Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biomed Res Int ; 2020: 3432987, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33145346

RESUMEN

INTRODUCTION: Literature shows platelet-rich plasma (PRP) to improve overall outcomes in orthopedics, dermatology, ophthalmology, gynecology, and plastic surgery. Data on oncological patients is very limited. Only one publication is available on PRP in breast cancer patients. This work evaluated PRP in sentinel node biopsy procedures for breast cancer patients in terms of complication rates and oncological short-term follow-up. METHODS: The evaluated PRP was ACP®, i.e., autologous conditioned plasma by Arthrex®. Between 2015 and 2018, 163 patients were offered to receive an ACP®/PRP injection in their lymph node biopsy site. Recruitment resulted in an approximate one-to-one ratio for analysis. Endpoints were major (revision) and minor (seroma, hematoma, and infection) complications rates as well as distant metastases, local recurrence, and overall survival. Median follow-up was 30 months. RESULTS: Complication rates and oncological follow-up showed PRP to be applicable to use in a sentinel node biopsy scenario in breast cancer patients. There were 0 revisions in the ACP®/PRP group and 1.2% revisions in the control group (not significant). Oncological follow-up showed zero (0) distant metastases and local recurrences as well as a 100% 30-month overall survival. CONCLUSIONS: This is the first analysis of ACP®/PRP used in breast cancer patients in a sentinel node biopsy setting worldwide. PRP does not seem to increase rates of local recurrence within this 30-month follow-up time frame. Also, trend towards decreasing complication rates could be shown.


Asunto(s)
Neoplasias de la Mama/cirugía , Escisión del Ganglio Linfático/métodos , Recurrencia Local de Neoplasia/prevención & control , Plasma Rico en Plaquetas/fisiología , Ganglio Linfático Centinela/cirugía , Adulto , Anciano , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/mortalidad , Neoplasias de la Mama/patología , Femenino , Humanos , Metástasis Linfática/prevención & control , Persona de Mediana Edad , Ganglio Linfático Centinela/patología , Biopsia del Ganglio Linfático Centinela , Análisis de Supervivencia
2.
Arch Gynecol Obstet ; 299(5): 1337-1343, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30905000

RESUMEN

INTRODUCTION: Pectopexy, a laparoscopic method for prolapse surgery, showed promising results in previous transient testing by this group. It was shown that a single suture, yielding an ultimate load of 35 N, was equivalent to continuous suturing. This was demonstrated in an in vitro cadaver study. This transient data were used to establish an elastic stress-strain envelope. It was now possible to proceed to dynamic in vitro analysis of this surgical method to establish time to functional stability. METHODS: Cyclic testing of this fixation method was performed on human female embalmed cadaver (cohort 1) and fresh, non-embalmed cadaver (cohort 2) pelvises. The testing envelope was 5-25 N at a speed of 1 mm/s. 100 load regulated cycles were applied. RESULTS: 100 cycles were completed with each model; no overall system failure occurred. Steady state, i.e., functional stability was reached after 14.5 (± 2.9) cycles for the embalmed group and after 19.1 (± 7.2) cycles for the non-embalmed group. This difference was statistically significant p = 0.00025. CONCLUSION: This trial showed in an in vitro cyclic testing of the pectopexy method that functional stability may be achieved after no more than 19.1 cycles of load exposure. When remaining within the established load envelope of below 25 N, patients do not need to fear global fixation failure. Testing did demonstrate differences in non-embalmed and embalmed cadaver testing. Embalmed cadaver testing tends to underestimate time to steady state by 26.3%.


Asunto(s)
Laparoscopía/métodos , Prolapso de Órgano Pélvico/cirugía , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cadáver , Femenino , Estudios de Seguimiento , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA