Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Opt Express ; 26(12): 15247-15254, 2018 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-30114774

RESUMEN

The emission with a bandwidth of 1.5 terahertz based on the spin current in the ferromagnetic heterostructure Co/Pt is demonstrated. The spin transient launched by the NIR femtosecond laser pulse in the Co/Pt is converted into the in-plane charge current due to the inverse spin Hall effect, which gives rise to the terahertz emission towards free space. The dependence of the terahertz emission on the Pt-layer thickness is investigated. To optimize the geometry structure of the new type of emitter, we developed the theoretical model by carefully analyzing the spin transport. Our model reveals the importance to take into account the interfacial spin loss. It can be used to analyze more complex heterostructures.

2.
Clin Radiol ; 72(6): 502-507, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28267987

RESUMEN

AIM: To demonstrate the clinical value of prospective electrocardiography (ECG)-triggered cardiac computed tomography (CT) with low concentration contrast medium, low tube voltage, and adaptive statistic iterative reconstruction (ASIR) to reduce both radiation and contrast dose in examining infants with complex congenital heart disease (CHD). MATERIALS AND METHODS: Forty-four consecutive infants (19 male, 25 female, age: 8.06±4.33 months, weight: 7.31±1.36 kg) with complex CHD underwent prospective ECG-triggered low-dose cardiac CT using 80 kVp and 120 mA. The contrast agent was iodixanol (270 mg iodine/ml, Visipaque, GE Healthcare, Co. Cork, Ireland). Cardiac CT images were reconstructed with 70% ASIR. The quantitative CT image quality was assessed by image noise in adipose tissue and contrast-to-noise ratio (CNR) in the aorta. The qualitative image analysis was performed on a five-point grading scale by two independent reviewers and interobserver variability was calculated. The results of 32 CT examinations were also compared with the available surgical results for diagnostic accuracy evaluation. RESULTS: The effective dose was 0.55±0.10 mSv for the patient population. The iodine load was 3.95±0.73 g iodine. Image noise in adipose tissue was 16.24±1.42 HU and CNR in aorta was 21.90±7.10. All images were acceptable for diagnosis with an average score of 4.52±0.38 and good agreement between reviewers (kappa=0.75). Compared to the surgery results in 32 cases, CT was 97% and 88% accurate diagnosing extracardiac and intracardiac defects, respectively. CONCLUSION: Prospective ECG-triggered cardiac CT using 80 kVp, low-concentration iodinated contrast agent (270 mg iodine/ml) and 70% ASIR reconstruction provides excellent image quality and accurate diagnosis for complex congenital heart disease in infants with reduced contrast medium dose and low radiation dose.


Asunto(s)
Medios de Contraste/administración & dosificación , Electrocardiografía , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/fisiopatología , Tomografía Computarizada por Rayos X , Ácidos Triyodobenzoicos/administración & dosificación , Técnicas de Imagen Cardíaca , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Lactante , Masculino , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA