Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Circ Cardiovasc Interv ; 5(3): 365-71, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22693347

RESUMEN

BACKGROUND: It remains unclear whether there are differences in the safety and efficacy outcomes between everolimus-eluting stents (EES) and sirolimus-eluting stents (SES) in contemporary practice. METHODS AND RESULTS: We prospectively enrolled 6166 consecutive patients who received EES (3081 patients) and SES (3085 patients) between April 2008 and June 2010, using data from the Interventional Cardiology Research In-Cooperation Society-Drug-Eluting Stents Registry. The primary end point was a composite of death, nonfatal myocardial infarction (MI), or target-vessel revascularization (TVR). At 2 years of follow-up, the 2 study groups did not differ significantly in crude risk of the primary end point (12.1% for EES versus 12.4% for SES; HR, 0.97; 95% CI, 0.84-1.12, P=0.66). After adjustment for differences in baseline risk factors, the adjusted risk for the primary end point remained similar for the 2 stent types (HR, 0.96; 95% CI, 0.82-1.12, P=0.60). There were also no differences between the stent groups in the adjusted risks of the individual component of death (HR, 0.93; 95% CI, 0.67-1.30, P=0.68), MI (HR, 0.97; 95% CI, 0.79-1.18, P=0.74), and TVR (HR, 1.10; 95% CI, 0.82-1.49, P=0.51). The adjusted risk of stent thrombosis also was similar (HR, 1.16; 95% CI, 0.47-2.84, P=0.75). CONCLUSIONS: In contemporary practice of percutaneous coronary intervention procedures, the unrestricted use of EES and SES showed similar rates of safety and efficacy outcomes with regard to death, MI, sent thrombosis, and TVR. Future longer-term follow-up is needed to better define the relative benefits of these drug-eluting stents. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01070420.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Stents Liberadores de Fármacos , Sirolimus/análogos & derivados , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Distribución de Chi-Cuadrado , Trombosis Coronaria/etiología , Everolimus , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , República de Corea , Medición de Riesgo , Factores de Riesgo , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA