Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Risk Uncertain ; 53(2): 107-136, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28405057

RESUMEN

The question of how to measure and classify people's risk preferences is of substantial importance in the field of economics. Inspired by the multitude of ways used to elicit risk preferences, we conduct a holistic investigation of the most prevalent method, the multiple price list (MPL) and its derivations. In our experiment, we find that revealed preferences differ under various versions of MPLs as well as yield unstable results within a 30-minute time frame. We determine the most stable elicitation method with the highest forecast accuracy by using multiple measures of within-method consistency and by using behavior in two economically relevant games as benchmarks. A derivation of the well-known method by Holt and Laury (American Economic Review 92(5):1644-1655, 2002), where the highest payoff is varied instead of probabilities, emerges as the best MPL method in both dimensions. As we pinpoint each MPL characteristic's effect on the revealed preference and its consistency, our results have implications for preference elicitation procedures in general.

2.
Int J Neuropsychopharmacol ; 10(2): 211-8, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16487452

RESUMEN

[123I]ADAM (2-((2-((dimethylamino)methyl)phenyl)thio)-5-iodophenylamine) is a promising radioligand for in-vivo quantification of serotonin transporters (SERT) using single photon emission computed tomography (SPECT) in man. We performed tracer kinetic analysis in various brain regions to determine the optimum equilibrium time for SERT quantification with [123I]ADAM and SPECT. Radiosyntheses of [123I]ADAM were performed at MAP Medical Technologies Oy, Tikkakoski, Finland. Thirty healthy male volunteers (21-41 yr) received between 104 and 163 MBq [123I]ADAM intravenously as a bolus. Consecutively, multiple SPECT scans were performed between 14 and 420 min post-injection (p.i.) using a Siemens Multispect 3 camera. Reconstruction was performed applying filtered back projection with a Butterworth filter (cut-off 0.7, order 7) in 128x128 matrices. Regions of interest (ROI) were drawn manually on the individual T1-weighted magnetic resonance image (MRI) comprising midbrain/hypothalamus for specific binding to SERT, and the cerebellum as reference region. After re-orientation to the MRI, the ROI template was applied to SPECT studies. We generated time-activity curves for the ROI and calculated the ratio countstarget/countscerebellum minus 1 (=V3'') as a measure for specific SERT binding. Counts were corrected for applied activity, acquisition time and body-weight. Peak uptakes were observed between 14 and 50 min after bolus injection. Counts per voxel were highest in the midbrain/hypothalamus, 798 (max. 872, min. 728), whereas 462 counts per voxel (max. 599, min. 412) were measured in the cerebellum at a mean time of 31 min p.i. Stable values for V3'' reached 205-320 min p.i. Mean peak V3'' value was 1.43 (95% CI 171-230) for the midbrain/hypothalamus at 205 min p.i. [123I]ADAM is a useful ligand for in-vivo quantification of human SERT by means of SPECT, with a comparatively better signal-to-noise ratio compared to beta-CIT. Our data suggest that the acquisition time for the SPECT scan is optimally, under pseudo-equilibrium conditions, between 205-320 min post-bolus injection of the tracer.


Asunto(s)
Cinanserina/análogos & derivados , Radiofármacos/farmacocinética , Proteínas de Transporte de Serotonina en la Membrana Plasmática/metabolismo , Adulto , Encéfalo/anatomía & histología , Encéfalo/diagnóstico por imagen , Cinanserina/farmacocinética , Humanos , Hipotálamo/anatomía & histología , Hipotálamo/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Mesencéfalo/anatomía & histología , Mesencéfalo/diagnóstico por imagen , Unión Proteica , Reproducibilidad de los Resultados , Tomografía Computarizada de Emisión de Fotón Único
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA