Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Intervalo de año de publicación
1.
Codas ; 36(4): e20230149, 2024.
Artículo en Portugués, Inglés | MEDLINE | ID: mdl-38836829

RESUMEN

PURPOSE: To propose a methodology for analyzing data generated by an instrument measuring non-nutritive sucking pressure in newborns. METHODS: An analytical observational study was developed, with a cross-sectional design, considering the data collected from 24 full-term newborns without complications. Three collections from each neonate were analyzed, with duration of 2 minutes and a 2-minute interval between them. The defined parameters were extracted using a program developed in Matlab®. The results were obtained by analyzing and comparing 12 variables at a 5% confidence level. Comparison of manual and computerized analyzes was also carried out using the intraclass correlation coefficient. RESULTS: The multiple comparison between the three collection moments showed that the significant statistical differences occurred between collections one and two and two and three. When analyzing and comparing each variable separately, it was noted that the second collection showed: greater number of sucking groups, greater number of suctions, less time to start the sucking groups, longer time of sucking groups, less number of sporadic suctions, higher mean pressure values and with less standard deviation, more number of pauses with shorter time of pauses. The intraclass correlation coefficient revealed almost perfect agreement for the 12 evaluated parameters. CONCLUSION: The 12 variables analyzed are relevant, especially in the second collection. The Matlab® program proved to be viable and effective in extracting and analyzing parameters, showing high agreement when compared to manual evaluation.


OBJETIVO: Propor uma metodologia de análise dos dados gerados por um instrumento de medição da pressão de sucção não-nutritiva do recém-nascido. MÉTODO: Estudo observacional analítico, transversal com dados de 24 recém-nascidos a termo sem comprometimentos. Após a avaliação clínica foram analisadas três coletas de cada neonato empregando-se o referido instrumento, com duração de 2 minutos e intervalo de 2 minutos entre elas. Os parâmetros definidos foram extraídos por meio de um programa desenvolvido em Matlab®. Os resultados foram obtidos pela análise e comparação de 12 variáveis ao nível de confiança de 5%. Foi realizada ainda comparação das análises manual e computadorizada por meio do coeficiente de correlação intraclasse. RESULTADOS: A comparação múltipla entre os três momentos de coleta, mostrou que as diferenças estatísticas significantes ocorreram entre as coletas um e dois e dois e três. Ao se analisar e comparar cada variável separadamente, notou-se que a segunda coleta apresentou: maior número de grupos de sucção, maior número de sucções, menor tempo para iniciar os grupos de sucção, maior tempo de grupos de sucção, menor número de sucções esporádicas, valores de pressão média maiores e com menor desvio padrão, maior número de pausas com tempo de pausas menor. O coeficiente de correlação intraclasse revelou concordância quase perfeita para os 12 parâmetros avaliados. CONCLUSÃO: As 12 variáveis analisadas mostram-se relevantes, especialmente na segunda coleta. O programa em Matlab® mostrou-se viável e eficaz na extração e análise dos parâmetros, apresentando alta concordância quando comparado à avaliação manual.


Asunto(s)
Conducta en la Lactancia , Humanos , Recién Nacido , Estudios Transversales , Conducta en la Lactancia/fisiología , Factores de Tiempo , Femenino , Masculino
2.
CoDAS ; 36(4): e20230149, 2024. tab, graf
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1557622

RESUMEN

RESUMO Objetivo Propor uma metodologia de análise dos dados gerados por um instrumento de medição da pressão de sucção não-nutritiva do recém-nascido. Método Estudo observacional analítico, transversal com dados de 24 recém-nascidos a termo sem comprometimentos. Após a avaliação clínica foram analisadas três coletas de cada neonato empregando-se o referido instrumento, com duração de 2 minutos e intervalo de 2 minutos entre elas. Os parâmetros definidos foram extraídos por meio de um programa desenvolvido em Matlab®. Os resultados foram obtidos pela análise e comparação de 12 variáveis ao nível de confiança de 5%. Foi realizada ainda comparação das análises manual e computadorizada por meio do coeficiente de correlação intraclasse. Resultados A comparação múltipla entre os três momentos de coleta, mostrou que as diferenças estatísticas significantes ocorreram entre as coletas um e dois e dois e três. Ao se analisar e comparar cada variável separadamente, notou-se que a segunda coleta apresentou: maior número de grupos de sucção, maior número de sucções, menor tempo para iniciar os grupos de sucção, maior tempo de grupos de sucção, menor número de sucções esporádicas, valores de pressão média maiores e com menor desvio padrão, maior número de pausas com tempo de pausas menor. O coeficiente de correlação intraclasse revelou concordância quase perfeita para os 12 parâmetros avaliados. Conclusão As 12 variáveis analisadas mostram-se relevantes, especialmente na segunda coleta. O programa em Matlab® mostrou-se viável e eficaz na extração e análise dos parâmetros, apresentando alta concordância quando comparado à avaliação manual.


ABSTRACT Purpose To propose a methodology for analyzing data generated by an instrument measuring non-nutritive sucking pressure in newborns. Methods An analytical observational study was developed, with a cross-sectional design, considering the data collected from 24 full-term newborns without complications. Three collections from each neonate were analyzed, with duration of 2 minutes and a 2-minute interval between them. The defined parameters were extracted using a program developed in Matlab®. The results were obtained by analyzing and comparing 12 variables at a 5% confidence level. Comparison of manual and computerized analyzes was also carried out using the intraclass correlation coefficient. Results The multiple comparison between the three collection moments showed that the significant statistical differences occurred between collections one and two and two and three. When analyzing and comparing each variable separately, it was noted that the second collection showed: greater number of sucking groups, greater number of suctions, less time to start the sucking groups, longer time of sucking groups, less number of sporadic suctions, higher mean pressure values and with less standard deviation, more number of pauses with shorter time of pauses. The intraclass correlation coefficient revealed almost perfect agreement for the 12 evaluated parameters. Conclusion The 12 variables analyzed are relevant, especially in the second collection. The Matlab® program proved to be viable and effective in extracting and analyzing parameters, showing high agreement when compared to manual evaluation.

3.
Rev. Soc. Bras. Fonoaudiol ; 15(3): 383-389, 2010. tab
Artículo en Portugués | LILACS | ID: lil-566368

RESUMEN

OBJETIVO: Investigar a existência de alterações na audição de crianças com fenilcetonúria diagnosticadas e tratadas precocemente e comparar os resultados com os encontrados nas avaliações auditivas de crianças normais de mesma idade. MÉTODOS: Foram realizadas imitanciometria e audiometria tonal e vocal em 63 crianças, sendo 30 no grupo controle, com média de idade de 8,1 anos, e 33 com fenilcetonúria no grupo de estudo, com média de idade de 7,7 anos. O grupo de estudo foi subdividido em 15 crianças com controle adequado da dieta e 18 crianças com controle inadequado da dieta, com médias de idade 8,1 e 7,2, respectivamente. A análise estatística utilizou o Teste t ou ANOVA. RESULTADOS: A audiometria revelou 83,3 por cento de crianças com audição normal no grupo controle e 16,7 por cento de perdas auditivas condutivas uni ou bilaterais. No grupo com fenilcetonúria, 66,7 por cento das crianças apresentaram audição normal e 33,3 por cento com perdas auditivas condutivas. Na imitanciometria, observou-se curvas normais em 91,7 por cento das crianças do grupo controle e em 72,7 por cento das crianças do grupo com fenilcetonúria. Houve diferença na comparação entre grupos para limiares aéreos, reflexos estapedianos, limiares de recepção da fala e índice de reconhecimento de fala. Não foi observada diferença entre os resultados das avaliações auditivas de crianças fenilcetonúricas com dieta adequada e inadequada. CONCLUSÃO: As crianças com fenilcetonúria diagnosticadas e tratadas precocemente apresentaram piores limiares de audibilidade por via aérea, limiares de recepção de fala e índice de reconhecimento de fala evidenciados à audiometria tonal e vocal, quando comparadas com crianças normais.


PURPOSE: To investigate the existence of hearing impairments in infants with phenylketonuria with early diagnose and treatment, and to compare the audiological findings with those of their normal peers. METHODS: Vocal and pure-tone audiometry and acoustic immitance tests were conducted in 63 children, 30 from a control group, with mean age of 8.1 years, and 33 from a study group, with phenylketonuria and mean age of 7.7 years. The study group was subdivided according to diet control: 15 subjects had adequate (mean age of 8.1 years) and 18 had inadequate diet control (mean age 7.2 years). Statistical analysis used t-test or ANOVA. RESULTS: Audiometry showed that, in the control group, 83.3 percent of the subjects had normal hearing, and 16.7 percent had uni- or bilateral conductive hearing loss. In the study group, 66.7 percent of the subjects presented normal hearing, and 33.3 percent had conductive hearing loss. Immitance measures showed normal results in 91.7 percent of the children from the control group, and in 72.7 percent of the subjects with phenylketonuria. Differences were found between the groups regarding hearing thresholds, acoustic reflexes, speech reception thresholds, and speech recognition. No differences were observed between the results of phenylketonuria subjects with adequate and inadequate diets. CONCLUSION: Children with phenylketonuria early diagnosed and treated presented worse conductive hearing thresholds, speech reception threshold and speech recognition when compared to their normal peers, as evidenced in pure-tone and vocal audiometry.


Asunto(s)
Humanos , Niño , Pruebas de Impedancia Acústica , Audiometría , Audición , Trastornos de la Audición , Pérdida Auditiva , Fenilcetonurias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA