Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ultrason Sonochem ; 76: 105651, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34242866

RESUMEN

Traditional cell/particle isolation methods are time-consuming and expensive and can lead to morphology disruptions due to high induced shear stress. To address these problems, novel lab-on-a-chip-based purification methods have been employed. Among various methods introduced for the separation and purification of cells and synthetics particles, acoustofluidics has been one of the most effective methods. Unlike traditional separation techniques carried out in clinical laboratories based on chemical properties, the acoustofluidic process relies on the physical properties of the sample. Using acoustofluidics, manipulating cells and particles can be achieved in a label-free, contact-free, and highly biocompatible manner. To optimize the functionality of the platform, the numerical study should be taken into account before conducting experimental tests to save time and reduce fabrication expenses. Most current numerical studies have only considered one-dimensional harmonic standing waves to simulate the acoustic pressure distribution. However, one-dimensional simulations cannot calculate the actual acoustic pressure distribution inside the microchannel due to its limitation in considering longitudinal waves. To address this limitation, a two-dimensional numerical simulation was conducted in this study. Our numerical simulation investigates the effects of the platform geometrical and operational conditions on the separation efficiency. Next, the optimal values are tested in an experimental setting to validate these optimal parameters and conditions. This work provides a guideline for future acoustofluidic chip designs with a high degree of reproducibility and efficiency.

2.
Sci Rep ; 10(1): 11718, 2020 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-32678180

RESUMEN

Advances in lab-on-a-chip (LOC) devices have led to significant improvements in the on-chip manipulation, separation, sorting, and isolation of particles and cells. Among various LOC-based approaches such as inertia-based methods, acoustophoresis, and magnetophoresis, the planar-slanted-electrode dielectrophoresis (DEP) method has demonstrated great potential as a label-free, cost-effective, and user-friendly approach. However, the devices built based on this method suffer from low flow throughput compared to devices functioning based on other LOC-based manipulation approaches. In order to overcome this obstacle, the geometrical parameters of these types of DEP-based devices must be studied to increase the effectiveness of DEP manipulation. With the consideration of both numerical and experimental studies, this paper studies the geometrical factors of a LOC platform consisting of tilted planar electrodes with the goal of achieving higher throughput in continuous manipulation of polystyrene particles. COMSOL Multiphysics software was used to study the effect of the electrodes geometry on the induced electric field. The simulation results show that by increasing the electrode's width and decreasing the electrode's spacing, higher DEP force is generated. Furthermore, the experimental outcomes indicated that lower channel height, higher voltage, and larger particle size resulted in the most improvement to DEP manipulation. Additionally, the experimental results demonstrated that slanted electrodes with an angle of 8° with respect to the direction of flow provide a more effective configuration.

3.
Mater Horiz ; 5(5): 813-822, 2018 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39119486

RESUMEN

Nature generates densely packed micro- and nanostructures to enable key functionalities in cells, tissues, and other materials. Current fabrication techniques, due to limitations in resolution and speed, are far less effective at creating microstructures. Yet, the development of extensive amounts of surface area per unit volume will enable applications and manufacturing strategies not possible today. Here, we introduce chaotic printing-the use of chaotic flows for the rapid generation of complex, high-resolution microstructures. A simple and deterministic chaotic flow is induced in a viscous liquid, and its repeated stretching and folding action deforms an "ink" (i.e., a drop of a miscible liquid, fluorescent beads, or cells) at an exponential rate to render a densely packed lamellar microstructure that is then preserved by curing or photocrosslinking. This exponentially fast creation of fine microstructures exceeds the limits of resolution and speed of the currently available 3D printing techniques. Moreover, we show that the architecture of the microstructure to be created with chaotic printing can be predicted by mathematical modelling. We envision diverse applications for this technology, including the development of densely packed catalytic surfaces and highly complex multi-lamellar and multi-component tissue-like structures for biomedical and electronics applications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA