RESUMEN
One of the proposed mechanisms for the development of diabetic nephropathy (DN) is the increase of end products of advanced glycosylation (AGEs), which bind to its receptor (RAGE), favoring nephron cellular damage. An isoform of this receptor is soluble RAGE (sRAGE), which can antagonize AGE-altered intracellular signaling. It has known that green tea extract (GTE) increases the expression of sRAGE, but it is unknown whether this could improve kidney function. The objective of this study was to evaluate the effect of the administration of GTE on the concentrations of sRAGE, renal function, and metabolic profile in patients with type 2 diabetes mellitus (T2DM) and DN. A randomized, double-blinded, placebo-controlled clinical trial was carried out in 39 patients who received GTE (400 mg every 12 h) or placebo for 3 months. sRAGE levels, renal function, and metabolic parameters were determined before and after the intervention. In the GTE group, there were statistically significant increase on sRAGE (320.55 ± 157.63 pg/mL vs. 357.59 ± 144.99 pg/mL; P = .04) and glomerular filtration rate (GFR; 66.44 ± 15.17 mL/min/1.73 m2 vs. 71.70 ± 19.33 mL/min/1.73 m2; P = .04), and a statistically significant decrease in fasting serum glucose (7.62 ± 3.00 mmol/L vs. 5.86 ± 1.36 mmol/L; P ≤ .01) and triacylglycerols (1.91 ± 0.76 mmol/L vs. 1.58 ± 0.69; P = .02). Administration of GTE increases the serum concentration of sRAGE and the GFR and decreases the concentration of fasting serum glucose and triacylglycerols. The study was registered in ClinicalTrials.gov with the identifier NCT03622762.
Asunto(s)
Diabetes Mellitus Tipo 2 , Nefropatías Diabéticas , Extractos Vegetales/farmacología , Receptor para Productos Finales de Glicación Avanzada/sangre , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Nefropatías Diabéticas/tratamiento farmacológico , Humanos , Riñón/fisiología , TéRESUMEN
Type 2 diabetes mellitus (T2DM) is associated with premature atherosclerosis and arterial stiffening due to the accumulation of advanced glycation end-products in vessel walls. Green tea polyphenols are considered cardio-protective substances. In this randomised double-blind placebo-controlled trial (NCT02627898), we evaluated the effect of Green tea extract on arterial stiffness parameters, lipids, body composition and sRAGE levels. Twenty normotensive patients with T2DM treated with the standard therapy and statins, mean age 53.2 ± 9.4 years and mean BMI 30.1 ± 4.5 kg/m2, were randomised to receive a daily dose of 400 mg of green tea extract (polyphenols ≥90%, EGCG ≥45%) or placebo for 12 weeks. Compared to placebo, administration of green tea extract decreased central augmentation index (-3.05 ± 10.8% vs. 6.7 ± 0.1%, p = .04). These findings suggest that green tea extract could be used as an adjunct to the standard therapy to improve arterial stiffness in T2DM.
Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Metabolismo de los Lípidos/efectos de los fármacos , Extractos Vegetales/farmacología , Té/química , Rigidez Vascular/efectos de los fármacos , Adulto , Alanina Transaminasa/sangre , Aspartato Aminotransferasas/sangre , Composición Corporal/efectos de los fármacos , Índice de Masa Corporal , Colesterol/sangre , HDL-Colesterol/sangre , LDL-Colesterol/sangre , Creatinina/sangre , Diabetes Mellitus Tipo 2/sangre , Suplementos Dietéticos , Método Doble Ciego , Femenino , Hemoglobina Glucada/metabolismo , Hemodinámica/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Polifenoles/administración & dosificación , Receptor para Productos Finales de Glicación Avanzada/sangre , Proteínas S100/sangre , Triglicéridos/sangreRESUMEN
Background A correct blood pressure (BP) measurement is essential for the diagnosis and control of high BP. AIM: To evaluate the agreement and repeatability of BP measurements with the OMRON HEM-7320-LA device compared to a mercury sphygmomanometer. MATERIAL AND METHODS: A cross-sectional study comparing BP measurements made by two randomly selected trained nurses and an automatic oscillometric device. The mercurial sphygmomanometer was connected to the automated device via a "T" type connector and a dual-head stethoscope was used, allowing simultaneous measurements. The results were analyzed with one-factor analysis of variance, Bland-Altman's test, repeatability coefficient (RC), and intra-class correlation coefficient (ICC). RESULTS: Forty-nine participants aged 56 ± 19 years were included. Nineteen had hypertension (38%). We did not observe a significant difference in either systolic (SBP) or diastolic blood pressure (DBP) pressure measurements between the observers and the device. The mean difference was -0.09 mmHg (95% confidence intervals (CI)-0.9 to 0.7) for SBP and -0.9 mmHg (95% CI -1.7 to -0.13) for DBP. The RC for SBP (6.2, 5.2 and 5.8 mmHg) and DBP (4.7, 4.2 y 5.2 mmHg) was similar between the observers and the device. The ICC for SBP was 0.990 (95% CI 0.983 to 0.995, p < 0.01) and 0.986 (95% CI 0.977 to 0.991, p < 0.01) for DBP. CONCLUSIONS: There was a high level of agreement and similar measurement repeatability in the measurements performed by the automatic device and the mercurial sphygmomanometer. No differences in BP measurements were observed.
Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Monitores de Presión Sanguínea , Hipertensión/diagnóstico , Determinación de la Presión Sanguínea/métodos , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los ResultadosRESUMEN
Background A correct blood pressure (BP) measurement is essential for the diagnosis and control of high BP. Aim: To evaluate the agreement and repeatability of BP measurements with the OMRON HEM-7320-LA device compared to a mercury sphygmomanometer. Material and Methods: A cross-sectional study comparing BP measurements made by two randomly selected trained nurses and an automatic oscillometric device. The mercurial sphygmomanometer was connected to the automated device via a "T" type connector and a dual-head stethoscope was used, allowing simultaneous measurements. The results were analyzed with one-factor analysis of variance, Bland-Altman's test, repeatability coefficient (RC), and intra-class correlation coefficient (ICC). Results: Forty-nine participants aged 56 ± 19 years were included. Nineteen had hypertension (38%). We did not observe a significant difference in either systolic (SBP) or diastolic blood pressure (DBP) pressure measurements between the observers and the device. The mean difference was −0.09 mmHg (95% confidence intervals (CI)-0.9 to 0.7) for SBP and −0.9 mmHg (95% CI −1.7 to −0.13) for DBP. The RC for SBP (6.2, 5.2 and 5.8 mmHg) and DBP (4.7, 4.2 y 5.2 mmHg) was similar between the observers and the device. The ICC for SBP was 0.990 (95% CI 0.983 to 0.995, p < 0.01) and 0.986 (95% CI 0.977 to 0.991, p < 0.01) for DBP. Conclusions: There was a high level of agreement and similar measurement repeatability in the measurements performed by the automatic device and the mercurial sphygmomanometer. No differences in BP measurements were observed.