Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Intervalo de año de publicación
1.
Acta Ortop Bras ; 27(3): 169-172, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31452615

RESUMEN

Superior labral tear from anterior to posterior (SLAP) is the most common disease in overhead sports practice. OBJECTIVE: to evaluate the functional outcome after tenodesis of long head biceps tendon (LHBT) in high-performance patients with isolated SLAP lesion refractory to conservative treatment. METHODS: Patients underwent the same open repair procedure, using an interference screw. RESULTS: Both patients presented good clinical results and returned to the sport with performance similar to that prior to the injury. CONCLUSION: The results favor the surgical treatment of these athletes with SLAP IV. Level of Evidence IV, Série de Casos.


A lesão labral superior anteroposterior (SLAP) é a doença mais comum em atletas em suspensão do solo. OBJETIVO: avaliar o resultado funcional após tenodese do TCLB (tendão do cabo longo do bíceps) nos pacientes atletas em suspensão de alta performance com lesão SLAP isolada refratária ao tratamento conservador. MÉTODOS: Os pacientes foram submetidos ao mesmo procedimento de reparo por via aberta, com uso de parafuso de interferência. RESULTADOS: Ambos os pacientes apresentaram bons resultados clínicos e retornaram ao esporte com performance semelhante ao prévio à lesão. CONCLUSÃO: Os resultados favorecem o tratamento cirúrgico desses atletas com SLAP IV. Nível de evidencia IV, Series of Cases.

2.
Rev. bras. ortop ; 43(11/12): 465-473, nov.-dez. 2008. ilus, tab
Artículo en Portugués | LILACS | ID: lil-506716

RESUMEN

OBJETIVO: Desenvolver uma porca para fixação óssea (PFO) com o objetivo de aumentar a estabilidade da osteossíntese interna. MÉTODOS: Foram utilizados 16 cadáveres frescos (32 extremidades proximais do úmero), sendo oito masculinos e oito femininos, com média de idade de 60,56 anos. Em cada um dos 16 cadáveres, o úmero de um dos braços foi fixado com sistema de placa-parafuso-PFO e o contralateral, com o sistema placa-parafuso-porca de metal convencional. Foi aplicada uma força sobre os sistemas, medida por meio de torquímetro, até que um dos elementos falhasse (porca de polietileno, porca convencional ou osso). Depois, foi medida a força usada individualmente por 20 ortopedistas para apertar parafusos até que acreditassem que o sistema podia ser considerado como estável. Todos os resultados foram anotados e avaliados estatisticamente. RESULTADOS: Na avaliação da força média utilizada para aperto de parafusos, nas fixações rotineiras, individualmente, por 20 ortopedistas experientes, registrou-se a força média de 3,18N.m, força esta inferior à resistência do sistema placa-parafuso-PFO, que foi de 6,37N.m. A falha do sistema no osso com a PFO ocorreu em três casos e do sistema no osso com a porca de metal, em 10. CONCLUSÃO: A porca PFO mostrou-se menos agressiva ao osso que a porca metálica convencional, apresentando menor índice de fratura no osso. A força média aplicada pelo ortopedista não é capaz de quebrar a porca e levar a falha do sistema.


OBJECTIVE: To develop a bone fixation nut (PFO) for the purpose of increasing the internal osteosynthesis stability. METHODS: 16 fresh cadavers were used (32 proximal humeral extremities), eight male and eight female, mean age of 60.56 years. In each of the 16 cadavers, the humerus of one of the arms was fixated with a PFO-plate-screw system, and the contralateral was fixated with the plate-screw-nut system made of conventional metal. A load was applied on the system and measured by a torquemeter till one of the elements failed (polyethylene nut, conventional nut, or bone). The load individually used by 20 orthopedists to tighten the screws till the point they believed that the system was stable was measured. All of the results were noted down and statistically evaluated. RESULTS: In the evaluation of the mean load used to tighten the screws, in routine fixations, individually, by 20 experienced orthopedists, a mean load of 3.18 N.m was found, this load being lower than the strength of the PFO-plate-screw system, that was 6.37 N.m. Failure of the system in the bone with the PFO occurred in three cases and failure of the system with the metal nut occurred in 10 cases. CONCLUSION: The PFO nut showed to be less aggressive to the bone than the conventional metal nut, and presented a lower incidence of bone fracture. The mean load applied by the orthopedist is not sufficient to break the nut and lead to a system failure.


Asunto(s)
Cadáver , Dispositivos de Fijación Ortopédica , Osteoporosis , Fracturas del Hombro/cirugía
3.
Rev. bras. ortop ; 36(8): 301-6, ago. 2001. ilus, tab
Artículo en Portugués | LILACS | ID: lil-296231

RESUMEN

Entre março de 1990 e maio de 1999, 13 pacientes, totalizando 13 ombros, foram submetidos à artrodese de ombro com placa de compressäo dinâmica estreita moldada e enxerto ósseo esponjoso. A seqüela de lesäo do plexo braquial foi a causa mais freqüente de indicaçäo para a artrodese (quatro pacientes). Nove homens e quatro mulheres, com idade média de 41 anos e quatro meses, tiveram seguimento médio de 53 meses. Todos os pacientes com dor no pré-operatório tiveram alívio dos sintomas e a consolidaçäo ocorreu em todos os casos, em média aos quatro meses e 10 dias após a cirurgia. Sete pacientes conseguiam levar a mäo à cabeça e seis faziam higiene da axila oposta. Houve cinco complicaçöes em quatro pacientes, sem maiores conseqüências clínicas. A artrodese de ombro com placa de compressäo dinâmica é procedimento complexo, porém, quando indicada, dá excelentes resultados em relaçäo à consolidaçäo e satisfaçäo dos pacientes.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Artrodesis , Hombro/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA