Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
2.
Neuroimage ; 163: 342-357, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28951350

RESUMEN

Micro-electrocorticograph (µECoG) arrays offer the flexibility to record local field potentials (LFPs) from the surface of the cortex, using high density electrodes that are sub-mm in diameter. Research to date has not provided conclusive evidence for the underlying signal generation of µECoG recorded LFPs, or if µECoG arrays can capture network activity from the cortex. We studied the pervading view of the LFP signal by exploring the spatial scale at which the LFP can be considered elemental. We investigated the underlying signal generation and ability to capture functional networks by implanting, µECoG arrays to record sensory-evoked potentials in four rats. The organization of the sensory cortex was studied by analyzing the sensory-evoked potentials with two distinct modeling techniques: (1) The volume conduction model, that models the electrode LFPs with an electrostatic representation, generated by a single cortical generator, and (2) the dynamic causal model (DCM), that models the electrode LFPs with a network model, whose activity is generated by multiple interacting cortical sources. The volume conduction approach modeled activity from electrodes separated < 1000 µm, with reasonable accuracy but a network model like DCM was required to accurately capture activity > 1500 µm. The extrinsic network component in DCM was determined to be essential for accurate modeling of observed potentials. These results all point to the presence of a sensory network, and that µECoG arrays are able to capture network activity in the neocortex. The estimated DCM network models the functional organization of the cortex, as signal generators for the µECoG recorded LFPs, and provides hypothesis-testing tools to explore the brain.


Asunto(s)
Mapeo Encefálico/métodos , Potenciales Evocados Somatosensoriales/fisiología , Modelos Neurológicos , Corteza Somatosensorial/fisiología , Animales , Electrocorticografía , Ratas
3.
J Vis Exp ; (60)2012 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-22395095

RESUMEN

Electrical impedance spectroscopy (EIS) and cyclic voltammetry (CV) measure properties of the electrode-tissue interface without additional invasive procedures, and can be used to monitor electrode performance over the long term. EIS measures electrical impedance at multiple frequencies, and increases in impedance indicate increased glial scar formation around the device, while cyclic voltammetry measures the charge carrying capacity of the electrode, and indicates how charge is transferred at different voltage levels. As implanted electrodes age, EIS and CV data change, and electrode sites that previously recorded spiking neurons often exhibit significantly lower efficacy for neural recording. The application of a brief voltage pulse to implanted electrode arrays, known as rejuvenation, can bring back spiking activity on otherwise silent electrode sites for a period of time. Rejuvenation alters EIS and CV, and can be monitored by these complementary methods. Typically, EIS is measured daily as an indication of the tissue response at the electrode site. If spikes are absent in a channel that previously had spikes, then CV is used to determine the charge carrying capacity of the electrode site, and rejuvenation can be applied to improve the interface efficacy. CV and EIS are then repeated to check the changes at the electrode-tissue interface, and neural recordings are collected. The overall goal of rejuvenation is to extend the functional lifetime of implanted arrays.


Asunto(s)
Espectroscopía Dieléctrica/métodos , Técnicas Electroquímicas/métodos , Neuronas/fisiología , Animales , Espectroscopía Dieléctrica/instrumentación , Técnicas Electroquímicas/instrumentación , Electrodos Implantados , Ratas , Interfaz Usuario-Computador
4.
Artículo en Inglés | MEDLINE | ID: mdl-19964122

RESUMEN

We present approaches for using thin film polymeric electrode arrays for use in applications of minimally invasive neurological monitoring. The flexibility and unique surface properties of the thin-film polyimide substrate in combination with a compact device platform make them amenable to a variety of surgical implantation procedures. Using a rapid-prototyping and fabrication technique, arrays of various geometries can be fabricated within a week. In this paper we test two different approaches for deploying electrode arrays through small cranial openings.


Asunto(s)
Potenciales de Acción/fisiología , Encéfalo/fisiología , Electrodos Implantados , Electroencefalografía/instrumentación , Membranas Artificiales , Animales , Cadáver , Módulo de Elasticidad , Conductividad Eléctrica , Diseño de Equipo , Análisis de Falla de Equipo , Macaca mulatta , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA