Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 58(11)2022 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-36363567

RESUMEN

Background and Objectives: Fractures of the proximal femur are a life-changing and life-threatening event for older people. Concomitant malnutrition has been described as an independent risk factor for complications and mortality. Therefore, we examined the influence of albumin and body mass index (BMI) as parameters for the nutritional state on the outcome after geriatric hip fracture surgery. Materials and Methods: Data were retrospectively collected from hospital information systems, and complications and all other parameters were obtained from patient charts. We included patients aged 70 years or above with a fracture of the proximal femur. We excluded periprosthetic and peri-implant fractures and patients with a missing BMI or albumin value. Results: Patients with a BMI below 20 kg/m2 were more likely to be female but did not differ from the normal BMI group in terms of baseline parameters. Patients with hypoalbuminemia had a higher ASA grade and Charlson Comorbidity Index, as well as a lower hemoglobin value and prothrombin time compared to those with normal albumin values and low BMI. Hypoalbuminemia was associated with significantly increased rates of complications (57.9% vs. 46.7%, p = 0.04) and mortality (10.3% vs. 4.1%, p = 0.02). Blood loss and transfusion rates were higher in the hypoalbuminemia group. Patients with a BMI below 20 kg/m2 had a higher risk of intraoperative cardiac arrest (2.6% vs. 0.4%, p = 0.05) but did not show higher mortality rates than patients with a BMI above 20 kg/m2. However, the outcome parameter could not be confirmed in the regression analysis. Conclusions: Hypoalbuminemia might be an indicator for more vulnerable patients with a compromised hemoglobin value, prothrombin time, and ASA grade. Therefore, it is also associated with higher mortality and postoperative complications. However, hypoalbuminemia was not an independent predictor for mortality or postoperative complications, but low albumin values were associated with a higher CCI and ASA grade than in patients with a BMI below 20 kg/m2.


Asunto(s)
Fracturas de Cadera , Hipoalbuminemia , Desnutrición , Humanos , Anciano , Femenino , Masculino , Índice de Masa Corporal , Estudios Retrospectivos , Hipoalbuminemia/complicaciones , Desnutrición/complicaciones , Fracturas de Cadera/complicaciones , Fracturas de Cadera/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Fémur , Albúminas
2.
J Arthroplasty ; 33(8): 2671-2676, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29699828

RESUMEN

BACKGROUND: Wear debris is a major factor in aseptic loosening of total hip arthroplasty. Ultra high molecular weight polyethylene inlays are known for significant wear, and the following generation, highly cross-linked polyethylene (HCLPE), has shown promising in vitro and short-term in vivo results. This study aimed to investigate wear debris of HCLPE liners with ceramic heads after 9 years to reveal the in vivo wear kinetics of this common bearing combination. METHODS: Fifty-seven patients (72 hips; 46.5 ± 15.5 years; range 16-76 years) who underwent hip arthroplasty with an HCLPE liner (28- or 32-mm Biolox forte ceramic head) were followed up (mean 9.1 ± 2.4 years; range 3.9-13.8 years). Conventional anteroposterior X-rays were analyzed using Hip Analysis Suite software. RESULTS: Volumetric wear had a mean of 38.67 ± 22.09 mm3/year, 333.08 ± 183.93 mm3 overall, and linear wear was 0.063 ± 0.03 mm/year and 0.546 ± 0.27 mm overall. Male patients had a significantly higher wear rate (46.42 ± 27.68 mm3/year) and total wear (400.71 ± 235.21 mm3). Larger femoral heads had a significantly higher wear rate (43.10 ± 23.93 mm3/year) and total wear (364.23 ± 203.68 mm3). Regression analysis showed a significant cubic relationship (R2 = 0.307) with increasing yearly wear after approximately 108 months postoperatively. CONCLUSIONS: HCLPE liners show significant in vivo wear after 9 years. While the total wear compared to ultra high molecular weight polyethylene liners was decreased, the wear kinetics show a comparable course. The increase in wear rate after only 108 months postoperatively is especially alarming. Longer term follow-up is needed to distinguish the long-term superiority of HCLPE liners in polyethylene-ceramic paired hip arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Polietileno , Polietilenos , Falla de Prótesis , Adolescente , Adulto , Anciano , Cerámica , Femenino , Cabeza Femoral , Estudios de Seguimiento , Prótesis de Cadera , Humanos , Cinética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Radiografía , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA