. Posts are performed using a braiding machine, and braids are placed in an aluminum mold. The filled mold is playced inside an oven at the melting temperature of the polypropylene to produce the final post's shape. An ultrasonic test is conducted to measure the shear modulus and Young's modulus of FRC post specimens by measuring the velocities of both the P-wave and S-wave. In order to ensure the accuracy of the measurements, each sample is measured three times, and then the means and standard deviations of each sample are calculated before analyzing the test results using the means of two steps, namely, clustering and comparing the P and R² values of each cluster, which revealed that FVF, fiber mass, and core type of the specimen had a significant effect on the resulted Young's and shear modulus. The results indicate that the proposed method can fabricate competitive dental posts with regard to different fabricating variables. The samples show Young's modulus ranges of from 10.08 GPa to 31.83 GPa. The following tested hypothesis is supported: the braiding technique of thermoplastic fibers with glass fibers will improve the mechanical compatibility of the resulting posts (ex vivo).

15.
Sensors (Basel) ; 21(8)2021 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-33920801

RESUMEN

In this article, a wave propagation model is presented as the first step in the development of a new type of transluminal procedure for performing elastography. Elastography is a medical imaging modality for mapping the elastic properties of soft tissue. The wave propagation model is based on a Kelvin Voigt Fractional Derivative (KVFD) viscoelastic wave equation, and is numerically solved using a Finite Difference Time Domain (FDTD) method. Fractional rheological models, such as the KVFD, are particularly well suited to model the viscoelastic response of soft tissue in elastography. The transluminal procedure is based on the transmission and detection of shear waves through the luminal wall. Shear waves travelling through the tissue are perturbed after encountering areas of altered elasticity. These perturbations carry information of medical interest that can be extracted by solving the inverse problem. Scattering from prostate tumours is used as an example application to test the model. In silico results demonstrate that shear waves are satisfactorily transmitted through the luminal wall and that echoes, coming from reflected energy at the edges of an area of altered elasticity, which are feasibly detectable by using the transluminal approach. The model here presented provides a useful tool to establish the feasibility of transluminal procedures based on wave propagation and its interaction with the mechanical properties of the tissue outside the lumen.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Simulación por Computador , Elasticidad , Masculino , Fantasmas de Imagen , Reología , Viscosidad
16.
Diagnostics (Basel) ; 11(4)2021 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-33918357

RESUMEN

Experimental evidence on testing a non-ultrasonic-based probe for a new approach in transluminal elastography was presented. The proposed modality generated shear waves by inducing oscillatory rotation on the lumen wall. Detection of the propagated waves was achieved at a set of receivers in mechanical contact with the lumen wall. The excitation element of the probe was an electromagnetic rotational actuator whilst the sensing element was comprised by a uniform anglewise arrangement of four piezoelectric receivers. The prototype was tested in two soft-tissue-mimicking phantoms that contained lumenlike conduits and stiffer inclusions. The shear wave speed of the different components of the phantoms was characterized using shear wave elastography. These values were used to estimate the time-of-flight of the expected reflections. Ultrafast ultrasound imaging, based on Loupas' algorithm, was used to estimate the displacement field in transversal planes to the lumenlike conduit and to compare against the readouts from the transluminal transmission-reception tests. Experimental observations between ultrafast imaging and the transluminal probe were in good agreement, and reflections due to the stiffer inclusions were detected by the transluminal probe. The obtained experimental evidence provided proof-of-concept for the transluminal elastography probe and encouraged further exploration of clinical applications.

17.
Front Physiol ; 12: 749372, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35140623

RESUMEN

The Finite Element Method (FEM) models are valuable tools to create an idea of the behavior of any structure. The complexity of the joints, materials, attachment areas, and boundary conditions is an open issue in biomechanics that needs to be addressed. Scapholunate instability is the leading cause of wrist pain and disability among patients of all ages. It is needed a better understanding of pathomechanics to develop new effective treatments. Previous models have emulated joints like the ankle or the knee but there are few about the wrist joint. The elaboration of realistic computational models of the carpus can give critical information to biomedical research and surgery to develop new surgical reconstructions. Hence, a 3D model of the proximal carpal row has been created through DICOM images, making a reduced wrist model. The materials, contacts, and ligaments definition were made via open-source software to extract results and carry on a reference comparison. Thus, considering the limitations that a reduced model could carry on (unbalanced forces and torques), the stresses that result in the scapholunate interosseous ligament (SLIL) lead us to a bones relative displacement, which support the kinematics hypothesis in the literature as the distal carpal row moves as a rigid solid with the capitate bone. Also, experimental testing is performed, successfully validating the linear strength values of the scapholunate ligament from the literature.

18.
Diagnostics (Basel) ; 10(11)2020 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-33218002

RESUMEN

Transient or acoustic radiation force elastography (ARFE) is becoming the most extended technology to assess cervical effacement, additionally to the Bishop test and conventional ultrasound. However, a debate on the fetal safety has been opened due to the high intensity focused beam emitted to produce shear waves. This work is aimed at providing preliminary data to assess clinical effects of fetal exposure. A follow-up study in newborns of 42 women exposed to ARFE during pregnancy was carried out to explore neonatal hypoacusia, Apgar test, and anthropometry. No hypoacusia cases attributable to ARFE were observed. The Apgar test at five minutes scored normally in all the newborns. Comparisons between anthropometric measurements showed no significant statistically differences. The results preclude to state the harmfulness nor the safety of ARFE. However, given the concern on the high level of energy and the potential risk of harmful bioeffects, larger studies are recommended.

19.
Sensors (Basel) ; 20(16)2020 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-32764345

RESUMEN

This paper presents the results of the comparison between a proposed Fourth Order Elastic Constants (FOECs) nonlinear model defined in the sense of Landau's theory, and the two most contrasted hyperelastic models in the literature, Mooney-Rivlin, and Ogden models. A mechanical testing protocol is developed to investigate the large-strain response of ex vivo cervical tissue samples in uniaxial tension in its two principal anatomical locations, the epithelial and connective layers. The final aim of this work is to compare the reconstructed shear modulus of the epithelial and connective layers of cervical tissue. According to the obtained results, the nonlinear parameter A from the proposed FOEC model could be an important biomarker in cervical tissue diagnosis. In addition, the calculated shear modulus depended on the anatomical location of the cervical tissue (µepithelial = 1.29 ± 0.15 MPa, and µconnective = 3.60 ± 0.63 MPa).


Asunto(s)
Dinámicas no Lineales , Enfermedades del Cuello del Útero , Elasticidad , Femenino , Humanos , Estrés Mecánico , Enfermedades del Cuello del Útero/diagnóstico
20.
Sensors (Basel) ; 20(8)2020 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-32331295

RESUMEN

The adoption of multiscale approaches by the biomechanical community has caused a major improvement in quality in the mechanical characterization of soft tissues. The recent developments in elastography techniques are enabling in vivo and non-invasive quantification of tissues' mechanical properties. Elastic changes in a tissue are associated with a broad spectrum of pathologies, which stems from the tissue microstructure, histology and biochemistry. This knowledge is combined with research evidence to provide a powerful diagnostic range of highly prevalent pathologies, from birth and labor disorders (prematurity, induction failures, etc.), to solid tumors (e.g., prostate, cervix, breast, melanoma) and liver fibrosis, just to name a few. This review aims to elucidate the potential of viscous and nonlinear elastic parameters as conceivable diagnostic mechanical biomarkers. First, by providing an insight into the classic role of soft tissue microstructure in linear elasticity; secondly, by understanding how viscosity and nonlinearity could enhance the current diagnosis in elastography; and finally, by compounding preliminary investigations of those elastography parameters within different technologies. In conclusion, evidence of the diagnostic capability of elastic parameters beyond linear stiffness is gaining momentum as a result of the technological and imaging developments in the field of biomechanics.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Viscosidad , Fenómenos Biomecánicos , Humanos