Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Plant Biol (Stuttg) ; 14(4): 666-74, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22288430

RESUMEN

The non-invasive leaf patch clamp pressure (LPCP) probe measures the attenuated pressure of a leaf patch, P(p) , in response to an externally applied magnetic force. P(p) is inversely coupled with leaf turgor pressure, P(c) , i.e. at high P(c) values the P(p) values are small and at low P(c) values the P(p) values are high. This relationship between P(c) and P(p) could also be verified for 2-m tall olive trees under laboratory conditions using the cell turgor pressure probe. When the laboratory plants were subjected to severe water stress (P(c) dropped below ca. 50 kPa), P(p) curves show reverse diurnal changes, i.e. during the light regime (high transpiration) a minimum P(p) value, and during darkness a peak P(p) value is recorded. This reversal of the P(p) curves was completely reversible. Upon watering, the original diurnal P(p) changes were re-established within 2-3 days. Olive trees in the field showed a similar turnover of the shape of the P(p) curves upon drought, despite pronounced fluctuations in microclimate. The reversal of the P(p) curves is most likely due to accumulation of air in the leaves. This assumption was supported with cross-sections through leaves subjected to prolonged drought. In contrast to well-watered leaves, microscopic inspection of leaves exhibiting inverse diurnal P(p) curves revealed large air-filled areas in parenchyma tissue. Significantly larger amounts of air could also be extracted from water-stressed leaves than from well-watered leaves using the cell turgor pressure probe. Furthermore, theoretical analysis of the experimental P(p) curves shows that the propagation of pressure through the nearly turgorless leaf must be exclusively dictated by air. Equations are derived that provide valuable information about the water status of olive leaves close to zero P(c) .


Asunto(s)
Olea/fisiología , Hojas de la Planta/fisiología , Agua/fisiología , Deshidratación , Luz , Técnicas de Placa-Clamp , Transpiración de Plantas , Presión
2.
Plant Biol (Stuttg) ; 12(3): 424-36, 2010 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-20522178

RESUMEN

Turgor pressure provides a sensitive indicator for irrigation scheduling. Leaf turgor pressure of Musa acuminate was measured by using the so-called leaf patch clamp pressure probe, i.e. by application of an external, magnetically generated and constantly retained clamp pressure to a leaf patch and determination of the attenuated output pressure P(p) that is highly correlated with the turgor pressure. Real-time recording of P(p) values was made using wireless telemetric transmitters, which send the data to a receiver base station where data are logged and transferred to a GPRS modem linked to an Internet server. Probes functioned over several months under field and laboratory conditions without damage to the leaf patch. Measurements showed that the magnetic-based probe could monitor very sensitively changes in turgor pressure induced by changes in microclimate (temperature, relative humidity, irradiation and wind) and irrigation. Irrigation effects could clearly be distinguished from environmental effects. Interestingly, oscillations in stomatal aperture, which occurred frequently below turgor pressures of 100 kPa towards noon at high transpiration or at high wind speed, were reflected in the P(p) values. The period of pressure oscillations was comparable with the period of oscillations in transpiration and photosynthesis. Multiple probe readings on individual leaves and/or on several leaves over the entire height of the plants further emphasised the great impact of this non-invasive turgor pressure sensor system for elucidating the dynamics of short- and long-distance water transport in higher plants.


Asunto(s)
Musa/fisiología , Hojas de la Planta/fisiología , Transpiración de Plantas , Presión , Ambiente , Fotoperiodo , Fotosíntesis , Agua/fisiología
3.
Radiologe ; 42(1): 33-41, 2002 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-11930539

RESUMEN

PURPOSE: To evaluate the feasibility of performing breast interventions in a vertically open 0.5 T MR system (SIGNA SP/i, GE Medical Systems). To develop fitted equipment and to establish preoperative wire localization and percutaneous breast core biopsy as clinical routine procedures. PATIENTS AND METHODS: Initially, we applied a localization method with the patient placed in a sitting position in 31 cases using a single loop coil and a self-developed fixation device. Subsequently, 46 wire localizations and 28 percutaneous core biopsies were carried out in prone patient position using an open breast coil with an integrated biopsy device. The used instruments were either MR-compatible (18 G biopsy needle and localization wire, 14 G coaxial needle, prototype of a 16 G double-shoot gun) or MR-safe (double-shoot gun with 16 G needle). RESULTS: After biopsy we found the needle tip (18 G for a wire localization and 14 G for a percutaneous core biopsy, respectively) placed either within or close to the lesions (< 10 mm distance) for all patients. Out of a total of 66 benign lesions and 39 malignant tumors we missed the lesion (12 mm mean diameter, 4-25 mm range) during open biopsy in two cases and obtained a false negative result for one percutaneous biopsy of a 5 mm lesion. CONCLUSION: Preoperative wire localization and percutaneous core biopsy of suspicious breast lesions demonstrated by MRI can be carried out a vertically open 0.5 T MR scanner. The degree of accuracy is comparable with that of X-ray or ultrasound-guided procedures. A follow-up has to be performed in cases with a negative biopsy.


Asunto(s)
Biopsia/métodos , Enfermedades de la Mama/diagnóstico , Enfermedades de la Mama/patología , Mama/patología , Imagen por Resonancia Magnética , Adulto , Anciano , Enfermedades de la Mama/cirugía , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Diagnóstico Diferencial , Femenino , Humanos , Persona de Mediana Edad , Postura , Cuidados Preoperatorios , Posición Prona
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA