Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Rofo ; 185(3): 219-27, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23196834

RESUMEN

PURPOSE: To evaluate morphologic characteristics and establish a standardized diagnostic algorithm to differentiate benign cystic pancreatic tumors (CPTs) in non-pancreatitis patients using multidetector computed tomography (CT) and magnetic resonance imaging (MRI). MATERIALS AND METHODS: Patients with histopathologically proven CPTs who had undergone MRI and/or CT and subsequent tumor resection in our institution were retrospectively identified. Images were analyzed for morphology and enhancement patterns by three independent blinded observers. Preoperative image findings were correlated with histopathological results. Based on the evaluated morphologic parameters, a standardized diagnostic algorithm was designed to help characterize the lesions. RESULTS: A total of 62 consecutive patients with 64 CPTs were identified from the surgical database (21 intraductal papillary mucinous neoplasms; 10 mucinous cystic neoplasms; 12 serous microcystic adenomas; 3 serous oligocystic adenomas; 6 solid pseudopapillary tumors; 12 neuroendocrine neoplasms). The overall averaged accuracy for the 3 observers was 89.9 % for CT and 93.1 % for MRI with increasing overall accuracy in relation to the experience of the observer (88.2 %, 91.5 %, and 93.8 %, respectively). Overall, the generalized kappa value was 0.69 (CT, 0.64; MRI, 0.76); p < 0.001). The accuracy of the standardized diagnostic algorithm was 91.1 %. CONCLUSION: It is possible to characterize benign CPTs with MRI and CT, while MRI appears to be superior to CT. Diagnostic accuracy depends on the observer's experience. The standardized algorithm can aid in the differential diagnosis but still needs to be tested in other patient populations.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada Multidetector/métodos , Quiste Pancreático/patología , Neoplasias Pancreáticas/patología , Adulto , Anciano , Algoritmos , Medios de Contraste/administración & dosificación , Diagnóstico Diferencial , Femenino , Humanos , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/normas , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/normas , Páncreas/patología , Sensibilidad y Especificidad
2.
Eur J Radiol ; 78(2): 302-6, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-20889275

RESUMEN

OBJECTIVE: To assess the possible extent of dose reduction for low-dose computed tomography (CT) in the detection of body-packing (ingested drug packets) as an alternative to plain radiographs in an animal model. MATERIALS AND METHODS: Twelve packets containing cocaine (purity >80%) were introduced into the intestine of an experimental animal (crossbred pig), which was then repeatedly examined by abdominal CT with stepwise dose reduction (tube voltage, 80 kV; tube current, 10-350 mA). Three blinded readers independently evaluated the CT datasets starting with the lowest tube current and noted the numbers of packets detected at the different tube currents used. In addition, 1 experienced reader determined the number of packets detectable on plain abdominal radiographs and ultrasound. RESULTS: The threshold for correct identification of all 12 drug packets was 100 mA for reader 1 and 125 mA for readers 2 and 3. Above these thresholds all 3 readers consistently identified all 12 packets. The effective dose of a low-dose CT scan with 125 mA (including scout view) was 1.0 mSv, which was below that of 2 conventional abdominal radiographs (1.2 mSv). The reader interpreting the conventional radiographs identified a total of 9 drug packets and detected 8 packets by abdominal ultrasound. CONCLUSIONS: Extensive dose reduction makes low-dose CT a valuable alternative imaging modality for the examination of suspected body-packers and might replace conventional abdominal radiographs as the first-line imaging modality.


Asunto(s)
Cocaína , Cuerpos Extraños/diagnóstico por imagen , Tracto Gastrointestinal/diagnóstico por imagen , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Cadáver , Dosis de Radiación , Porcinos , Ultrasonografía
3.
Rofo ; 182(12): 1082-90, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21104596

RESUMEN

PURPOSE: To compare lesion volume determination by applying diameter measurement and three different segmentation algorithms at different slice thicknesses reconstructed from computed tomography (CT) of a phantom model for hepatic colorectal metastases. MATERIALS AND METHODS: Based on CT attenuation measurements obtained retrospectively from 20 patients with colorectal liver metastases, a phantom model was designed with a sponge soaked with a dilution of contrast agent and 6 embedded polyamide spheres (diameter, 8 - 30 mm) to simulate the contrast behavior of liver metastases. CT scans were obtained and reconstructed at different slice thicknesses (0.625/1.25/2.5/3.75 mm; increment, 1). One observer performed software-aided volume determination using the maximum diameter, manual segmentation, seed point method, and threshold method six times for each lesion in a randomized order. Statistical analysis revealed the absolute and relative differences from the actual lesion volumes and the intraobserver differences as well as the influence of slice thickness for each method. RESULTS: The mean relative differences of the seed point method (1.2 - 5.9%) and manual segmentation (2.6 - 4.9%) were significantly lower than the threshold method (5.4 - 12.8%) and diameter measurement (12.3 - 18.5%; p < 0.01). Volume determination by manual segmentation and the seed point method benefited from the use of thin-slice CT datasets. The intraobserver variation was lowest when using the manual segmentation (1.5 - 3.3%) and the seed point method (2.2 - 3.9%; p < 0.001). CONCLUSION: Manual segmentation and the seed point method for thin CT slices were the methods with the lowest volume differences and intraobserver variation.


Asunto(s)
Neoplasias Colorrectales/diagnóstico por imagen , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Fantasmas de Imagen , Tomografía Computarizada Espiral/métodos , Carga Tumoral/fisiología , Humanos , Hígado/diagnóstico por imagen , Variaciones Dependientes del Observador , Sensibilidad y Especificidad , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA