Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Bone Joint Surg Am ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38739702

RESUMEN

BACKGROUND: The objective of this study was to evaluate the correlation in measurements of the lower-limb coronal alignment between long-leg radiographs (LLRs) and computed tomography (CT) scanograms that were made during preoperative planning for robotic-arm-assisted knee arthroplasty. On the basis of published evidence demonstrating a good correlation between these imaging modalities in measuring the lower-limb mechanical axis, we hypothesized that there would be no significant differences between the 2 in the present study. METHODS: This multicenter cohort study across 3 tertiary centers included 300 patients undergoing primary robotic-arm-assisted total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA) for whom LLRs and CT scanograms were available preoperatively. The study involved measuring the medial proximal tibial angle (MPTA), lateral distal femoral angle (LDFA), hip-knee-ankle angle (HKA), joint line obliquity (JLO), joint-line convergence angle (JLCA), and arithmetic HKA (aHKA). The aHKA represents a method for estimating constitutional alignment using angles that are unaffected by joint-space narrowing. RESULTS: Strong correlations (p < 0.001) between the imaging modalities were found for the HKA (correlation coefficient, 0.912), aHKA (0.883), MPTA (0.820), LDFA (0.871), and JLO (0.778). A weaker correlation was observed for the JLCA in valgus knees as compared with varus knees (Spearman coefficients, 0.412 and 0.518, respectively). Regression models demonstrated that the degree of agreement was associated with the preoperative intra-articular deformity and the positioning of the lower limb during the CT scan (i.e., the lower-limb rotational angle). An initial JLCA within ±5° was associated with higher agreement. CONCLUSIONS: We observed a strong correlation between LLRs and CT scanograms that were made during the preoperative planning stage of robotic-arm-assisted knee arthroplasty, implying that CT scanograms can reliably be utilized to estimate the coronal alignment of the knee, potentially replacing the need for LLRs. Nevertheless, to attain a higher degree of agreement, it is crucial to ensure appropriate radiographic positioning of the lower limb. Additionally, surgeons must remain vigilant regarding potential discrepancies in cases involving substantial deformities. LEVEL OF EVIDENCE: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

2.
Int Orthop ; 47(2): 573-584, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36496548

RESUMEN

INTRODUCTION: Accurate implant positioning, tailored to the phenotype and unique biomechanics of each patient is the single most important objective in achieving stability in THA and maximise range of motion. The spine-pelvis-hip construct functions as a single unit adapting to postural changes. It is widely accepted in the literature that no universaltarget exists and variations in spinopelvic mobility mandate adjustments to the surgical plan; thus bringing to the fore the concept of personalised, functional component positioning. METHODS: This manuscript aims to outline the challenges posed by spinopelvic imbalance and present a reproducible, stepwise approach to achieve functional-component positioning. We also present the one-year functional outcomes and Patient Reported Outcome Measures of a prospective cohort operated with this technique. RESULTS AND CONCLUSION: Robotic-arm assisted Total Hip Arthroplasty has facilitated enhanced planning based on the patient's phenotype and evidence suggests it results in more reproducible and accurate implant positioning. Preservation of offset, avoiding leg-length discrepancy, accurate restoration of the centre of rotation and accomplishing the combinedversion target are very important parameters in Total Hip Arthroplasty that affect post-operative implant longevity, patient satisfaction and clinical outcomes.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios Prospectivos , Satisfacción del Paciente , Pelvis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA