Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Anaesthesia ; 65(7): 674-8, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20497150

RESUMEN

SUMMARY: Tracheal intubation using direct laryngoscopy has a high failure rate when performed by untrained medical personnel. This study compares tracheal intubation following direct laryngoscopy by inexperienced medical students when initially trained by using either the GlideScope, a video assisted laryngoscope, or a rigid (Macintosh) laryngoscope. Forty-two medical students with no previous experience in tracheal intubation were randomly divided into two equal groups to receive training with the GlideScope or with direct laryngoscopy. Subsequently, each medical student performed three consecutive intubations on patients with normal airways that were observed by a anaesthetist who was blinded to the training method. The rates of successful intubation were significantly higher in the Glidescope group after the first (48%), second (62%), and third (81%) intubations compared with the Macintosh group (14%, 14% and 33%; p = 0.043, 0.004 and 0.004, respectively). The mean (SD) times for the first, second, and third successful tracheal intubations were significantly shorter in the Glidescope group (59.3 (4.4) s, 56.6 (7.1) s and 50.1 (4.0) s) than the Macintosh group (70.7 (7.5) s, 73.7 (7.3) s and 67.6 (2.0) s; p = 0.006, 0.003 and 0.0001, respectively). Training with a video-assisted device such as the GlideScope improves the success rate and time for tracheal intubation in patients with normal airways when this is performed by inexperienced individuals following a short training programme.


Asunto(s)
Anestesiología/educación , Educación de Postgrado en Medicina/métodos , Intubación Intratraqueal/instrumentación , Laringoscopios , Adulto , Anciano , Competencia Clínica , Diseño de Equipo , Femenino , Humanos , Laringoscopía/métodos , Masculino , Persona de Mediana Edad , Método Simple Ciego , Factores de Tiempo , Grabación en Video
2.
J Laryngol Otol ; 122(8): 829-35, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17617935

RESUMEN

OBJECTIVE AND HYPOTHESIS: (1) To examine the vocal symptoms and acoustic changes perceived in the short period immediately after laryngeal mask airway, and (2) to compare these findings in patients using laryngeal mask airway and endotracheal tube. MATERIALS AND METHODS: A total of 27 patients were enrolled. They were evaluated pre-operatively and then at 2 and 24 hours post-operatively. Patients were divided into two subgroups, laryngeal mask airway and endotracheal tube. Patients were asked about the presence or absence of the following: hoarseness, vocal fatigue, loss of voice, throat-clearing sensation, globus pharyngeus and throat pain. Patients then underwent acoustic analysis of their voice, measuring the average fundamental frequency, relative average perturbation, shimmer, noise to harmony ratio, voice turbulence index, habitual pitch and maximum phonation time. RESULTS: In the laryngeal mask airway group, there was an increase in the incidence of all vocal symptoms two hours post-operatively, except for globus pharyngeus. The increase was statistically significant for vocal fatigue, loss of voice and throat pain. All the symptoms had reverted back to a normal baseline level by 24 hours. There was a decrease in the maximum phonation time and habitual pitch, with an increase in all the perturbation parameters, two hours post-operatively. At 24 hours, an increase was still present for shimmer, noise to harmony ratio and voice turbulence index. The maximum phonation time and habitual pitch reverted back to normal values. In the endotracheal tube group, there was a significant increase two hours post-operatively in the incidence of hoarseness, loss of voice and throat pain. At 24 hours, all the symptoms reverted to baseline, except for vocal fatigue and throat pain. Two hours post-operatively, there was a significant decrease in maximum phonation time and an increase in all other parameters (however, the latter was significant only for relative average perturbation and noise to harmony ratio). At 24 hours, there was a significant increase in the maximum phonation time and a persistent (but statistically insignificant) increase in the average fundamental frequency, habitual pitch, noise to harmony ratio and voice turbulence index. At two hours, there was more loss of voice and vocal fatigue in the laryngeal mask airway group, compared with the endotracheal tube group. At 24 hours, these symptoms were comparable in both groups. Comparing changes in acoustic parameters to baseline values in both groups, there were no statistically significant changes. CONCLUSION: Shortly after reversal of anaesthesia, laryngeal symptoms following laryngeal mask airway are no less significant than those experienced following endotracheal tube anaesthesia. Both methods can be regarded as nontraumatic, in view of the lack of significant vocal symptoms and acoustic changes 24 hours after anaesthesia.


Asunto(s)
Anestesia por Inhalación/métodos , Intubación Intratraqueal/efectos adversos , Máscaras Laríngeas/efectos adversos , Trastornos de la Voz/etiología , Acústica , Adolescente , Adulto , Anestesia por Inhalación/instrumentación , Distribución de Chi-Cuadrado , Femenino , Ronquera/etiología , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Prospectivos , Estadísticas no Paramétricas , Calidad de la Voz
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA