Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Invest Ophthalmol Vis Sci ; 59(12): 4998-5010, 2018 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-30326067

RESUMEN

Purpose: To compare the diagnostic capability of three-dimensional (3D) macular parameters against traditional two-dimensional (2D) retinal nerve fiber layer (RNFL) thickness using spectral domain optical coherence tomography. To determine if manual correction and interpolation of B-scans improve the ability of 3D macular parameters to diagnose glaucoma. Methods: A total of 101 open angle glaucoma patients (29 with early glaucoma) and 57 healthy subjects had peripapillary 2D RNFL thickness and 3D macular volume scans. Four parameters were calculated for six different-sized annuli: total macular thickness (M-thickness), total macular volume (M-volume), ganglion cell complex (GCC) thickness, and GCC volume of the innermost 3 macular layers (retinal nerve fiber layer + ganglion cell layer + inner plexiform layer). All macular parameters were calculated with and without correction and interpolation of frames with artifacts. The areas under the receiver operating characteristic curves (AUROC) were calculated for all the parameters. Results: The 3D macular parameter with the best diagnostic performance was GCC-volume-34, with an inner diameter of 3 mm and an outer of 4 mm. The AUROC for RNFL thickness and GCC-volume-34 were statistically similar for all regions (global: RNFL thickness 0.956, GCC-volume-34 0.939, P value = 0.3827), except for the temporal GCC-volume-34, which was significantly better than temporal RNFL thickness (P value = 0.0067). Correction of artifacts did not significantly change the AUROC of macular parameters (P values between 0.8452 and 1.0000). Conclusions: The diagnostic performance of best macular parameters (GCC-volume-34 and GCC-thickness-34) were similar to or better than 2D RNFL thickness. Manual correction of artifacts with data interpolation is unnecessary in the clinical setting.


Asunto(s)
Glaucoma de Ángulo Abierto/diagnóstico , Imagenología Tridimensional/métodos , Fibras Nerviosas/patología , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica/métodos , Anciano , Área Bajo la Curva , Femenino , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Hipertensión Ocular/diagnóstico , Hipertensión Ocular/fisiopatología , Curva ROC , Campos Visuales/fisiología
2.
J Glaucoma ; 26(5): 450-458, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28234677

RESUMEN

PURPOSE: To compare the diagnostic capability of 3-dimensional (3D) neuroretinal rim parameters with existing 2-dimensional (2D) neuroretinal and retinal nerve fiber layer (RNFL) thickness rim parameters using spectral domain optical coherence tomography (SD-OCT) volume scans. MATERIALS AND METHODS: Design: Institutional prospective pilot study. STUDY POPULATION: 65 subjects (35 open-angle glaucoma patients, 30 normal patients). OBSERVATION PROCEDURES: One eye of each subject was included. SD-OCT was used to obtain 2D RNFL thickness values and 5 neuroretinal rim parameters [ie, 3D minimum distance band (MDB) thickness, 3D Bruch's membrane opening-minimum rim width (BMO-MRW), 3D rim volume, 2D rim area, and 2D rim thickness]. MAIN OUTCOME MEASURES: Area under the receiver operating characteristic curve values, sensitivity, and specificity. RESULTS: Comparing all 3D with all 2D parameters, 3D rim parameters (MDB, BMO-MRW, rim volume) generally had higher area under the receiver operating characteristic curve values (range, 0.770 to 0.946) compared with 2D parameters (RNFL thickness, rim area, rim thickness; range, 0.678 to 0.911). For global region analyses, all 3D rim parameters (BMO-MRW, rim volume, MDB) were equal to or better than 2D parameters (RNFL thickness, rim area, rim thickness; P-values from 0.023 to 1.0). Among the three 3D rim parameters (MDB, BMO-MRW, and rim volume), there were no significant differences in diagnostic capability (false discovery rate >0.05 at 95% specificity). CONCLUSIONS: 3D neuroretinal rim parameters (MDB, BMO-MRW, and rim volume) demonstrated better diagnostic capability for primary and secondary open-angle glaucomas compared with 2D neuroretinal parameters (rim area, rim thickness). Compared with 2D RNFL thickness, 3D neuroretinal rim parameters have the same or better diagnostic capability.


Asunto(s)
Glaucoma de Ángulo Abierto/diagnóstico por imagen , Fibras Nerviosas/patología , Disco Óptico/patología , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica/métodos , Anciano , Femenino , Humanos , Imagenología Tridimensional , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Disco Óptico/diagnóstico por imagen , Proyectos Piloto , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad
3.
J Glaucoma ; 26(6): 592-601, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28079657

RESUMEN

PURPOSE: To determine the diagnostic capability of spectral domain optical coherence tomography peripapillary retinal volume (RV) measurements. MATERIALS AND METHODS: A total of 156 patients, 89 primary open-angle glaucoma and 67 normal subjects, were recruited. Spectral domain optical coherence tomography peripapillary RV was calculated for 4 quadrants using 3 annuli of varying scan circle diameters: outer circumpapillary annuli of circular grids 1, 2, and 3 (OCA1, OCA2, OCA3). Area under the receiver operating characteristic curves and pairwise comparisons of receiver operating characteristic (ROC) curves were performed to determine which quadrants were best for diagnosing primary open-angle glaucoma. The pairwise comparisons of the best ROC curves for RV and retinal nerve fiber layer (RNFL) were performed. The artifact rates were analyzed. RESULTS: Pairwise comparisons showed that the smaller annuli OCA1 and OCA2 had better diagnostic performance than the largest annulus OCA3 (P<0.05 for all quadrants). OCA1 and OCA2 had similar diagnostic performance, except for the inferior quadrant which was better for OCA1 (P=0.0033). The pairwise comparisons of the best ROC curves for RV and RNFL were not statistically significant. RV measurements had lower rates of artifacts at 7.4% while RNFL measurements had higher rates at 42.9%. CONCLUSIONS: Peripapillary RV measurements have excellent ability for diagnosing not only glaucoma patients but also a subset of early glaucoma patients. The inferior quadrant of peripapillary annulus OCA1 demonstrated the best diagnostic capability for both glaucoma and early glaucoma. The diagnostic ability of RV is comparable with that of RNFL parameters in glaucoma but with lower artifact rates.


Asunto(s)
Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma/diagnóstico , Retina/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Adulto , Anciano , Área Bajo la Curva , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibras Nerviosas/patología , Valor Predictivo de las Pruebas , Curva ROC , Células Ganglionares de la Retina/patología , Sensibilidad y Especificidad
4.
Invest Ophthalmol Vis Sci ; 57(13): 5498-5508, 2016 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-27768203

RESUMEN

PURPOSE: To describe spectral-domain optical coherence tomography (OCT) methods for quantifying neuroretinal rim tissue in glaucoma and to compare these methods to the traditional retinal nerve fiber layer thickness diagnostic parameter. METHODS: Neuroretinal rim parameters derived from three-dimensional (3D) volume scans were compared with the two-dimensional (2D) Spectralis retinal nerve fiber layer (RNFL) thickness scans for diagnostic capability. This study analyzed one eye per patient of 104 glaucoma patients and 58 healthy subjects. The shortest distances between the cup surface and the OCT-based disc margin were automatically calculated to determine the thickness and area of the minimum distance band (MDB) neuroretinal rim parameter. Traditional 150-µm reference surface-based rim parameters (volume, area, and thickness) were also calculated. The diagnostic capabilities of these five parameters were compared with RNFL thickness using the area under the receiver operating characteristic (AUROC) curves. RESULTS: The MDB thickness had significantly higher diagnostic capability than the RNFL thickness in the nasal (0.913 vs. 0.818, P = 0.004) and temporal (0.922 vs. 0.858, P = 0.026) quadrants and the inferonasal (0.950 vs. 0.897, P = 0.011) and superonasal (0.933 vs. 0.868, P = 0.012) sectors. The MDB area and the three neuroretinal rim parameters based on the 150-µm reference surface had diagnostic capabilities similar to RNFL thickness. CONCLUSIONS: The 3D MDB thickness had a high diagnostic capability for glaucoma and may be of significant clinical utility. It had higher diagnostic capability than the RNFL thickness in the nasal and temporal quadrants and the inferonasal and superonasal sectors.


Asunto(s)
Glaucoma/diagnóstico , Imagenología Tridimensional , Fibras Nerviosas/patología , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica/métodos , Anciano , Estudios Transversales , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA