Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Rheumatology (Oxford) ; 57(5): 865-872, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29471516

RESUMEN

Objective: To develop an optical spectral transmission (OST) model to measure joint inflammation, and thus disease activity, as well as to evaluate (patho-)physiological findings that could lead to misclassification of inflammation. Methods: Forty-six RA patients were included in this cross-sectional study, where US scores, duplicate OST measurements and 28-joint DAS (DAS28) were acquired. With US as a reference standard, the diagnostic performance of OST in detecting inflammation at the joint level was evaluated using receiver operating characteristic (ROC) curve analyses. At the patient level, correlations with US were analysed for DAS28 and OST, and at joint level for OST and tender and swollen joint counts (TJC and SJC, respectively). Joint pathology potentially influencing misclassification by OST [erosions, osteophytes, tendon (sheath) inflammation (ab)normal vasculature and chondrocalcinosis] was evaluated for significance in a multivariate nominal logistic regression model. Results: Diagnostic performance of OST was good for MCP [area under the ROC curve (AUC-ROC) 0.88], PIP (AUC-ROC 0.83) and wrist (AUC-ROC 0.74) joints and for all joints together (AUC-ROC 0.85). At the patient level, DAS28 correlated very poorly (ρ = 0.06) and OST moderately (ρ = 0.54) with US. At the joint level, US correlation with OST was strong (ρ = 0.64), with SJC it was weak (ρ = 0.30) and with TJC it was very weak (ρ = -0.02). Misclassification of inflammation by OST was relatively rare (17%). Dorsal erosions [odds ratio (OR) 4.0], osteophytes (OR 2.1) and extensor tendinitis (OR 4.6) increased the risk of underestimating inflammation of MCP and PIP joints and osteophytes (OR 3.0) also increased the risk of overestimating inflammation. Conclusion: OST is a sensitive, specific and objective technique to assess joints inflammation of the hands and wrists of RA patients, even though bone and tendon pathology increases the risk of misclassification.


Asunto(s)
Artritis Reumatoide/diagnóstico , Articulación del Codo/diagnóstico por imagen , Dispositivos Ópticos , Articulación del Hombro/diagnóstico por imagen , Ultrasonografía Doppler/métodos , Articulación de la Muñeca/diagnóstico por imagen , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Índice de Severidad de la Enfermedad
2.
J Biomed Opt ; 17(8): 081420, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23224181

RESUMEN

Frequent monitoring of rheumatoid arthritis (RA) patients enables timely treatment adjustments and improved outcomes. Currently this is not feasible due to a shortage of rheumatologists. An optical spectral transmission device is presented for objective assessment of joint inflammation in RA patients, while improving diagnostic accuracy and clinical workflow. A cross-sectional, nonrandomized observational study was performed with this device. In the study, 77 proximal interphalangeal (PIP) joints in 67 patients have been analyzed. Inflammation of these PIP joints was also assessed by a rheumatologist with a score varying from 1 (not inflamed) to 5 (severely inflamed). Out of 77 measurements, 27 were performed in moderate to strongly inflamed PIP joints. Comparison between the clinical assessment and an optical measurement showed a correlation coefficient r=0.63, p<0.001, 95% CI [0.47, 0.75], and a ROC curve (AUC=0.88) that shows a relative good specificity and sensitivity. Optical spectral transmission measurements in a single joint correlate with clinical assessment of joint inflammation, and therefore might be useful in monitoring joint inflammation in RA patients.


Asunto(s)
Artritis Reumatoide/diagnóstico , Artritis Reumatoide/fisiopatología , Diagnóstico por Computador/métodos , Articulaciones de los Dedos/fisiopatología , Nefelometría y Turbidimetría/métodos , Análisis Espectral/métodos , Estudios de Factibilidad , Femenino , Humanos , Articulaciones , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA