1.
J Radiat Res ; 54 Suppl 1: i82-90, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23824132

RESUMEN

We propose a patient-specific planning target volume (PTV) to deal with interfractional variations, and test its feasibility in a retrospective treatment-planning study. Instead of using one planning image only, multiple scans are taken on different days. The target and organs at risk (OARs) are delineated on each images. The proposed PTV is generated from a union of those target contours on the planning images, excluding voxels of the OARs, and is denoted the PTV 'GP-OAR' (global prostate-organs at risk). The study is performed using 'plan of the day' adaptive workflow, which selects a daily plan from a library of plans based on a similarity comparison between the daily scan and planning images. The daily plans optimized for GP-OAR volumes are compared with those optimized for PTVs generated from a single prostate contour (PTV SP). Four CT serials of prostate cancer patient datasets are included in the test, and in total 28 fractions are simulated. The results show that the daily chosen GP-OAR plans provide excellent target coverage, with V95 values of the prostate mostly > 95%. In addition, dose delivered to the OARs as calculated from applying daily chosen GP-OAR plans is slightly increased but comparable to that calculated from applying daily SP plans. In general, the PTV GP-OARs are able to cover possible target variations while keeping dose delivered to the OARs at a similar level to that of the PTV SPs.


Asunto(s)
Radioterapia de Iones Pesados/métodos , Neoplasias de la Próstata/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Carbono/uso terapéutico , Humanos , Iones , Masculino , Movimiento (Física) , Órganos en Riesgo , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
2.
Phys Med Biol ; 58(4): 1013-25, 2013 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-23363558

RESUMEN

We propose a plan adaptation method for fast treatment plan generation in scanned ion beam therapy. Analysis of optimized treatment plans with carbon ions indicates that the particle number modulation of consecutive rasterspots in depth shows little variation throughout target volumes with convex shape. Thus, we extract a depth-modulation curve (DMC) from existing reference plans and adapt it for creation of new plans in similar treatment situations. The proposed method is tested with seven CT serials of prostate patients and three digital phantom datasets generated with the MATLAB code. Plans are generated with a treatment planning software developed by GSI using single-field uniform dose optimization for all the CT datasets to serve as reference plans and 'gold standard'. The adapted plans are generated based on the DMC derived from the reference plans of the same patient (intra-patient), different patient (inter-patient) and phantoms (phantom-patient). They are compared with the reference plans and a re-positioning strategy. Generally, in 1 min on a standard PC, either a physical plan or a biological plan can be generated with the adaptive method provided that the new target contour is available. In all the cases, the V95 values of the adapted plans can achieve 97% for either physical or biological plans. V107 is always 0 indicating no overdosage, and target dose homogeneity is above 0.98 in all cases. The dose received by the organs at risk is comparable to the optimized plans. The plan adaptation method has the potential for on-line adaptation to deal with inter-fractional motion, as well as fast off-line treatment planning, with either the prescribed physical dose or the RBE-weighted dose.


Asunto(s)
Iones/uso terapéutico , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Carbono/química , Humanos , Masculino , Modelos Estadísticos , Fantasmas de Imagen , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Estudios Retrospectivos , Programas Informáticos , Tomografía Computarizada por Rayos X/métodos
3.
Radiat Oncol ; 7: 55, 2012 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-22462523

RESUMEN

BACKGROUND: Treatment of moving target volumes with scanned particle beams benefits from treatment planning that includes the time domain (4D). Part of 4D treatment planning is calculation of the expected result. These calculation codes should be verified against suitable measurements. We performed simulations and measurements to validate calculation of the film response in the presence of target motion. METHODS: All calculations were performed with GSI's treatment planning system TRiP. Interplay patterns between scanned particle beams and moving film detectors are very sensitive to slight deviations of the assumed motion parameters and therefore ideally suited to validate 4D calculations. In total, 14 film motion parameter combinations with lateral motion amplitudes of 8, 15, and 20 mm and 4 combinations for lateral motion including range changes were used. Experimental and calculated film responses were compared by relative difference, mean deviation in two regions-of-interest, as well as line profiles. RESULTS: Irradiations of stationary films resulted in a mean relative difference of -1.52% ± 2.06% of measured and calculated responses. In comparison to this reference result, measurements with translational film motion resulted in a mean difference of -0.92% ± 1.30%. In case of irradiations incorporating range changes with a stack of 5 films as detector the deviations increased to -6.4 ± 2.6% (-10.3 ± 9.0% if film in distal fall-off is included) in comparison to -3.6% ± 2.5% (-13.5% ± 19.9% including the distal film) for the stationary irradiation. Furthermore, the comparison of line profiles of 4D calculations and experimental data showed only slight deviations at the borders of the irradiated area. The comparisons of pure lateral motion were used to determine the number of motion states that are required for 4D calculations depending on the motion amplitude. 6 motion states per 10 mm motion amplitude are sufficient to calculate the film response in the presence of motion. CONCLUSIONS: By comparison to experimental data, the 4D extension of GSI's treatment planning system TRiP has been successfully validated for film response calculations in the presence of target motion within the accuracy limitation given by film-based dosimetry.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador/métodos , Dosimetría por Película , Humanos , Movimiento (Física) , Dosis de Radiación , Dosificación Radioterapéutica
4.
Radiat Oncol ; 5: 61, 2010 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-20591160

RESUMEN

BACKGROUND: Scanned ion beam therapy of intra-fractionally moving tumors requires motion mitigation. GSI proposed beam tracking and performed several experimental studies to analyse the dosimetric precision of the system for scanned carbon beams. METHODS: A beam tracking system has been developed and integrated in the scanned carbon ion beam therapy unit at GSI. The system adapts pencil beam positions and beam energy according to target motion. Motion compensation performance of the beam tracking system was assessed by measurements with radiographic films, a range telescope, a 3D array of 24 ionization chambers, and cell samples for biological dosimetry. Measurements were performed for stationary detectors and moving detectors using the beam tracking system. RESULTS: All detector systems showed comparable data for a moving setup when using beam tracking and the corresponding stationary setup. Within the target volume the mean relative differences of ionization chamber measurements were 0.3% (1.5% standard deviation, 3.7% maximum). Film responses demonstrated preserved lateral dose gradients. Measurements with the range telescope showed agreement of Bragg peak depth under motion induced range variations. Cell survival experiments showed a mean relative difference of -5% (-3%) between measurements and calculations within the target volume for beam tracking (stationary) measurements. CONCLUSIONS: The beam tracking system has been successfully integrated. Full functionality has been validated dosimetrically in experiments with several detector types including biological cell systems.


Asunto(s)
Radiometría/métodos , Animales , Células CHO , Carbono , Cricetinae , Cricetulus , Iones , Movimiento (Física) , Radiometría/instrumentación , Dosificación Radioterapéutica , Efectividad Biológica Relativa
5.
Phys Med Biol ; 55(12): 3499-513, 2010 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-20508325

RESUMEN

Fast radiological range adaptation of the ion beam is essential when target motion is mitigated by beam tracking using scanned ion beams for dose delivery. Electromagnetically controlled deflection of a well-focused ion beam on a small static wedge degrader positioned between two dipole magnets, inside the beam delivery system, has been considered as a fast range adaptation method. The principle of the range adaptation method was tested in experiments and Monte Carlo simulations for the therapy beam line at the GSI Helmholtz Centre for Heavy Ions Research. Based on the simulations, ion optical settings of beam deflection and realignment of the adapted beam were experimentally applied to the beam line, and additional tuning was manually performed. Different degrader shapes were employed for the energy adaptation. Measured and simulated beam profiles, i.e. lateral distribution and range in water at isocentre, were analysed and compared with the therapy beam values for beam scanning. Deflected beam positions of up to +/-28 mm on degrader were performed which resulted in a range adaptation of up to +/-15 mm water equivalence (WE). The maximum deviation between the measured adapted range from the nominal range adaptation was below 0.4 mm WE. In experiments, the width of the adapted beam at the isocentre was adjustable between 5 and 11 mm full width at half maximum. The results demonstrate the feasibility/proof of the proposed range adaptation method for beam tracking from the beam quality point of view.


Asunto(s)
Magnetismo , Fenómenos Ópticos , Radioterapia/instrumentación , Estudios de Factibilidad , Método de Montecarlo , Radioterapia/métodos , Factores de Tiempo
6.
Med Phys ; 37(2): 449-60, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20229853

RESUMEN

Clinical outcomes of charged particle therapy are very promising. Currently, several dedicated centers that use scanning beam technology are either close to clinical use or under construction. Since scanned beam treatments of targets that move with respiration most likely result in marked local over- and underdosage due to interplay of target motion and dynamic beam application, dedicated motion mitigation techniques have to be employed. To date, the motion mitigation techniques, rescanning, beam gating, and beam tracking, have been proposed and tested in experimental studies. Rescanning relies on repeated irradiations of the target with the number of particles reduced accordingly per scan to statistically average local misdosage. Specific developments to prohibit temporal correlation between beam scanning and target motion will be required to guarantee adequate averaging. For beam gating, residual target motion within gating windows has to be mitigated in order to avoid local misdosage. Possibly the most promising strategy is to increase the overlap of adjacent particle pencil beams laterally as well as longitudinally to effectively reduce the sensitivity against small residual target motion. The most conformal and potentially most precise motion mitigation technique is beam tracking. Individual particle pencil beams have to be adapted laterally as well as longitudinally according to the target motion. Within the next several years, it can be anticipated that rescanning as well as beam gating will be ready for clinical use. For rescanning, treatment planning margins that incorporate the full extent of target motion as well as motion induced density variations in the beam paths will result in reduced target conformity of the applied dose distributions. Due to the limited precision of motion monitoring devices, it seems likely that beam gating will be used initially to mitigate interplay effects only but not to considerably decrease treatment planning margins. Then, in the next step, beam gating, based on more accurate motion monitoring systems, provides the possibility to restore target conformity as well as steep dose gradients due to reduced treatment planning margins. Accurate motion monitoring systems will be required for beam tracking. Even though beam tracking has already been successfully tested experimentally, full clinical implementation requires direct feedback of the actual target position in quasireal time to the treatment control system and can be anticipated to be several more years ahead.


Asunto(s)
Algoritmos , Predicción , Radioterapia de Iones Pesados , Movimiento , Radioterapia Asistida por Computador/tendencias , Radioterapia de Alta Energía/tendencias , Mecánica Respiratoria , Alemania
7.
Med Phys ; 36(9): 4230-43, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19810497

RESUMEN

PURPOSE: Clinically safe and effective treatment of intrafractionally moving targets with scanned ion beams requires dedicated delivery techniques such as beam tracking. Apart from treatment delivery, also appropriate methods for validation of the actual tumor irradiation are highly desirable, In this contribution the feasibility of four-dimensionally (space and time) resolved, motion-compensated in-beam positron emission tomography (4DibPET) was addressed in experimental studies with scanned carbon ion beams. METHODS: A polymethyl methracrylate block sinusoidally moving left-right in beam's eye view was used as target. Radiological depth changes were introduced by placing a stationary ramp-shaped absorber proximal of the moving target. Treatment delivery was compensated for motion by beam tracking. Time-resolved, motion-correlated in-beam PET data acquisition was performed during beam delivery with tracking the moving target and prolonged after beam delivery first with the activated target still in motion and, finally, with the target at rest. Motion-compensated 4DibPET imaging was implemented and the results were compared to a stationary reference irradiation of the same treatment field. Data were used to determine feasibility of 4DibPET but also to evaluate offline in comparison to in-beam PET acquisition. RESULTS: 4D in-beam as well as offline PET imaging was found to be feasible and offers the possibility to verify the correct functioning of beam tracking. Motion compensation of the imaged beta(+)-activity distribution allows recovery of the volumetric extension of the delivered field for direct comparison with the reference stationary condition. Observed differences in terms of lateral field extension and penumbra in the direction of motion were typically less than 1 mm for both imaging strategies in comparison to the corresponding reference distributions. However, in-beam imaging retained a better spatial correlation of the measured activity with the delivered dose. CONCLUSIONS: 4DibPET is a feasible and promising method to validate treatment delivery of scanned ion beams to moving targets. Further investigations will focus on more complex geometries and treatment planning studies with clinical data.


Asunto(s)
Iones/uso terapéutico , Tomografía de Emisión de Positrones/métodos , Radioterapia/métodos , Carbono/uso terapéutico , Simulación por Computador , Movimiento (Física) , Fantasmas de Imagen , Tomografía de Emisión de Positrones/instrumentación , Dosis de Radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Factores de Tiempo
8.
Phys Med Biol ; 54(16): 4849-62, 2009 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-19636085

RESUMEN

The technical performance of an integrated three-dimensional carbon ion pencil beam tracking system that was developed at GSI was investigated in phantom studies. Aim of the beam tracking system is to accurately treat tumours that are subject to respiratory motion with scanned ion beams. The current system provides real-time control of ion pencil beams to track a moving target laterally using the scanning magnets and longitudinally with a dedicated range shifter. The system response time was deduced to be approximately 1 ms for lateral beam tracking. The range shifter response time has been measured for various range shift amounts. A value of 16 +/- 2 ms was achieved for a water equivalent shift of 5 mm. An additional communication delay of 11 +/- 2 ms was taken into account in the beam tracking process via motion prediction. Accuracy of the lateral beam tracking was measured with a multi-wire position detector to < or =0.16 mm standard deviation. Longitudinal beam tracking accuracy was parameterized based on measured responses of the range shifter and required time durations to maintain a specific particle range. For example, 5 mm water equivalence (WE) longitudinal beam tracking results in accuracy of 1.08 and 0.48 mm WE in root mean square for time windows of 10 and 50 ms, respectively.


Asunto(s)
Movimiento , Radioterapia/métodos , Fantasmas de Imagen , Factores de Tiempo
9.
Int J Radiat Oncol Biol Phys ; 73(4): 1270-5, 2009 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-19251099

RESUMEN

PURPOSE: To demonstrate mitigation of the interplay effects of scanned particle beams and residual target motion within a gating window by increased overlap of pencil beams. METHODS AND MATERIALS: Lateral overlap was increased by increasing the pencil beam widths or by decreasing the distance between the pencil beams (scan grid). Longitudinal overlap was increased by reducing the distance between iso-range slices. For scanned carbon ion beams, simulation studies were performed and validated experimentally to determine the required parameters for different residual motion characteristics. The dose distributions were characterized by the maximal local deviations representing local over- and underdosage. RESULTS: For residual lateral motion, the local deviations were <5% for 2, 4, and 7 mm residual motion within the gating window for a 2-mm scan grid and pencil beams of 10, 14, and 18 mm full width at half maximum, respectively. Decreasing the iso-range slice distance from 3 mm to 1 mm effectively mitigated

Asunto(s)
Movimiento , Radioterapia/métodos , Aceleradores de Partículas , Dosificación Radioterapéutica , Película para Rayos X
10.
Med Image Comput Comput Assist Interv ; 12(Pt 1): 828-36, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-20426065

RESUMEN

In this paper we propose a novel similarity metric and a method for deformable registration of two images for a specific clinical application. The basic assumption in almost all deformable registration approaches is that there exist explicit correspondences between pixels across the two images. This principle is used to design image (dis)similarity metrics, such as sum of squared differences (SSD) or mutual information (MI). This assumption is strongly violated, for instance, within specific regions of images from abdominal or pelvic section of a patient taken at two different time points. Nevertheless, in some clinical applications, it is required to compute a smooth deformation field for all the regions within the image including the boundaries of such regions. In this paper, we propose a deformable registration method, which utilizes a priori intensity distributions of the regions delineated on one of the images to devise a new similarity measure that varies across regions of the image to establish a smooth and robust deformation field. We present validation results of the proposed method in mapping bladder, prostate, and rectum contours of computer tomography (CT) volumes of 10 patients taken for prostate cancer radiotherapy treatment planning and verification.


Asunto(s)
Imagenología Tridimensional/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Radioterapia Asistida por Computador/métodos , Técnica de Sustracción , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Inteligencia Artificial , Humanos , Masculino , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Radiat Oncol ; 3: 34, 2008 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-18854012

RESUMEN

BACKGROUND: Intrafractional motion results in local over- and under-dosage in particle therapy with a scanned beam. Scanned beam delivery offers the possibility to compensate target motion by tracking with the treatment beam. METHODS: Lateral motion components were compensated directly with the beam scanning system by adapting nominal beam positions according to the target motion. Longitudinal motion compensation to mitigate motion induced range changes was performed with a dedicated wedge system that adjusts effective particle energies at isocenter. RESULTS: Lateral compensation performance was better than 1% for a homogeneous dose distribution when comparing irradiations of a stationary radiographic film and a moving film using motion compensation. The accuracy of longitudinal range compensation was well below 1 mm. CONCLUSION: Motion compensation with scanned particle beams is technically feasible with high precision.


Asunto(s)
Movimiento (Física) , Planificación de la Radioterapia Asistida por Computador/instrumentación , Planificación de la Radioterapia Asistida por Computador/métodos , Sincrotrones , Simulación por Computador , Relación Dosis-Respuesta en la Radiación , Estudios de Factibilidad , Dosis de Radiación
12.
Int J Radiat Oncol Biol Phys ; 71(4): 1245-52, 2008 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-18472367

RESUMEN

PURPOSE: To assess the accuracy of maximum-intensity volumes (MIV) for fast contouring of lung tumors including respiratory motion. METHODS AND MATERIALS: Four-dimensional computed tomography (4DCT) data of 10 patients were acquired. Maximum-intensity volumes were constructed by assigning the maximum Hounsfield unit in all CT volumes per geometric voxel to a new, synthetic volume. Gross tumor volumes (GTVs) were contoured on all CT volumes, and their union was constructed. The GTV with all its respiratory motion was contoured on the MIV as well. Union GTVs and GTVs including motion were compared visually. Furthermore, planning target volumes (PTVs) were constructed for the union of GTVs and the GTV on MIV. These PTVs were compared by centroid position, volume, geometric extent, and surface distance. RESULTS: Visual comparison of GTVs demonstrated failure of the MIV technique for 5 of 10 patients. For adequate GTV(MIV)s, differences between PTVs were <1.0 mm in centroid position, 5% in volume, +/-5 mm in geometric extent, and +/-0.5 +/- 2.0 mm in surface distance. These values represent the uncertainties for successful MIV contouring. CONCLUSION: Maximum-intensity volumes are a good first estimate for target volume definition including respiratory motion. However, it seems mandatory to validate each individual MIV by overlaying it on a movie loop displaying the 4DCT data and editing it for possible inadequate coverage of GTVs on additional 4DCT motion states.


Asunto(s)
Imagenología Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Movimiento , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Artefactos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
Med Phys ; 35(2): 775-81, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18383700

RESUMEN

Deformable registration is needed for a variety of tasks in establishing the voxel correspondence between respiratory phases. Most registration algorithms assume or imply that the deformation field is smooth and continuous everywhere. However, the lungs are contained within closed invaginated sacs called pleurae and are allowed to slide almost independently along the chest wall. This sliding motion is characterized by a discontinuous vector field, which cannot be generated using standard deformable registration methods. The authors have developed a registration method that can create discontinuous vector fields at the boundaries of anatomical subregions. Registration is performed independently on each subregion, with a boundary-matching penalty used to prevent gaps. This method was implemented and tested using both the B-spline and Demons registration algorithms in the Insight Segmentation and Registration Toolkit. The authors have validated this method on four patient 4DCT data sets for registration of the end-inhalation and end-exhalation volumes. Multiple experts identified homologous points in the lungs and along the ribs in the two respiratory phases. Statistical analyses of the mismatch of the homologous points before and after registration demonstrated improved overall accuracy for both algorithms.


Asunto(s)
Algoritmos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Imagenología Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Técnica de Sustracción , Tomografía Computarizada por Rayos X/métodos , Humanos , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación
14.
Phys Med Biol ; 53(9): 2253-65, 2008 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-18401063

RESUMEN

Scanned particle beams and target motion interfere. This interplay leads to deterioration of the dose distribution. Experiments and a treatment planning study were performed to investigate interplay. Experiments were performed with moving radiographic films for different motion parameters. Resulting dose distributions were analyzed for homogeneity and dose coverage. The treatment planning study was based on the time-resolved computed tomography (4DCT) data of five lung tumor patients. Treatment plans with margins to account for respiratory motion were optimized, and resulting dose distributions for 108 different motion parameters for each patient were calculated. Data analysis for a single fraction was based on dose-volume histograms and the volume covered with 95% of the planned dose. Interplay deteriorated dose conformity and homogeneity (1-standard deviation/mean) in the experiments as well as in the treatment-planning study. The homogeneity on radiographic films was below approximately 80% for motion amplitudes of approximately 15 mm. For the treatment-planning study based on patient data, the target volume receiving at least 95% of the prescribed dose was on average (standard deviation) 71.0% (14.2%). Interplay of scanned particle beams and moving targets has severe impact on the resulting dose distributions. Fractionated treatment delivery potentially mitigates at least parts of these interplay effects. However, especially for small fraction numbers, e.g. hypo-fractionation, treatment of moving targets with scanned particle beams requires motion mitigation techniques such as rescanning, gating, or tracking.


Asunto(s)
Neoplasias Pulmonares/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Artefactos , Fraccionamiento de la Dosis de Radiación , Humanos , Movimiento (Física) , Movimiento , Aceleradores de Partículas , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/instrumentación , Radioterapia de Intensidad Modulada/instrumentación , Radioterapia de Intensidad Modulada/métodos , Reproducibilidad de los Resultados , Factores de Tiempo , Tomografía Computarizada por Rayos X/instrumentación
15.
Radiat Oncol ; 2: 24, 2007 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-17608919

RESUMEN

At Gesellschaft für Schwerionenforschung (GSI) more than 330 patients have been treated with scanned carbon ion beams in a pilot project. To date, only stationary tumors have been treated. In the presence of motion, scanned ion beam therapy is not yet possible because of interplay effects between scanned beam and target motion which can cause severe mis-dosage. We have started a project to treat tumors that are subject to respiratory motion. A prototype beam application system for target tracking with the scanned pencil beam has been developed and commissioned. To facilitate treatment planning for tumors that are subject to organ motion, we have extended our standard treatment planning system TRiP to full 4D functionality. The 4D version of TRiP allows to calculate dose distributions in the presence of motion. Furthermore, for motion mitigation techniques tracking, gating, rescanning, and internal margins optimization of treatment parameters has been implemented. 4D calculations are based on 4D computed tomography data, deformable registration maps, organ motion traces, and beam scanning parameters.We describe the methods of our 4D treatment planning approach and demonstrate functionality of the system for phantom as well as patient data.


Asunto(s)
Tomografía Computarizada Cuatridimensional/métodos , Iones , Planificación de la Radioterapia Asistida por Computador/métodos , Carbono , Diseño de Equipo , Humanos , Modelos Estadísticos , Movimiento (Física) , Fantasmas de Imagen , Proyectos Piloto , Dosificación Radioterapéutica , Respiración , Sincrotrones , Factores de Tiempo , Tomografía Computarizada por Rayos X/métodos
16.
Front Radiat Ther Oncol ; 40: 59-71, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17641502

RESUMEN

Four-dimensional CT acquisition is commercially available, and provides important information on the shape and trajectory of the tumor and normal tissues. The primary advantage of four-dimensional imaging over light breathing helical scans is the reduction of motion artifacts during scanning that can significantly alter tumor appearance. Segmentation, image registration, visualization are new challenges associated with four-dimensional data sets because of the overwhelming increase in the number of images. Four-dimensional dose calculations, while currently laborious, provide insights into dose perturbations due to organ motion. Imaging before treatment (image guidance) improves accuracy of radiation delivery, and recording transmission images can provide a means of verifying gated delivery.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X , Artefactos , Humanos , Dosificación Radioterapéutica
17.
Radiat Oncol ; 2: 14, 2007 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-17381831

RESUMEN

BACKGROUND: The precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration can cause relevant differences between treatment planning and treatment delivery. METHODS: Calibration data for several soft tissues were measured repeatedly to assess the accuracy of range calibration. Samples of fresh animal tissues including fat, brain, kidney, liver, and several muscle tissues were used. First, samples were CT scanned. Then carbon ion radiographic measurements were performed at several positions. Residual ranges behind the samples were compared to ranges in water. RESULTS: Based on the measured data the accuracy of the current Hounsfield look-up table for range calibration of soft tissues is 0.2 +/- 1.2%. Accuracy in range calibration of 1% corresponds to approximately 1 mm carbon ion range control in 10 cm water equivalent depth which is comparable to typical treatment depths for head and neck tumors. CONCLUSION: Carbon ion ranges can be controlled within approximately 1 mm in soft tissue for typical depths of head and neck treatments.


Asunto(s)
Carbono , Iones , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia/métodos , Tomografía Computarizada por Rayos X/métodos , Tejido Adiposo/efectos de la radiación , Animales , Encéfalo/efectos de la radiación , Calibración , Riñón/efectos de la radiación , Hígado/efectos de la radiación , Dosis de Radiación , Reproducibilidad de los Resultados , Porcinos
18.
Med Phys ; 34(12): 4768-71, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18196804

RESUMEN

Treatment of moving targets with scanned particle beams results in local over- and under-dosage due to interplay of beam and target motion. To mitigate the impact of respiratory motion, a motion tracking system has been developed and integrated in the therapy control system at Gesellschaft für Schwerionenforschung. The system adapts pencil beam positions as well as the beam energy according to target motion to irradiate the planned position. Motion compensation performance of the tracking system was assessed by measurements with radiographic films and a 3D array of 24 ionization chambers. Measurements were performed for stationary detectors and moving detectors using the tracking system. Film measurements showed comparable homogeneity inside the target area. Relative differences of 3D dose distributions within the target volume were 1 +/- 2% with a maximum of 4%. Dose gradients and dose to surrounding areas were in good agreement. The motion tracking system successfully preserved dose distributions delivered to moving targets and maintained target conformity.


Asunto(s)
Partículas Elementales , Movimiento , Radiometría/métodos , Respiración , Dosis de Radiación , Película para Rayos X
19.
Med Phys ; 33(11): 4423-30, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17153421

RESUMEN

Four-dimensional radiotherapy requires deformable registration to track delivered dose across varying anatomical states. Deformable registration based on B-splines was implemented to register 4D computed tomography data to a reference respiratory phase. To assess registration performance, anatomical landmarks were selected across ten respiratory phases in five patients. These point landmarks were transformed according to global registration parameters between different respiratory phases. Registration uncertainties were computed by subtraction of transformed and reference landmark positions. The selection of appropriate registration masks to separate independently moving anatomical subunits is crucial to registration performance. The average registration error for five landmarks for each of five patients was 2.1 mm. This level of accuracy is acceptable for most radiotherapy applications.


Asunto(s)
Artefactos , Imagenología Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Mecánica Respiratoria , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Algoritmos , Inteligencia Artificial , Humanos , Masculino , Persona de Mediana Edad , Reconocimiento de Normas Patrones Automatizadas/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
Med Phys ; 33(8): 2809-18, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16964857

RESUMEN

This study investigated the sensitivity of static planning of intensity-modulated beams (IMBs) to intrafraction deformable organ motion and assessed whether smoothing of the IMBs at the treatment-planning stage can reduce this sensitivity. The study was performed with a 4D computed tomography (CT) data set for an IMRT treatment of a patient with liver cancer. Fluence profiles obtained from inverse-planning calculations on a standard reference CT scan were redelivered on a CT scan from the 4D data set at a different part of the breathing cycle. The use of a nonrigid registration model on the 4D data set additionally enabled detailed analysis of the overall intrafraction motion effects on the IMRT delivery during free breathing. Smoothing filters were then applied to the beam profiles within the optimization process to investigate whether this could reduce the sensitivity of IMBs to intrafraction organ motion. In addition, optimal fluence profiles from calculations on each individual phase of the breathing cycle were averaged to mimic the convolution of a static dose distribution with a motion probability kernel and assess its usefulness. Results from nonrigid registrations of the CT scan data showed a maximum liver motion of 7 mm in superior-inferior direction for this patient. Dose-volume histogram (DVH) comparison indicated a systematic shift when planning treatment on a motion-frozen, standard CT scan but delivering over a full breathing cycle. The ratio of the dose to 50% of the normal liver to 50% of the planning target volume (PTV) changed up to 28% between different phases. Smoothing beam profiles with a median-window filter did not overcome the substantial shift in dose due to a difference in breathing phase between planning and delivery of treatment. Averaging of optimal beam profiles at different phases of the breathing cycle mainly resulted in an increase in dose to the organs at risk (OAR) and did not seem beneficial to compensate for organ motion compared with using a large margin. Additionally, the results emphasized the need for 4D CT scans when aiming to reduce the internal margin (IM). Using only a single planning scan introduces a systematic shift in the dose distribution during delivery. Smoothing beam profiles either based on a single scan or over the different breathing phases was not beneficial for reducing this shift.


Asunto(s)
Imagenología Tridimensional/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Movimiento , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Tomografía Computarizada por Rayos X/métodos , Vísceras/fisiopatología , Carga Corporal (Radioterapia) , Dosificación Radioterapéutica , Efectividad Biológica Relativa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS