Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros











Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-35055485

RESUMEN

Doses from the exposure to outdoor radon are typically an order of magnitude smaller than those from indoor radon, causing a greater interest on investigation of the latter for radiation protection issues. As a consequence, assessment of radon priority areas (RPA) is mainly based on indoor radon measurements. Outdoor radon measurements might be needed to guarantee a complete estimation of radiological risk and may help to improve the estimation of RPA. Therefore, authors have analysed the available literature on outdoor radon to give an overview of outdoor radon surveys and potential correlation with indoor radon and estimation of RPA. The review has shown that outdoor radon surveys were performed at much smaller scale compared to indoor radon. Only a few outdoor radon maps were produced, with a much smaller density, covering a larger area, and therefore putting doubt on the representativeness of this data. Due to a large variety of techniques used for outdoor radon measurements and requirement to have detectors with a high sensitivity and resistance to harsh environmental conditions, a standardised measurement protocol should be derived. This is no simple endeavour since there are more applications in different scientific disciplines for outdoor radon measurements compared to indoor radon.


Asunto(s)
Contaminantes Radiactivos del Aire , Contaminación del Aire Interior , Monitoreo de Radiación , Radón , Contaminantes Radiactivos del Aire/análisis , Contaminación del Aire Interior/análisis , Vivienda , Radón/análisis
2.
Artículo en Inglés | MEDLINE | ID: mdl-31443348

RESUMEN

The application of the compact disk (CD) method for radon measurements at mines, caves and other workplaces needs testing under highly variable exposure conditions. We present the results from a blind comparison of CDs exposed in the Laboratory of Natural Radiation (Saelices el Chico, Spain). During the exposure the temperature varied from 6.5 to 24.9 °C (average 12.6 °C) and the 222Rn activity concentrations varied from <10 Bq m-3 to 147 kBq m-3. Good correspondence was observed between the integrated 222Rn activity concentration determined by the reference instruments in the laboratory (122,500 ± 6100 kBq h m-3) and that assessed by analysis of the CDs at a depth 80 µm beneath the front surface (118,000 ± 12,000 kBq h m-3) and at a depth of 120 µm (106,000 ± 12,000 kBq h m-3). The theoretical modeling of the CD response under variable temperature and radon concentration suggested that the small bias is probably due to the time variation of the calibration factor because of the time variations of the temperature.


Asunto(s)
Contaminantes Radiactivos del Aire/análisis , Discos Compactos/estadística & datos numéricos , Monitoreo de Radiación/métodos , Radón/análisis , Calibración , Monitoreo de Radiación/instrumentación , España , Temperatura
3.
J Environ Manage ; 180: 421-32, 2016 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-27266647

RESUMEN

This study deals with the spatiotemporal dynamics of CO2 and its isotopic composition (δ(13)CCO2) in the atmosphere of Altamira Cave (northern Spain) over two annual cycles. In general terms, the cavity shows two distinct ventilation modes, acting as a CO2 reservoir from October to May (recharge stage), while actively exchanging gases with the outside atmosphere between July and September (discharge stage). In recharge mode, the in-cave air shows higher and relatively homogeneous CO2 values (3332 ± 521 ppm) with lower δ(13)CCO2 (-23.2 ± 0.4‰). In contrast, during the discharge stage, the CO2 concentrations are lower and relatively more variable (1383 ± 435 ppm) and accompanied by higher δ(13)CCO2 (up to -12‰). This seasonal pattern is controlled by the distinct rates of exchange of air masses with the external atmosphere through the annual cycle, as well as by changes in the production of CO2 in the soil and natural fluctuations in the concentration of dissolved inorganic carbon transported by drip water into the cave. In contrast to the interpretations of previous studies in Altamira Cave, no local air intakes into the deepest cave sections were flagged by our δ(13)C measurements. This finding is also supported by analyses of CO2 and (222)Rn in air, density of airborne particles and air temperature. In addition, preliminary experiments examining the visitor-produced disturbances on δ(13)CCO2 were conducted during the various cave ventilation stages to explore the potential use of this parameter as an indicator of anthropic pressure in caves. Our data show that visits (overall stay of 60-85 min; i.e., 4 people for 20 min) significantly affected δ(13)CCO2 (up to Δδ(13)C âˆ¼ -2‰) in the Polychrome Hall of Altamira Cave under conditions of low natural CO2 (discharge stage), whereas it remained almost unaltered under circumstances of high CO2 concentration (recharge stage). This demonstrates that δ(13)CCO2 is sensitive to perturbations produced by visitors during certain periods.


Asunto(s)
Contaminantes Atmosféricos/análisis , Dióxido de Carbono/análisis , Cuevas , Atmósfera , Monitoreo del Ambiente , Humanos , España , Temperatura
8.
J Environ Radioact ; 102(4): 378-85, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21382656

RESUMEN

The present paper discusses the results of an empirical study of four approaches to reducing indoor radon concentrations based on depressurization techniques in underground sumps. The experiments were conducted in prototype housing built in an area of Spain where the average radon concentration at a depth of 1 m is 250 kBq m(-3). Sump effectiveness was analysed in two locations: underneath the basement, which involved cutting openings into the foundation, ground storey and roof slabs, and outside the basement walls, which entailed digging a pit alongside the building exterior. The effectiveness of both sumps was likewise tested with passive and forced ventilation methods. The systems proved to be highly efficient, lowering radon levels by 91-99%, except in the solution involving passive ventilation and the outside sump, where radon levels were reduced by 53-55%. At wind speeds of over 8 m/s, however, passive ventilation across an outside sump lowered radon levels by 95% due to a Venturi effect induced drop in pressure.


Asunto(s)
Contaminación del Aire Interior/prevención & control , Contaminación Radiactiva del Aire/prevención & control , Vivienda , Radón/análisis , Ventilación/métodos , Arquitectura , Presión , Monitoreo de Radiación/estadística & datos numéricos , España
SELECCIÓN DE REFERENCIAS