1.
BMJ Qual Saf ; 22(2): 124-9, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23112286

RESUMEN

OBJECTIVE: To compare a novel neonatal resuscitation cart (NRC) to a generic code cart (GCC). STUDY DESIGN: A prospective, randomised, controlled, crossover trial was performed to compare the utility of the NRC with the GCC during simulated deliveries of extremely low birthweight infants and infants with gastroschisis. Fifteen subjects participated. Mean times and accuracy of equipment and supply retrieval were compared for each scenario using the Wilcoxon test. RESULTS: Mean acquisition times for the NRC were always faster (by 58% to 74%) regardless of scenario (p<0.01). Accuracy of equipment selection did not differ. Ease of use was judged using a Likert scale (1=easiest to use; 5=most difficult), with mean score for NRC 1.1 and GCC 3.7 (p<0.0001). All subjects rated the NRC as easier to use. CONCLUSIONS: The NRC was superior to the GCC in acquisition speed, supply selection and ease of use.


Asunto(s)
Equipos y Suministros de Hospitales/normas , Unidades de Cuidado Intensivo Neonatal , Simulación de Paciente , Pediatría/instrumentación , Resucitación/estadística & datos numéricos , Obstrucción de las Vías Aéreas/terapia , Estudios Cruzados , Medicina Basada en la Evidencia , Gastrosquisis/complicaciones , Gastrosquisis/diagnóstico , Gastrosquisis/terapia , Humanos , Recien Nacido con Peso al Nacer Extremadamente Bajo , Recién Nacido , Enfermedades del Prematuro/terapia , Habitaciones de Pacientes , Ejecutivos Médicos/psicología , Estudios Prospectivos , Puerto Rico , Resucitación/métodos , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA