Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Chromatogr A ; 1101(1-2): 254-60, 2006 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-16246351

RESUMEN

A study attempted to characterize natural waxes used in pictorial works of art was carried out by means of gas chromatography. The analytical treatment requires prior hydrolysis of the waxes to release the fatty acids (FA) (myristic (myr), palmitic (pal), oleic (ole), stearic (ste), araquidic (ara), behenic (beh), lignoceric (lig), cerotic (cer)) from the main esters of the waxes. The formation of volatile derivatives of the fatty acids was carried out by derivatization with ethyl choroformate (ECF). This derivatization reagent was chosen due to the speed, safety and quantitativity of the reaction. The analyzed hydrocarbons were n-eicosane, n-heneicosane, n-docosane, n-tricosane, n-tetracosane, n-pentacosane, n-hexacosane, n-heptacosane, n-octacosane, n-nonacosane, n-tricontane n-hentriacontane, n-dotriacontane, n-tritriacontane, n-tetratriacontane, n-pentatriacontane, main constituents of the waxes. No derivatization is needed to analyze the hydrocarbons. Ethyl ester derivatives and hydrocarbons are adequately separated by gas chromatography, identified by flame ionization detection and confirmed by mass spectrometry. To characterize natural waxes, peak area ratios of each fatty acids with respect to the palmitic acid and peak area ratios of each hydrocarbons with respect to n-heptacosane were calculated. The proposed method provides a good characterization of different waxes most frequently used in artworks, such as beeswax, carnauba wax and ceresin, and has been successfully applied to real samples. This is the first report on the application of ECF to the analysis of fatty acids in wax.


Asunto(s)
Cromatografía de Gases/métodos , Ácidos Grasos/análisis , Hidrocarburos/análisis , Pinturas , Ceras/química
2.
Talanta ; 68(5): 1648-54, 2006 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-18970510

RESUMEN

A HPLC-fluorescence method for characterization of proteinaceous glues from binding media used in pictorial works of art prior to conservation or restoration treatment is proposed. Fluorescence derivatization of amino acids released by acid hydrolysis of standard proteins is studied. The derivatization reagent was o-phtalaldehyde with 2-mercaptoethanol as catalyst. Mobile phase was a programmed gradient among two eluents (water buffered at pH 5.8 wit 5% THF, and methanol) and is able to satisfactorily resolve the amino acid derivatives in 45min. Peak area ratios among amino acid derivatives and the leucine derivative are useful to characterize the proteins. The method shows good sensitivity and adequate linearity between 2.0x10(-3) and 3.3mmol/l of each amino acid, with a limit of detection of 6.0x10(-4)mmol/l. The proposed method has been successfully applied to artistic samples from items of the cultural heritage of Valencia (Spain).

3.
Talanta ; 58(4): 811-21, 2002 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-18968811

RESUMEN

A methodology for quantifying calcium carbonate (875 and 712 cm(-1)) and silica (798 and 779 cm(-1)) by FTIR spectroscopy applying the constant ratio method is proposed. The studied method is applied for quantitative analysis of calcite and quartz in geological samples. The suggested method uses potassium ferricyanide (2115 cm(-1)) as standard and samples are prepared as potassium bromide pellets, with statistically satisfactory results (relative standard deviation less than 5%). The influence of particle size (pulverised samples) on the accuracy of the results found by FTIR spectroscopy applying the constant ratio method has been studied. The granulometric study suggests that the homogeneity of particle size is important. An absorbances correction method is proposed to correct spectral interferences. Due to the fact that most spectra are characterised by a high number of absorbance peaks, spectral interferences may occur so that some peaks cannot be used for quantitative analysis. These interferences can be evaluated and eliminated with the proposed method and the peaks can be used in the analysis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA