1.
Semin Dial ; 19(6): 551-6, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17150059

RESUMEN

Intra-access static pressure ratio (SPR) (intra-access pressure/mean arterial pressure) can be measured during angioplasty (PTA) to assess the functional importance of an arteriovenous graft (AVG) stenosis. We used SPR in 70 patients with AVGs who underwent 98 angioplasty procedures. SPR was measured during angioplasty by placing a catheter tip at mid-access. Inflow stenosis (IF) = stenosis proximal to the tip of the catheter. Outflow stenosis (OF) = stenosis distal to the tip of the catheter up to the superior vena cava-atrial junction. Post PTA, access flow (Qa) was assessed within 2 weeks. Complete data sets for both SPR and Qa were available in 83 procedures. Using a normal SPR ratio of 0.3-0.4 at mid-graft, three patterns of SPR were noted. In 63 of 83 (76%) cases SPR was elevated prior to PTA (0.71 +/- 0.13 SD). PTA reduced SPR toward normal range (0.44 +/- 0.12) in 53 cases (84%). In the remaining 10 (16%), SPR decreased to a low value (0.22 +/- 0.03) and normalized (0.40 +/- .0.11) only after PTA of a coexisting inflow stenosis. In 12 of 83 (14%) procedures, the initial SPR was low (0.18 +/- 0.04) and increased toward normal (0.3 +/- 0.08) following IF stenosis PTA in seven (58%) cases. For the remaining five (42%) cases SPR increased to a high value (0.70 +/- 0.21) and decreased toward normal range (0.33 +/- 0.07) only after OF stenosis angioplasty. In 8 of 83 (10%) procedures, initial SPR was normal (0.33 +/- 0.02). Angiography revealed coexisting IF and OF stenoses. SPR remained within the normal range after PTA of these lesions (0.33 +/- 0.02). Qa increased significantly in 74 of 83 (89%) procedures (before = 572 +/- 201, after = 1109 +/- 368 ml/min; p < 0.001). SPR measurements can assist in hemodynamic assessment of an AVG during angioplasty procedure.


Asunto(s)
Angioplastia de Balón , Derivación Arteriovenosa Quirúrgica/efectos adversos , Presión Sanguínea , Oclusión de Injerto Vascular/fisiopatología , Oclusión de Injerto Vascular/terapia , Monitoreo Intraoperatorio , Anciano , Análisis de Varianza , Angiografía de Substracción Digital , Femenino , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Humanos , Fallo Renal Crónico/fisiopatología , Fallo Renal Crónico/terapia , Masculino , Persona de Mediana Edad , Circulación Renal , Diálisis Renal , Proyectos de Investigación , Resultado del Tratamiento , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA