Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Biomech ; 57: 8-17, 2017 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-28431748

RESUMEN

We present a novel biorobotic framework comprised of a biological muscle-tendon unit (MTU) mechanically coupled to a feedback controlled robotic environment simulation that mimics in vivo inertial/gravitational loading and mechanical assistance from a parallel elastic exoskeleton. Using this system, we applied select combinations of biological muscle activation (modulated with rate-coded direct neural stimulation) and parallel elastic assistance (applied via closed-loop mechanical environment simulation) hypothesized to mimic human behavior based on previously published modeling studies. These conditions resulted in constant system-level force-length dynamics (i.e., stiffness), reduced biological loads, increased muscle excursion, and constant muscle average positive power output-all consistent with laboratory experiments on intact humans during exoskeleton assisted hopping. Mechanical assistance led to reduced estimated metabolic cost and MTU apparent efficiency, but increased apparent efficiency for the MTU+Exo system as a whole. Findings from this study suggest that the increased natural resonant frequency of the artificially stiffened MTU+Exo system, along with invariant movement frequencies, may underlie observed limits on the benefits of exoskeleton assistance. Our novel approach demonstrates that it is possible to capture the salient features of human locomotion with exoskeleton assistance in an isolated muscle-tendon preparation, and introduces a powerful new tool for detailed, direct examination of how assistive devices affect muscle-level neuromechanics and energetics.


Asunto(s)
Locomoción/fisiología , Músculo Esquelético/fisiología , Robótica/instrumentación , Tendones/fisiología , Animales , Fenómenos Biomecánicos , Elasticidad , Gravitación , Ranidae
2.
Proc Natl Acad Sci U S A ; 112(43): E5891-8, 2015 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-26460038

RESUMEN

In terrestrial locomotion, there is a missing link between observed spring-like limb mechanics and the physiological systems driving their emergence. Previous modeling and experimental studies of bouncing gait (e.g., walking, running, hopping) identified muscle-tendon interactions that cycle large amounts of energy in series tendon as a source of elastic limb behavior. The neural, biomechanical, and environmental origins of these tuned mechanics, however, have remained elusive. To examine the dynamic interplay between these factors, we developed an experimental platform comprised of a feedback-controlled servo-motor coupled to a biological muscle-tendon. Our novel motor controller mimicked in vivo inertial/gravitational loading experienced by muscles during terrestrial locomotion, and rhythmic patterns of muscle activation were applied via stimulation of intact nerve. This approach was based on classical workloop studies, but avoided predetermined patterns of muscle strain and activation-constraints not imposed during real-world locomotion. Our unconstrained approach to position control allowed observation of emergent muscle-tendon mechanics resulting from dynamic interaction of neural control, active muscle, and system material/inertial properties. This study demonstrated that, despite the complex nonlinear nature of musculotendon systems, cyclic muscle contractions at the passive natural frequency of the underlying biomechanical system yielded maximal forces and fractions of mechanical work recovered from previously stored elastic energy in series-compliant tissues. By matching movement frequency to the natural frequency of the passive biomechanical system (i.e., resonance tuning), muscle-tendon interactions resulting in spring-like behavior emerged naturally, without closed-loop neural control. This conceptual framework may explain the basis for elastic limb behavior during terrestrial locomotion.


Asunto(s)
Locomoción , Músculos/fisiología , Tendones/fisiología , Animales , Elasticidad , Rana catesbeiana/fisiología
3.
J Exp Biol ; 218(Pt 19): 3150-9, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26232413

RESUMEN

A growing body of research on the mechanics and energetics of terrestrial locomotion has demonstrated that elastic elements acting in series with contracting muscle are critical components of sustained, stable and efficient gait. Far fewer studies have examined how the nervous system modulates muscle-tendon interaction dynamics to optimize 'tuning' or meet varying locomotor demands. To explore the fundamental neuromechanical rules that govern the interactions between series elastic elements (SEEs) and contractile elements (CEs) within a compliant muscle-tendon unit (MTU), we used a novel work loop approach that included implanted sonomicrometry crystals along muscle fascicles. This enabled us to decouple CE and SEE length trajectories when cyclic strain patterns were applied to an isolated plantaris MTU from the bullfrog (Lithobates catesbeianus). Using this approach, we demonstrate that the onset timing of muscle stimulation (i.e. stimulation phase) that involves a symmetrical MTU stretch-shorten cycle during active force production results in net zero mechanical power output, and maximal decoupling of CE and MTU length trajectories. We found it difficult to 'tune' the muscle-tendon system for strut-like isometric force production by adjusting stimulation phase only, as the zero power output condition involved significant positive and negative mechanical work by the CE. A simple neural mechanism - adjusting muscle stimulation phase - could shift an MTU from performing net zero to net positive (energy producing) or net negative (energy absorbing) mechanical work under conditions of changing locomotor demand. Finally, we show that modifications to the classical work loop paradigm better represent in vivo muscle-tendon function during locomotion.


Asunto(s)
Contracción Muscular/fisiología , Músculo Esquelético/fisiología , Rana catesbeiana/fisiología , Tendones/fisiología , Animales , Fenómenos Biomecánicos , Locomoción/fisiología
4.
Bioinspir Biomim ; 9(4): 046018, 2014 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-25417578

RESUMEN

Development of robotic exoskeletons to assist/enhance human locomotor performance involves lengthy prototyping, testing, and analysis. This process is further convoluted by variability in limb/body morphology and preferred gait patterns between individuals. In an attempt to expedite this process, and establish a physiological basis for actuator prescription, we developed a simple, predictive model of human neuromechanical adaptation to a passive elastic exoskeleton applied at the ankle joint during a functional task. We modeled the human triceps surae-Achilles tendon muscle tendon unit (MTU) as a single Hill-type muscle, or contractile element (CE), and series tendon, or series elastic element (SEE). This modeled system was placed under gravitational load and underwent cyclic stimulation at a regular frequency (i.e. hopping) with and without exoskeleton (Exo) assistance. We explored the effect that both Exo stiffness (kExo) and muscle activation (Astim) had on combined MTU and Exo (MTU + Exo), MTU, and CE/SEE mechanics and energetics. Model accuracy was verified via qualitative and quantitative comparisons between modeled and prior experimental outcomes. We demonstrated that reduced Astim can be traded for increased kExo to maintain consistent MTU + Exo mechanics (i.e. average positive power (P⁺mech) output) from an unassisted condition (i.e. kExo = 0 kN · m⁻¹). For these regions of parameter space, our model predicted a reduction in MTU force, SEE energy cycling, and metabolic rate (Pmet), as well as constant CE P⁺mech output compared to unassisted conditions. This agreed with previous experimental observations, demonstrating our model's predictive ability. Model predictions also provided insight into mechanisms of metabolic cost minimization, and/or enhanced mechanical performance, and we concluded that both of these outcomes cannot be achieved simultaneously, and that one must come at the detriment of the other in a spring-assisted compliant MTU.


Asunto(s)
Modelos Biológicos , Movimiento/fisiología , Contracción Muscular/fisiología , Músculo Esquelético/fisiología , Aparatos Ortopédicos , Robótica/instrumentación , Tendones/fisiología , Biomimética/instrumentación , Simulación por Computador , Diseño Asistido por Computadora , Módulo de Elasticidad/fisiología , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Sistemas Hombre-Máquina
5.
J Theor Biol ; 353: 121-32, 2014 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-24641822

RESUMEN

We present a simplified Hill-type model of the human triceps surae-Achilles tendon complex working on a gravitational-inertial load during cyclic contractions (i.e. vertical hopping). Our goal was to determine the role that neural control plays in governing muscle, or contractile element (CE), and tendon, or series elastic element (SEE), mechanics and energetics within a compliant muscle-tendon unit (MTU). We constructed a 2D parameter space consisting of many combinations of stimulation frequency and magnitude (i.e. neural control strategies). We compared the performance of each control strategy by evaluating peak force and average positive mechanical power output for the system (MTU) and its respective components (CE, SEE), force-length (F-L) and -velocity (F-V) operating point of the CE during active force production, average metabolic rate for the CE, and both MTU and CE apparent efficiency. Our results suggest that frequency of stimulation plays a primary role in governing whole-MTU mechanics. These include the phasing of both activation and peak force relative to minimum MTU length, average positive power, and apparent efficiency. Stimulation amplitude was primarily responsible for governing average metabolic rate and within MTU mechanics, including peak force generation and elastic energy storage and return in the SEE. Frequency and amplitude of stimulation both played integral roles in determining CE F-L operating point, with both higher frequency and amplitude generally corresponding to lower CE strains, reduced injury risk, and elimination of the need for passive force generation in the CE parallel elastic element (PEE).


Asunto(s)
Tobillo/fisiología , Elasticidad , Metabolismo Energético/fisiología , Modelos Biológicos , Actividad Motora/fisiología , Músculo Esquelético/fisiología , Fenómenos Fisiológicos del Sistema Nervioso , Tendones/fisiología , Metabolismo Basal , Fenómenos Biomecánicos , Humanos , Contracción Muscular/fisiología
6.
J Appl Physiol (1985) ; 115(5): 579-85, 2013 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-23788578

RESUMEN

Inspired by elastic energy storage and return in tendons of human leg muscle-tendon units (MTU), exoskeletons often place a spring in parallel with an MTU to assist the MTU. However, this might perturb the normally efficient MTU mechanics and actually increase active muscle mechanical work. This study tested the effects of elastic parallel assistance on MTU mechanics. Participants hopped with and without spring-loaded ankle exoskeletons that assisted plantar flexion. An inverse dynamics analysis, combined with in vivo ultrasound imaging of soleus fascicles and surface electromyography, was used to determine muscle-tendon mechanics and activations. Whole body net metabolic power was obtained from indirect calorimetry. When hopping with spring-loaded exoskeletons, soleus activation was reduced (30-70%) and so was the magnitude of soleus force (peak force reduced by 30%) and the average rate of soleus force generation (by 50%). Although forces were lower, average positive fascicle power remained unchanged, owing to increased fascicle excursion (+4-5 mm). Net metabolic power was reduced with exoskeleton assistance (19%). These findings highlighted that parallel assistance to a muscle with appreciable series elasticity may have some negative consequences, and that the metabolic cost associated with generating force may be more pronounced than the cost of doing work for these muscles.


Asunto(s)
Articulación del Tobillo/fisiología , Tobillo/fisiología , Músculo Esquelético/fisiología , Caminata/fisiología , Adulto , Electromiografía/métodos , Metabolismo Energético/fisiología , Humanos , Pierna/fisiopatología , Masculino , Tendones/fisiología
7.
Neurotoxicology ; 33(3): 500-11, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22387230

RESUMEN

The occurrence of status epilepticus (SE) is considered the main cause of brain lesions and morphological alterations, such as hippocampal neuron loss, that result in chronic epilepsy. Previous work demonstrated the convulsive and widespread neuropathological effects of soman, an organophosphorus compound that causes SE and severe recurrent seizures as a result of exposure. Seizures begin rapidly after exposure, can continue for hours, and contribute to prolonged physical incapacitation of the victim. This study attempts to identify anticonvulsive and neuroprotective drugs against soman exposure. Male Sprague-Dawley rats were exposed to 1.0 LD(50) soman. EEGraphical and neuropathological (Fluoro-Jade B staining) effects were analyzed at 72 h post-exposure to soman and subsequent treatments with diazepam (DZP) alone or in combination with histone deacetylase inhibitors, suberoylanilide hydroxamic acid (SAHA) or valproic acid (VPA). The extent of brain damage was dependent on the length of SE and not on the number of recurrent seizures. DZP treatment alone decreased SE time and damage in hippocampus, amygdala, thalamus and cortex, but not in piriform nuclei. The combination of DZP and VPA 100 mg/kg showed more anticonvulsive effects, decreased SE time, and afforded more neuroprotection in the hippocampus, mainly the ventral portion. The combination DZP and SAHA 25 mg/kg was more neuroprotective, but not more anticonvulsant than DZP alone. The DZP combination with VPA HDAC inhibitor proved to be a good treatment for SE and neuronal damage caused by soman exposure.


Asunto(s)
Anticonvulsivantes/farmacología , Encéfalo/efectos de los fármacos , Sustancias para la Guerra Química/toxicidad , Diazepam/farmacología , Inhibidores de Histona Desacetilasas/farmacología , Neuronas/efectos de los fármacos , Fármacos Neuroprotectores/farmacología , Convulsiones/prevención & control , Soman/toxicidad , Animales , Encéfalo/patología , Encéfalo/fisiopatología , Mapeo Encefálico/métodos , Ondas Encefálicas/efectos de los fármacos , Citoprotección , Quimioterapia Combinada , Electroencefalografía , Ácidos Hidroxámicos/farmacología , Masculino , Neuronas/patología , Ratas , Ratas Sprague-Dawley , Convulsiones/inducido químicamente , Convulsiones/patología , Convulsiones/fisiopatología , Factores de Tiempo , Ácido Valproico/farmacología , Vorinostat
8.
Artículo en Inglés | MEDLINE | ID: mdl-22254377

RESUMEN

Robotic assistance for rehabilitation and enhancement of human locomotion has become a major goal of biomedical engineers in recent years. While significant progress to this end has been made in the fields of neural interfacing and control systems, little has been done to examine the effects of mechanical assistance on the biomechanics of underlying muscle-tendon systems. Here, we model the effects of mechanical assistance via a passive spring acting in parallel with the triceps surae-Achilles tendon complex during cyclic hopping in humans. We examine system dynamics over a range of biological muscle activation and exoskeleton spring stiffness. We find that, in most cases, uniform cyclic mechanical power production of the coupled system is achieved. Furthermore, unassisted power production can be reproduced throughout parameter space by trading off decreases in muscle activation with increases in ankle exoskeleton spring stiffness. In addition, we show that as mechanical assistance increases the biological muscle-tendon unit becomes less 'tuned' resulting in higher mechanical power output from active components of muscle despite large reductions in required force output.


Asunto(s)
Tendón Calcáneo/fisiología , Articulación del Tobillo/fisiología , Locomoción/fisiología , Modelos Biológicos , Músculo Esquelético/fisiología , Aparatos Ortopédicos , Robótica/métodos , Simulación por Computador , Humanos , Contracción Muscular/fisiología , Terapia Asistida por Computador/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA