Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
N Engl J Med ; 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39216096

RESUMEN

BACKGROUND: One third of patients undergoing transcatheter aortic-valve implantation (TAVI) have an indication for oral anticoagulation owing to concomitant diseases. Interruption of oral anticoagulation during TAVI may decrease the risk of bleeding, whereas continuation may decrease the risk of thromboembolism. METHODS: We conducted an international, open-label, randomized, noninferiority trial involving patients who were receiving oral anticoagulants and were planning to undergo TAVI. Patients were randomly assigned in a 1:1 ratio to periprocedural continuation or interruption of oral anticoagulation. The primary outcome was a composite of death from cardiovascular causes, stroke from any cause, myocardial infarction, major vascular complications, or major bleeding within 30 days after TAVI. RESULTS: A total of 858 patients were included in the modified intention-to-treat population: 431 were assigned to continuation and 427 to interruption of oral anticoagulation. A primary-outcome event occurred in 71 patients (16.5%) in the continuation group and in 63 (14.8%) in the interruption group (risk difference, 1.7 percentage points; 95% confidence interval [CI], -3.1 to 6.6; P = 0.18 for noninferiority). Thromboembolic events occurred in 38 patients (8.8%) in the continuation group and in 35 (8.2%) in the interruption group (risk difference, 0.6 percentage points; 95% CI, -3.1 to 4.4). Bleeding occurred in 134 patients (31.1%) in the continuation group and in 91 (21.3%) in the interruption group (risk difference, 9.8 percentage points; 95% CI, 3.9 to 15.6). CONCLUSIONS: In patients undergoing TAVI with a concomitant indication for oral anticoagulation, periprocedural continuation was not noninferior to interruption of oral anticoagulation during TAVI with respect to the incidence of a composite of death from cardiovascular causes, stroke, myocardial infarction, major vascular complications, or major bleeding at 30 days. (Funded by the Netherlands Organization for Health Research and Development and the St. Antonius Research Fund; POPular PAUSE TAVI ClinicalTrials.gov number, NCT04437303.).

2.
JACC Cardiovasc Interv ; 17(11): 1311-1321, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38795093

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.


Asunto(s)
Anticoagulantes , Apéndice Atrial , Fibrilación Atrial , Cateterismo Cardíaco , Contraindicaciones de los Medicamentos , Accidente Cerebrovascular Isquémico , Sistema de Registros , Humanos , Apéndice Atrial/fisiopatología , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/mortalidad , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/terapia , Femenino , Masculino , Anticoagulantes/efectos adversos , Anticoagulantes/administración & dosificación , Anciano , Factores de Riesgo , Medición de Riesgo , Anciano de 80 o más Años , Factores de Tiempo , Administración Oral , Accidente Cerebrovascular Isquémico/prevención & control , Accidente Cerebrovascular Isquémico/mortalidad , Accidente Cerebrovascular Isquémico/diagnóstico , Accidente Cerebrovascular Isquémico/etiología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Insuficiencia del Tratamiento , Hemorragia/inducido químicamente , Recurrencia , Persona de Mediana Edad , Estudios Retrospectivos , Europa (Continente)
3.
Lancet ; maio.2024.
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1555077

RESUMEN

BACKGROUND Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1•5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2­4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10•44% and assuming an event rate of 26•10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80•0 years (SD 5•7) for those treated with the Myval THV and 80•4 years (5•4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2•6% [IQR 1•7­4•0] vs contemporary 2•6% [1•7­4•0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of ­2•3% (one-sided upper 95% CI 3•8, pnon-inferiority<0•0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days.

4.
Lancet ; 403(10445): 2695-2708, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38795719

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
5.
Am Heart J ; 269: 158-166, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38163616

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment option for patients with severe aortic valve stenosis, but is still associated with relatively high rates of pacemaker implantation and paravalvular regurgitation. Routine preoperative computed tomography (CT) combined with patient-specific computer modelling can predict the interaction between the TAVI device and the patient's unique anatomy, allowing physicians to assess the risk for paravalvular regurgitation and conduction disorders in advance to the procedure. The aim of this trial is to assess potential improvement in the procedural outcome of TAVI by applying CT-based patient-specific computer simulations in patients with suitable anatomy for TAVI. METHODS: The GUIDE-TAVI trial is an international multicenter randomized controlled trial including patients accepted for TAVI by the Heart Team. Patients enrolled in the study will be randomized into 2 arms of each 227 patients. In patients randomized to the use of FEops HEARTGuide (FHG), patient-specific computer simulation with FHG is performed in addition to routine preoperative CT imaging and results of the FHG are available to the operator(s) prior to the scheduled intervention. In patients randomized to no use of FHG, only routine preoperative CT imaging is performed. The primary objective is to evaluate whether the use of FHG will reduce the incidence of mild to severe PVR, according to the Valve Academic Research Consortium 3. Secondary endpoints include the incidence of new conduction disorders requiring permanent pacemaker implantation, the difference between preoperative and final selected valve size, the difference between target and final implantation depth, change of preoperative decision, failure to implant valve, early safety composite endpoint and quality of life. CONCLUSIONS: The GUIDE-TAVI trial is the first multicenter randomized controlled trial to evaluate the value of 3-dimensional computer simulations in addition to standard preprocedural planning in TAVI procedures.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Simulación por Computador , Calidad de Vida , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada por Rayos X/efectos adversos , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos
6.
EuroIntervention ; 19(9): 766-771, 2023 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-37605804

RESUMEN

About one-third of patients undergoing transcatheter aortic valve implantation (TAVI) use oral anticoagulants (OAC), mainly due to atrial fibrillation. General guidelines advise interrupting OAC in patients with a high risk of bleeding undergoing interventions. However, preliminary observational data suggest that the continuation of OAC during TAVI is safe and may reduce the risk of periprocedural thromboembolic events. The Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation (POPular PAUSE TAVI) is a multicentre, randomised clinical trial with open-label treatment and blinded endpoint assessment. Patients are randomised 1:1 to periprocedural continuation versus interruption of OAC and are stratified for vitamin K antagonist or direct oral anticoagulant use. The primary endpoint is a composite of cardiovascular mortality, all stroke, myocardial infarction, major vascular complications and type 2-4 bleeding within 30 days after TAVI, according to the Valve Academic Research Consortium-3 criteria. Secondary endpoints include separate individual and composite outcomes, quality of life and cost-effectiveness. Since continuation of OAC is associated with the ancillary benefit that it simplifies periprocedural management, the primary outcome is first analysed for non-inferiority; if non-inferiority is proven, superiority will be tested. Recruitment started in November 2020, and the trial will continue until a total of 858 patients have been included and followed for 90 days. In summary, POPular PAUSE TAVI is the first randomised clinical trial to assess the safety and efficacy of periprocedural continuation versus interruption of OAC in patients undergoing TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Calidad de Vida , Anticoagulantes/uso terapéutico , Hemorragia , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de Riesgo
7.
Heart Rhythm O2 ; 4(5): 298-308, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37323993

RESUMEN

Background: Percutaneous left atrial appendage occlusion (LAAO) is an alternative to anticoagulation in the prevention of stroke in patients with nonvalvular atrial fibrillation, especially in patients with a contraindication for oral anticoagulation therapy (OAT). Objective: The study sought to obtain long-term patient outcomes after successful LAAO in everyday clinical practice. Methods: In this single-center registry spanning over 10 years, data of all consecutive patients that underwent percutaneous LAAO were collected. Observed thromboembolic and major bleeding event rates after successful LAAO during follow-up were compared with expected event rates based on CHA2DS2-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category) and HAS-BLED (hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol) scores. Furthermore, anticoagulation and antiplatelet use during follow-up was evaluated. Results: Of 230 patients scheduled for LAAO (38% women, 69.5 ± 8.2 years of age, CHA2DS2-VASc score 3.9 ± 1.6, HAS-BLED score 2.9 ± 1.0), 218 patients had a successful implantation (95%) with a follow-up duration of 5.2 ± 3.1 years. The procedure was combined with catheter ablation in 52% of the patients. Fifty thromboembolic complications (24 ischemic stroke, 26 transient ischemic attack) were observed during follow-up in 40 (18%) of 218 patients. Ischemic strokes occurred with a rate of 2.1 per 100 patient-years, accounting for a 66% relative risk reduction compared with the CHA2DS2-VASc predicted event rate. Device-related thrombus was observed in 5 (2%) patients. Sixty-five nonprocedural major bleeding complications occurred in 24 (11%) of 218 patients with a rate of 5.7 per 100-patient years, which is comparable to estimated HAS-BLED-bleeding rates under OAT use. At end of follow-up 71% of all patients were on single antiplatelet or no antiplatelet or anticoagulation treatment, while 29% were on OAT. Conclusion: Thromboembolic event rates during long-term follow-up after successful LAAO remained consistently lower than expected supporting the efficacy of LAAO.

10.
Sci Rep ; 11(1): 6425, 2021 03 19.
Artículo en Inglés | MEDLINE | ID: mdl-33742077

RESUMEN

Invasive fractional flow reserve (FFR) adoption remains low mainly due to procedural and operator related factors as well as costs. Alternatively, quantitative flow ratio (QFR) achieves a high accuracy mainly outside the intermediate zone without the need for hyperaemia and wire-use. We aimed to determine the diagnostic performance of QFR and to evaluate a QFR-FFR hybrid strategy in which FFR is measured only in the intermediate zone. This retrospective study included 289 consecutive patients who underwent invasive coronary angiography and FFR. QFR was calculated for all vessels in which FFR was measured. The QFR-FFR hybrid approach was modelled using the intermediate zone of 0.77-0.87 in which FFR-measurements are recommended. The sensitivity, specificity, and accuracy on a per vessel-based analysis were 84.6%, 86.3% and 85.6% for QFR and 88.0%, 92.9% and 90.3% for the QFR-FFR hybrid approach. The diagnostic accuracy of QFR-FFR hybrid strategy with invasive FFR measurement was 93.4% and resulted in a 56.7% reduction in the need for FFR. QFR has a good correlation and agreement with invasive FFR. A hybrid QFR-FFR approach could extend the use of QFR and reduces the proportion of invasive FFR-measurements needed while improving accuracy.


Asunto(s)
Toma de Decisiones Clínicas/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Imagenología Tridimensional/métodos , Anciano , Velocidad del Flujo Sanguíneo , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Exactitud de los Datos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
12.
Circulation ; 142(19): 1799-1807, 2020 11 10.
Artículo en Inglés | MEDLINE | ID: mdl-32862716

RESUMEN

BACKGROUND: Approximately 15% of saphenous vein grafts (SVGs) occlude during the first year after coronary artery bypass graft surgery (CABG) despite aspirin use. The POPular CABG trial (The Effect of Ticagrelor on Saphenous Vein Graft Patency in Patients Undergoing Coronary Artery Bypass Grafting Surgery) investigated whether ticagrelor added to standard aspirin improves SVG patency at 1 year after CABG. METHODS: In this investigator-initiated, randomized, double-blind, placebo-controlled, multicenter trial, patients with ≥1 SVGs were randomly assigned (1:1) after CABG to ticagrelor or placebo added to standard aspirin (80 mg or 100 mg). The primary outcome was SVG occlusion at 1 year, assessed with coronary computed tomography angiography, in all patients that had primary outcome imaging available. A generalized estimating equation model was used to perform the primary analysis per SVG. The secondary outcome was 1-year SVG failure, which was a composite of SVG occlusion, SVG revascularization, myocardial infarction in myocardial territory supplied by a SVG, or sudden death. RESULTS: Among 499 randomly assigned patients, the mean age was 67.9±8.3 years, 87.1% were male, the indication for CABG was acute coronary syndrome in 31.3%, and 95.2% of procedures used cardiopulmonary bypass. Primary outcome imaging was available in 220 patients in the ticagrelor group and 223 patients in the placebo group. The SVG occlusion rate in the ticagrelor group was 10.5% (51 of 484 SVGs) versus 9.1% in the placebo group (43 of 470 SVGs), odds ratio, 1.29 [95% CI, 0.73-2.30]; P=0.38. SVG failure occurred in 35 (14.2%) patients in the ticagrelor group versus 29 (11.6%) patients in the placebo group (odds ratio, 1.22 [95% CI, 0.72-2.05]). CONCLUSIONS: In this randomized, placebo-controlled trial, the addition of ticagrelor to standard aspirin did not reduce SVG occlusion at 1 year after CABG. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02352402.


Asunto(s)
Síndrome Coronario Agudo , Aspirina/administración & dosificación , Angiografía Coronaria , Puente de Arteria Coronaria , Oclusión de Injerto Vascular , Vena Safena/fisiopatología , Ticagrelor/administración & dosificación , Grado de Desobstrucción Vascular/efectos de los fármacos , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/fisiopatología , Síndrome Coronario Agudo/cirugía , Anciano , Aspirina/efectos adversos , Método Doble Ciego , Femenino , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/fisiopatología , Oclusión de Injerto Vascular/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Ticagrelor/efectos adversos
13.
N Engl J Med ; 383(15): 1447-1457, 2020 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-32865376

RESUMEN

BACKGROUND: The effect of single as compared with dual antiplatelet treatment on bleeding and thromboembolic events after transcatheter aortic-valve implantation (TAVI) in patients who do not have an indication for long-term anticoagulation has not been well studied. METHODS: In a randomized, controlled trial, we assigned a subgroup of patients who were undergoing TAVI and did not have an indication for long-term anticoagulation, in a 1:1 ratio, to receive aspirin alone or aspirin plus clopidogrel for 3 months. The two primary outcomes were all bleeding (including minor, major, and life-threatening or disabling bleeding) and non-procedure-related bleeding over a period of 12 months. Most bleeding at the TAVI puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2) at 1 year, with both outcomes tested sequentially for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: A total of 331 patients were assigned to receive aspirin alone and 334 were assigned to receive aspirin plus clopidogrel. A bleeding event occurred in 50 patients (15.1%) receiving aspirin alone and in 89 (26.6%) receiving aspirin plus clopidogrel (risk ratio, 0.57; 95% confidence interval [CI], 0.42 to 0.77; P = 0.001). Non-procedure-related bleeding occurred in 50 patients (15.1%) and 83 patients (24.9%), respectively (risk ratio, 0.61; 95% CI, 0.44 to 0.83; P = 0.005). A secondary composite 1 event occurred in 76 patients (23.0%) receiving aspirin alone and in 104 (31.1%) receiving aspirin plus clopidogrel (difference, -8.2 percentage points; 95% CI for noninferiority, -14.9 to -1.5; P<0.001; risk ratio, 0.74; 95% CI for superiority, 0.57 to 0.95; P = 0.04). A secondary composite 2 event occurred in 32 patients (9.7%) and 33 patients (9.9%), respectively (difference, -0.2 percentage points; 95% CI for noninferiority, -4.7 to 4.3; P = 0.004; risk ratio, 0.98; 95% CI for superiority, 0.62 to 1.55; P = 0.93). A total of 44 patients (13.3%) and 32 (9.6%), respectively, received oral anticoagulation during the trial. CONCLUSIONS: Among patients undergoing TAVI who did not have an indication for oral anticoagulation, the incidence of bleeding and the composite of bleeding or thromboembolic events at 1 year were significantly less frequent with aspirin than with aspirin plus clopidogrel administered for 3 months. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Asunto(s)
Aspirina/uso terapéutico , Clopidogrel/uso terapéutico , Hemorragia/inducido químicamente , Inhibidores de Agregación Plaquetaria/uso terapéutico , Trombosis/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Administración Oral , Anciano , Anciano de 80 o más Años , Aspirina/efectos adversos , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/mortalidad , Clopidogrel/efectos adversos , Quimioterapia Combinada , Femenino , Hemorragia/epidemiología , Humanos , Incidencia , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Periodo Posoperatorio , Trombosis/epidemiología
14.
Curr Cardiol Rep ; 22(9): 80, 2020 07 09.
Artículo en Inglés | MEDLINE | ID: mdl-32648007

RESUMEN

PURPOSE OF REVIEW: The TAVR procedure is a well-established therapy for patients with severe aortic stenosis at intermediate/high risk for surgery and a potential treatment for low-risk patients. It is much less invasive with short hospital stays and presents similar results compared with SAVR. Different "minimalist approach strategies" were proposed in order to obtain this performance. In these settings, transesophageal echocardiography (TEE) became less relevant for the TAVR procedure. The present review provides an update regarding the safety of TAVR without intraprocedural TEE. RECENT FINDINGS: Transthoracic echocardiography and fluoroscopy are the primary imaging tools during TAVR. Several studies proved that TAVR under local anesthesia without TEE is as safe as that performed under TEE guidance. However, not all patients have a proper window for TTE, and particular cases with complex anatomy can benefit from TEE support during the intervention. Intraprocedural TEE no longer plays a crucial role in the TAVR procedure, but in some instances, it remains of great help to detect and avoid complications.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Ecocardiografía Transesofágica , Humanos , Resultado del Tratamiento
15.
Expert Rev Med Devices ; 17(7): 615-626, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32543911

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) is associated with an increased risk of stroke. Stroke prevention with oral anticoagulation (OAC) is recommended in AF patients at increased risk of stroke. The left atrial appendage (LAA) is the main source of thrombus formation in AF patients. The WATCHMAN percutaneous LAA closure (LAAC) device may serve as an alternative to OAC overcoming disadvantages including the risk of (major) bleeding. AREAS COVERED: This review will focus on LAAC with the Watchman device for stroke prevention in AF patients. Current status, available literature, clinical safety and efficacy will be summarized. Furthermore, the future perspectives of Watchman will be discussed. EXPERT OPINION: LAAC with Watchman appears a promising, safe, and effective alternative to OAC. Ongoing and future studies to consolidate the position of Watchman should focus on comparative safety and efficacy of different LAAC devices, patient selection, various post-procedural antithrombotic regimens, head-to-head comparisons with NOAC, better understanding of device-related thrombus, and the role of the LAA in the propagation of non-valvular AF. This research may attribute to a paradigm shift in which LAAC no longer serves as a 'last resort' treatment for AF patients ineligible for OAC but may serve as a second-line or even first-line treatment option for AF patients.


Asunto(s)
Apéndice Atrial/patología , Fibrilación Atrial/terapia , Equipos y Suministros , Anticoagulantes/efectos adversos , Fibrilación Atrial/complicaciones , Análisis Costo-Beneficio , Equipos y Suministros/efectos adversos , Equipos y Suministros/economía , Humanos , Resultado del Tratamiento
16.
BMC Health Serv Res ; 20(1): 232, 2020 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-32192477

RESUMEN

BACKGROUND: Measuring and improving outcomes is a central element of value-based health care. However, selecting improvement interventions based on outcome measures is complex and tools to support the selection process are lacking. The goal was to present strategies for the systematic identification and selection of improvement interventions applied to the case of aortic valve disease and to combine various methods of process and outcome assessment into one integrated approach for quality improvement. METHODS: For this case study a concept-driven mixed-method approach was applied for the identification of improvement intervention clusters including: (1) benchmarking outcomes, (2) data exploration, (3) care delivery process analysis, and (4) monitoring of ongoing improvements. The main outcome measures were long-term survival and 30-day mortality. For the selection of an improvement intervention, the causal relations between the potential improvement interventions and outcome measures were quantified followed by a team selection based on consensus from a multidisciplinary team of professionals. RESULTS: The study resulted in a toolbox: the Intervention Selection Toolbox (IST). The toolbox comprises two phases: (a) identifying potential for improvement, and (b) selecting an effective intervention from the four clusters expected to lead to the desired improvement in outcomes. The improvements identified for the case of aortic valve disease with impact on long-term survival in the context of the studied hospital in 2015 include: anticoagulation policy, increased attention to nutritional status of patients and determining frailty of patients before the treatment decision. CONCLUSIONS: Identifying potential for improvement and carefully selecting improvement interventions based on (clinical) outcome data demands a multifaceted approach. Our toolbox integrates both care delivery process analyses and outcome analyses. The toolbox is recommended for use in hospital care for the selection of high-impact improvement interventions.


Asunto(s)
Atención a la Salud/normas , Cardiopatías Congénitas , Enfermedades de las Válvulas Cardíacas , Mejoramiento de la Calidad , Resultado del Tratamiento , Válvula Aórtica/fisiopatología , Benchmarking , Enfermedad de la Válvula Aórtica Bicúspide , Servicios de Salud , Cardiopatías Congénitas/mortalidad , Enfermedades de las Válvulas Cardíacas/mortalidad , Hospitales , Humanos , Evaluación de Resultado en la Atención de Salud
17.
N Engl J Med ; 382(18): 1696-1707, 2020 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-32223116

RESUMEN

BACKGROUND: The roles of anticoagulation alone or with an antiplatelet agent after transcatheter aortic-valve implantation (TAVI) have not been well studied. METHODS: We performed a randomized trial of clopidogrel in patients undergoing TAVI who were receiving oral anticoagulation for appropriate indications. Patients were assigned before TAVI in a 1:1 ratio not to receive clopidogrel or to receive clopidogrel for 3 months. The two primary outcomes were all bleeding and non-procedure-related bleeding over a period of 12 months. Procedure-related bleeding was defined as Bleeding Academic Research Consortium type 4 severe bleeding, and therefore most bleeding at the puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction at 12 months (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2), both tested for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: Bleeding occurred in 34 of the 157 patients (21.7%) receiving oral anticoagulation alone and in 54 of the 156 (34.6%) receiving oral anticoagulation plus clopidogrel (risk ratio, 0.63; 95% confidence interval [CI], 0.43 to 0.90; P = 0.01); most bleeding events were at the TAVI access site. Non-procedure-related bleeding occurred in 34 patients (21.7%) and in 53 (34.0%), respectively (risk ratio, 0.64; 95% CI, 0.44 to 0.92; P = 0.02). Most bleeding occurred in the first month and was minor. A secondary composite 1 event occurred in 49 patients (31.2%) receiving oral anticoagulation alone and in 71 (45.5%) receiving oral anticoagulation plus clopidogrel (difference, -14.3 percentage points; 95% CI for noninferiority, -25.0 to -3.6; risk ratio, 0.69; 95% CI for superiority, 0.51 to 0.92). A secondary composite 2 event occurred in 21 patients (13.4%) and in 27 (17.3%), respectively (difference, -3.9 percentage points; 95% CI for noninferiority, -11.9 to 4.0; risk ratio, 0.77; 95% CI for superiority, 0.46 to 1.31). CONCLUSIONS: In patients undergoing TAVI who were receiving oral anticoagulation, the incidence of serious bleeding over a period of 1 month or 1 year was lower with oral anticoagulation alone than with oral anticoagulation plus clopidogrel. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Asunto(s)
Anticoagulantes/uso terapéutico , Clopidogrel/uso terapéutico , Hemorragia/inducido químicamente , Inhibidores de Agregación Plaquetaria/uso terapéutico , Reemplazo de la Válvula Aórtica Transcatéter , Administración Oral , Anciano , Anciano de 80 o más Años , Anticoagulantes/efectos adversos , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/mortalidad , Clopidogrel/efectos adversos , Quimioterapia Combinada , Hemorragia/epidemiología , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
18.
Clin Res Cardiol ; 109(9): 1125-1139, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32006156

RESUMEN

BACKGROUND: The efficacy of antiplatelet therapies following percutaneous coronary intervention (PCI) may be affected by body mass index (BMI). METHODS AND RESULTS: This is a prespecified subgroup analysis of the GLOBAL LEADERS trial, a prospective, multicenter, open-label, randomized controlled trial in an all-comer population undergoing PCI, comparing the experimental strategy (23-month ticagrelor monotherapy following 1-month dual antiplatelet therapy [DAPT]) with a reference regimen (12-month aspirin monotherapy following 12-month DAPT). A total of 15,968 patients were stratified by baseline BMI with prespecified threshold of 27 kg/m2. Of those, 6973 (43.7%) patients with a BMI < 27 kg/m2 had a higher risk of all-cause mortality at 2 years than those with BMI ≥ 27 kg/m2 (adjusted HR 1.24, 95% CI 1.02-1.49). At 2 years, the rates of the primary endpoint (all-cause mortality or new Q-wave myocardial infarction) were similar between treatment strategies in either BMI group (pinteraction = 0.51). In acute coronary syndrome, however, the experimental strategy was associated with significant reduction of the primary endpoint compared to the reference strategy in patients with BMI < 27 kg/m2 (HR 0.69, 95% CI 0.51-0.94), but not in the ones with BMI ≥ 27 kg/m2 (pinteraction = 0.047). In chronic coronary syndrome, there was no between-group difference in the efficacy and safety of the two antiplatelet strategies. CONCLUSIONS: Overall, BMI did not influence the treatment effect seen with ticagrelor monotherapy; however, a beneficial effect of ticagrelor monotherapy was seen in ACS patients with BMI < 27 kg/m2. TRIAL REGISTRATION: The trial has been registered with ClinicalTrials.gov, Number NCT01813435.


Asunto(s)
Síndrome Coronario Agudo/terapia , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Anciano , Aspirina/administración & dosificación , Índice de Masa Corporal , Quimioterapia Combinada , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Estudios Prospectivos , Ticagrelor/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
19.
BMJ Open Qual ; 8(4): e000716, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31799447

RESUMEN

Background: As process measures can be means to change practices, this article presents process measures that impact on outcome measures for surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) within value-based healthcare. Methods: Desk research and observations of patient trajectories were performed to map the processes involved in TAVR and SAVR. Semistructured interviews were conducted with healthcare professionals (n=8) and patients (n=2) to explore which processes were most important in relation to a standard set of outcome measures that was already monitored. Additionally, open interviews (n=2) were held to prioritise results. A focus group was performed for validation of the formulated process measures. Numerical data for these measures was not collected. Results: Process maps of the full cycle of care of TAVR and SAVR treatments in theory and in practice were developed. 28 processes were found important by interview participants due to their expected impact on patient-relevant outcomes. Seven processes were prioritised to be most important and were formulated into 12 process measures for both TAVR and SAVR: 'Number of times that deficient information provision to SAVR patients causes negative outcomes', 'Type of TAVR/SAVR prosthesis', 'Brand of TAVR prosthesis', 'Number of times the frailty score of a TAVR/SAVR patient >75 years is measured', 'Time between TAVR/SAVR surgery indication and surgery', 'Number of times that anticoagulants are stopped within 3 days before surgery', 'Time in hours between TAVR/SAVR surgery and permanent pacemaker implantation' and 'Percentage of standardised pain measurements'. Conclusion: This study proposes an addition of select process measures to standard sets of outcome measures to improve healthcare quality. It illustrates a clear method for identifying process measures with impact on health outcomes in the future.


Asunto(s)
Válvula Aórtica/cirugía , Evaluación de Procesos, Atención de Salud/normas , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Grupos Focales , Humanos , Entrevistas como Asunto , Grupo de Atención al Paciente
20.
Front Cardiovasc Med ; 6: 146, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31681798

RESUMEN

Mitral valve disease affects more than 4 million people in the United States and it is the second most prevalent valvulopathy in Europe. The gold standard of treatment in these patients is surgical repair or mitral valve replacement. In the last decade, numerous transcatheter therapies have been developed to overcome the increased number of subjects with symptomatic severe mitral regurgitation and high surgical risk. The Mitraclip (Abbott Vascular, Menlo Park, CA), PASCAL (Edwards Lifesciences, Irvine, CA, USA), the Carillon™ Mitral Contour System™ (Cardiac Dimension Inc., Kirkland, WA, USA), the Mitralign™ (Mitralign, Tewksbury, Massachusetts), and the Cardioband (Edwards Lifesciences, Irvine, CA) are the principal percutaneous devices for mitral valve repair. We present an evidence-based clinical update that provides an overview of these technologies and their potential complications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA