Asunto(s)
Humanos , Cirugía Vitreorretiniana , Cirujanos , Oftalmólogos , Retina/cirugía , Enfermedades de la Retina/cirugíaRESUMEN
PURPOSE: To present a case of stellate nonhereditary idiopathic foveomacular retinoschisis (SNIFR) resolution associated with vitreomacular adherence (VMA) release and propose a potential contributing association between SNIFR and vitreomacular interactions. OBSERVATIONS: A 67-year-old female patient was diagnosed and followed for SNIFR in OD with spectral-domain optical coherence tomography (SD-OCT) scans at presentation and subsequent visits at 3, 6, 16 and 22 months. VMA and foveomacular retinoschisis remained unchanged on SD-OCT during the first 6 months of the follow-up. At 16-month follow-up visit, SD-OCT revealed VMA release and an important improvement of the macular schisis. At 22 months of follow-up, SNIFR cavities completely resolved in the presence of posterior hyaloid separation from the macular area without any adjunct treatment. The authors could not identify any other possible cause to justify the resolution of SNIFR other than VMA release in this case. Patient did not undergo any treatment for OD other than phacoemulsification 3 months after initial visit. CONCLUSION: The present case illustrates with SD-OCT scans a possible association between SNIFR resolution and VMA release, highlighting a potential tractional component of the posterior vitreous on the internal limiting membrane and consequent glial cells stretching with schisis formation.
RESUMEN
BACKGROUND: The purpose of the current study is to report the anatomical and functional results of off-label human amniotic membrane graft as primary intervention to repair large to giant macular holes and in reoperations when wide internal limiting membrane peeling was unsuccessful. METHODS: Retrospective chart review was carried out in five different centers to identify all cases that had undergone off-label human amniotic membrane graft for the treatment of large or failed macular holes (MH). Data collected included age, gender, other concomitant diagnosis, symptoms duration, lens status, number of previous surgeries, macular hole measurements (minimum and base linear diameters), mean post-operative follow-up (months), and pre- and post-operative best corrected visual acuity (BCVA). Main outcome measures were anatomical MH closure rates and final BCVA (in logMAR). Nonparametric Wilcoxon rank-sum test was used because the data was not normally distributed, a P values < 0.05 were considered statistically significant. RESULTS: Nineteen eyes of 19 patients were identified and included in the study. Mean age was 66.21 ± 14.96 years and predominantly females (84%). All eyes had successfully closed MH with a single intervention with no recurrences during a mean of 9 ± 3.87 months follow-up. The median BCVA in logMAR preoperative was 1.30 ± 0.44 (0.80-2.0), approximately 20/400 on Snellen chart and the median BCVA in logMAR postoperative was 1.0 ± 0.72 (0.4-3.0) approximately 20/200 (p < 0.0001) with median of three lines of visual improvement. CONCLUSION: The use of human amniotic membrane graft seems to be a viable and effective alternative for the treatment of large and persistent macular holes. However, further larger prospective controlled studies are necessary to confirm our preliminary results of this new surgical technique.
RESUMEN
BACKGROUND: To perform a microbiological contamination analysis of the vitreous during office-based micro-incision vitrectomy surgery (MIVS) assessing whether the bacteria detected correlated with patient's ocular conjunctival flora. METHODS: This is a prospective, interventional, nonrandomized case series of patients undergoing office-based MIVS, anti-VEGF, and dexamethasone intravitreal injections (triple therapy) for the treatment of wet age-related macular degeneration (AMD) and diabetic macular edema (DME).All patients were operated at a small procedure room in an ambulatory clinic of the Department of Ophthalmology, University of Montreal, Quebec, Canada. Conjunctival samples were done before placing the sclerotomies. The MIVS was done with a 23-gauge retractable vitrector, a 27-gauge infusion line, and a 29-gauge chandelier. Undiluted and diluted vitreous were collected for aerobic, anaerobic and fungal cultures. Outcomes measured were bacterial species identification within samples collected from the conjunctiva and the vitreous. RESULTS: Thirty-seven patients (37 eyes) were recruited and completed over 17 months of follow-up. Twenty-eight had wet AMD and nine had DME. There were 13 men and 24 women, with a mean age of 78 years. Eighteen patients (46%) had culture positive conjunctival flora. Twenty-six bacterial colonies were tabulated in total from the conjunctival swabs. All bacteria detected were gram-positive bacteria (100%), most commonly: Staphylococcus epidermitis in 11 (42%) and Corynebacterium sp. in 6 (23%). Only 1/18 patients had more than 3 species isolated, 6/18 patients had 2 species and 11/18 patients had 1 species identified on the conjunctival swab. Only 1 of the 37 undiluted midvitreous samples was culture positive, equating to a contamination rate of 2.7%. None of the diluted vitreous samples were culture positive. All cultures were negative for fungus. No serious postoperative complications occurred, including bacterial endophthalmitis, choroidal detachment, and retinal detachment. CONCLUSION: This preliminary study of office-based MIVS gives us insights on the ocular surface microbial profile and vitreous contamination rate of performing such procedures outside the OR-controlled environment. Our initial results seem to indicate that there is little risk of bacterial translocation and contamination from the conjunctiva into the vitreous. Therefore, if endophthalmitis occurs post-operatively, the source may likely arise after the procedure. Larger studies are needed to confirm our data.
Asunto(s)
Endoftalmitis/microbiología , Infecciones Bacterianas del Ojo/microbiología , Degeneración Macular/cirugía , Microcirugia/efectos adversos , Infección de la Herida Quirúrgica/microbiología , Vitrectomía/efectos adversos , Cuerpo Vítreo/microbiología , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Ambulatorios/efectos adversos , Bacterias/aislamiento & purificación , Brasil/epidemiología , Conjuntiva/microbiología , Endoftalmitis/epidemiología , Infecciones Bacterianas del Ojo/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Infección de la Herida Quirúrgica/epidemiología , Vitrectomía/métodos , Cuerpo Vítreo/cirugíaRESUMEN
Purpose. To investigate the in vivo incision architecture using spectral domain optical coherence tomography (SD-OCT) in 23-gauge and 25-gauge transconjunctival sutureless pars plana vitrectomy (TSPPV). Methods. A prospective observational study of 22 eyes of 22 patients that underwent three-port 25-gauge (10 eyes) or 23-gauge (12 eyes) TSPPV was performed. The three sclerotomies sites in each eye were analyzed by Corneal Adapter Model (CAM) RTVue SD-OCT (Optovue Inc., Fremont, CA, USA) with wound cross-section images (longitudinal and transversal) on days 1, 7, and 30 postoperatively. Transversal and longitudinal length, location, angle between the conjunctival surface tangent and the incision plane, and architecture deformations were evaluated. Results. All patients (22 eyes) completed the study and surgeries lasted less than 60 minutes. All wounds were obliquely performed, 23-gauge mean angle was 23 ± 5°, and 25-gauge angule was 21 ± 4°. Twenty-three-gauge sclerotomy transversal mean length was 1122 ± 242 µ m and 25-gauge transversal sclerotomy mean length was 977 ± 174 µ m; 23-gauge longitudinal mean length was 363 ± 42 µ m and 25-gauge longitudinal sclerotomy mean length was 234 ±19 µ m; 23-gauge open wound thickness mean was 61 ± 28 µ m and 25-gauge open wound thickness mean was 22 ± 6 µ m. All results were statistically significant (P < 0.05). No vitreous incarceration or silicone oil residue was observed in incision sites with both gauges. Conclusions. The 23-gauge and 25-gauge architectural wound constructions were well visualized using CAM SD-OCT. Statistical differences between the two gauges were observed throughout the study period.
RESUMEN
PURPOSE: To describe a novel surgical technique for drainage of bullous serous and hemorrhagic choroidal detachments. METHODS: A prospective, consecutive case series of 6 eyes with serous and/or hemorrhagic choroidal detachments secondary to intraocular surgery was documented to evaluate the feasibility of using the 25-gauge and 20-gauge transconjunctival trocar/cannula systems to drain choroidal detachments. Two eyes had expulsive hemorrhagic choroidal detachments and 4 eyes had serous choroidal detachments after glaucoma surgeries. A 25-gauge infusion line was placed in the anterior chamber. A 20-gauge (in eyes with hemorrhagic choroidal detachments) or a 25-gauge (in eyes with serous detachments) trocar/cannula system was inserted into the suprachoroidal space 7.0 mm from limbus. After drainage, the cannulas were removed and no sutures were placed. Pars plana vitrectomy was performed only in eyes with concomitant pathology that demanded the additional procedure. The primary outcome measure was presence of choroidal detachment at 1 week, 2 weeks, and 1 month postoperatively. Secondary outcome measures were visual acuity at 6 months and intraocular pressure at 1 week and 1, 3, and 6 months postoperatively. RESULTS: Drainage of hemorrhagic choroidal detachments resulted in resolution of the detachments by 1 month postoperatively. In eyes with serous detachments, resolution was achieved by 1 week postdrainage. In both groups, intraocular pressure increased to at least 10 mmHg by postoperative Week 1. The visual acuity improved in all eyes. No complications related to the transconjunctival technique were noted. CONCLUSION: Transconjunctival drainage of serous and hemorrhagic choroidal detachments seems to be a feasible and simple surgical option with minimal scleral and conjunctival damage. Pars plana vitrectomy may not be necessary when draining choroidal detachments in this manner.