1.
Imaging Sci Dent ; 54(2): 139-145, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38948185

RESUMEN

Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test. Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41). Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39072795

RESUMEN

OBJECTIVES: To evaluate the influence of multiplanar reconstruction thickness on the detection of peri-implant bone defects with a standalone zirconia implant and compare it to when another implant is in the vicinity using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: Five dry human mandibles were used to create twenty implant sites in the second premolar and first molar regions. The OP300 Maxio was used to acquire CBCT images (90 kVp, 6.3 mA, 5 × 5 cm FOV, and 0.125 mm3 voxel size) before and after creating 3 mm peri-implant bone defects in the buccal aspect of the premolar region. Half of the scans featured a single zirconia implant in the premolar region, while the others had two implants in the premolar and molar regions. Three reconstruction thicknesses (0.125 mm, 1 mm, and 2 mm) were considered for the multiplanar reconstruction analyses. Five oral and maxillofacial radiologists assessed the detection of peri-implant bone defects using a 5-point scale. Diagnostic parameters were calculated and compared using Two-way ANOVA (α = .05). RESULTS: The studied factors showed no significant influence on the diagnosis of peri-implant bone defects (p > .05). Diagnostic performance was notably higher with a single implant, especially with a 2-mm reconstruction thickness (AUC = 0.88, sensitivity = 0.68, specificity = 0.94). Although the differences were not statistically significant, the results were more modest when two implants were present (AUC = 0.80, sensitivity = 0.58, specificity = 0.82). CONCLUSIONS: The presence of an adjacent zirconia implant and variations in reconstruction thickness did not influence the detection of 3 mm buccal peri-implant bone defects on CBCT images.

3.
Artículo en Inglés | MEDLINE | ID: mdl-37940483

RESUMEN

OBJECTIVE: We evaluated the influence of an adjacent zirconium implant, tube current (mA), and a metal artifact reduction algorithm (MARA) on horizontal root fracture (HRF) diagnosis in cone beam computed tomography (CBCT). STUDY DESIGN: Nineteen teeth (9 with HRF, 10 without) were individually placed in a human maxilla. Scan volumes were acquired without and with a zirconium implant adjacent to the tooth at settings of 4, 8, and 10 mA, with MARA disabled and enabled, using a 5×5 cm field of view, 0.085-mm voxel size, and 90 kV. Four maxillofacial radiologists individually assessed the scans. Diagnostic metrics were compared by multiway analysis of variance (α=5%). Inter- and intraexaminer agreements for HRF diagnosis were evaluated with the weighted kappa test. RESULTS: Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were significantly lower in the presence of the implant (P≤.005). AUC values were higher in scans obtained with 8 and 10 mA compared with 4 mA (P=0.010), but 10 mA without MARA was better with the implant present. MARA did not significantly influence outcomes (P≥0.240). Inter- and intraexaminer agreements ranged from moderate to almost perfect. CONCLUSIONS: The presence of the zirconium implant impairs HRF detection. Settings of 8 or 10 mA improve HRF detection regardless MARA condition without the implant. With an adjacent implant, 10 mA without MARA is recommended to improve diagnostic performance.


Asunto(s)
Fracturas de los Dientes , Raíz del Diente , Humanos , Raíz del Diente/diagnóstico por imagen , Circonio , Fracturas de los Dientes/diagnóstico por imagen , Artefactos , Tomografía Computarizada de Haz Cónico/métodos , Algoritmos
4.
Artículo en Inglés | MEDLINE | ID: mdl-37468380

RESUMEN

OBJECTIVE: This study evaluated changes in image quality and the presence and size of artifacts on radiographs obtained with photostimulable phosphor (PSP) plates after disinfection with 70% ethyl alcohol and 70% isopropyl alcohol. STUDY DESIGN: Eight PSP receptors (4 Express and 4 VistaScan) were used for the investigation. Two Express and 2 VistaScan receptors were disinfected with 70% ethyl alcohol, and 2 Express and 2 VistaScan receptors were disinfected with 70% isopropyl alcohol. Before disinfection and after every 5 disinfections, 2 radiographs of an aluminum stepwedge and 2 radiographs of an acrylic block were acquired using each receptor. The gray values of the radiographs were analyzed regarding contrast, density, uniformity, and noise. Four oral radiologists evaluated the images for the presence of artifacts, and 2 measured the artifacts. RESULTS: Differences in image contrast were significantly larger with isopropyl alcohol (P < .0001). Artifact size was significantly greater with the VistaScan system when isopropyl alcohol was used as the disinfectant (P < .0001). The correlation between the number of disinfections and artifact size was moderately positive with the Express system (P < .05) and strongly positive with the VistaScan system (P < .05) with both disinfectants. CONCLUSIONS: Small artifacts restricted to the edges of the image were observed with disinfection using both types of alcohol, and a positive correlation was found between artifact size and the number of disinfections. However, artifacts appeared earlier and of greater size with the VistaScan system when disinfected with 70% isopropyl alcohol. Thus, we recommend using 70% ethyl alcohol to disinfect PSP receptors, with attention placed on its action and evaporation times.


Asunto(s)
2-Propanol , Radiografía Dental Digital , Humanos , Radiografía Dental Digital/métodos , Desinfección/métodos , Artefactos , Intensificación de Imagen Radiográfica/métodos , Etanol
5.
Braz Dent J ; 34(1): 39-44, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36888843

RESUMEN

The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Asunto(s)
Radiografía Dental Digital , Radiografía Dental Digital/métodos , Reproducibilidad de los Resultados
6.
Braz. dent. j ; 34(1): 39-44, Jan.-Feb. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1420574

RESUMEN

Abstract The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Resumo Objetivou-se avaliar a influência do uso excessivo de uma placa de fósforo fotoestimulável (PSP) na densidade, ruído e contraste das radiografias. Foram adquiridas radiografias de um bloco de acrílico com uma PSP do sistema intraoral Express para avaliar a densidade e o ruído da imagem. Inicialmente, cinco imagens foram obtidas e exportadas (primeiro grupo). Após 400 exposições aos raios X e escaneamentos, outras cinco imagens foram obtidas e exportadas (segundo grupo). O mesmo procedimento foi feito após 800 (terceiro grupo), 1200 (quarto grupo), 1600 (quinto grupo) e 2000 aquisições (sexto grupo), resultando em 30 imagens a serem avaliadas. A média e o desvio padrão dos valores de cinza foram calculados para as imagens usando o software ImageJ. Para análise de contraste, foram adquiridas radiografias de uma escala de alumínio com uma nova PSP seguindo os mesmos intervalos de aquisição. A porcentagem de variação do contraste foi calculada. Outras duas PSP sem uso prévio foram utilizadas para avaliar a reprodutibilidade dos métodos. A comparação dos resultados entre os grupos de aquisição foi realizada pela Análise de Variância one-way (α=0,05). O Coeficiente de Correlação Intraclasse (ICC) avaliou a reprodutibilidade dos receptores. O ruído da imagem não diferiu entre os grupos (p>0,05). Houve um leve aumento na densidade após 400 aquisições e uma pequena diferença no contraste para todos os grupos de aquisição sem padrão de aumento ou diminuição (p<0,05). O ICC mostrou excelente confiabilidade para os métodos. Portanto, o uso excessivo da PSP afetou levemente a densidade e o contraste radiográfico.

7.
Artículo en Inglés | MEDLINE | ID: mdl-36566136

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the influence of the extensive use of a photostimulable phosphor (PSP) receptor on the diagnosis of proximal carious lesions. STUDY DESIGN: Forty posterior teeth were paired and mounted in 20 phantoms. Using a PSP receptor of the Express intraoral system, 1 radiograph of each phantom was acquired, totaling 20 radiographs (group 1). After 400 acquisitions, another radiograph of each phantom was obtained, totaling 20 new radiographs (group 2). This procedure was also done after 800 (group 3), 1,200 (group 4), and 1,600 (group 5) acquisitions, resulting in 100 radiographs. Another 40 radiographs (20 phantoms × 2 groups) were obtained with a second PSP sensor to evaluate the diagnostic replicability of the receptors. All 140 radiographs were assessed independently by 5 examiners for the presence of proximal caries. Area under the receiver operating characteristic curve, sensitivity, and specificity were calculated and compared among the groups by analysis of variance. The Student t test evaluated the diagnostic replicability of the receptors. The significance level was set at 5% (P < .05). RESULTS: The diagnostic outcomes for proximal caries did not differ among the groups (P ≥ .37). The diagnostic values did not differ among the radiographs acquired with the 2 PSP receptors (P ≥ .75). CONCLUSIONS: The diagnosis of proximal carious lesions was not affected by extensive use of the PSP receptor.


Asunto(s)
Caries Dental , Radiografía de Mordida Lateral , Humanos , Caries Dental/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Diente Molar/patología , Sensibilidad y Especificidad
8.
Clin Oral Investig ; 26(7): 4743-4752, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35267096

RESUMEN

OBJECTIVES: To evaluate the influence of digital filters of intraoral radiographic systems on the diagnosis of simulated internal and external root resorptions and image quality. MATERIALS AND METHODS: Internal root resorption (IRR) and external root resorption (ERR) were simulated in 34 teeth. For image acquisition, two radiographic systems were used: Digora Toto and VistaScan. All filters available in these systems were applied. Three observers scored the detection of root resorptions in a 5-point scale. The noise and the contrast-to-noise ratio (CNR) were calculated. The area under ROC curve, sensitivity, specificity, and accuracy were obtained. One-way ANOVA with Tukey's post hoc tests compared the diagnostic values, noise, and CNR between the filters (α = 0.05). RESULTS: For ERR, there were no significant differences in diagnostic values between the filters tested for both systems. For IRR, Original and Noise Reduction filters presented higher sensitivity than the Sharpen2 filter for images from Digora Toto, with no differences between the other groups. For VistaScan, there were no significant differences of diagnostic values between the groups studied. Noise values differed among the filters of both systems. The CNR of the filters differed only for the bone region for Digora Toto, while for VistaScan, both tooth and bone regions differed. CONCLUSIONS: Despite promoting changes in pixel intensities and affecting the noise level of the radiographic images, the digital filters of Digora Toto and VistaScan systems do not affect the diagnosis of internal or external root resorptions. CLINICAL RELEVANCE: Digital filters are common tools in digital radiographic systems and may be used by the professional without impairment in root resorptions diagnosis.