Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Rev Gaucha Enferm ; 43: e20200399, 2022.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-35613229

RESUMEN

OBJECTIVE: To describe the elaboration and validation of a protocol for the care of suspected patients with Coronavirus Disease-19 (COVID-19) undergoing hemodialysis. METHOD: A methodological study conducted from March to August 2020 at a hospital in southern Brazil. The study involved situational diagnosis, literature review, protocol elaboration and content validation (scope, clarity and relevance). Ten professionals from the multidisciplinary team with experience in caring for patients with kidney disease and an official Nursing supervisory body participated in the validation. 100% consensus was reached among the experts. RESULTS: The following were elaborated: "Flow of patient care consisting of six stages" and "Management plan for dialysis centers". The validation allowed improving and refining the content, complying with the precepts of health standards, safety and clinical guidelines. FINAL CONSIDERATIONS: The elaboration and validation of the protocol can standardize and guide the clinical practice, promoting continuity and safety in care, and can be used in other centers.


Asunto(s)
COVID-19 , Atención de Enfermería , Brasil , COVID-19/epidemiología , COVID-19/terapia , Consenso , Humanos , Diálisis Renal
2.
Rev. gaúch. enferm ; Rev. gaúch. enferm;43: e20200399, 2022. graf
Artículo en Inglés | LILACS-Express | LILACS, BDENF - Enfermería | ID: biblio-1376949

RESUMEN

ABSTRACT Objective: To describe the elaboration and validation of a protocol for the care of suspected patients with Coronavirus Disease-19 (COVID-19) undergoing hemodialysis. Method: A methodological study conducted from March to August 2020 at a hospital in southern Brazil. The study involved situational diagnosis, literature review, protocol elaboration and content validation (scope, clarity and relevance). Ten professionals from the multidisciplinary team with experience in caring for patients with kidney disease and an official Nursing supervisory body participated in the validation. 100% consensus was reached among the experts. Results: The following were elaborated: "Flow of patient care consisting of six stages" and "Management plan for dialysis centers". The validation allowed improving and refining the content, complying with the precepts of health standards, safety and clinical guidelines. Final considerations: The elaboration and validation of the protocol can standardize and guide the clinical practice, promoting continuity and safety in care, and can be used in other centers.


RESUMEN Objetivo: Describir la elaboración y validación de un protocolo para la atención de pacientes sospechosos o con Coronavirus Disease-19 (COVID-19) en hemodiálisis. Método: estudio metodológico realizado de marzo a agosto / 2020 en un hospital del sur de Brasil. El estudio incluyó diagnóstico situacional, revisión de la literatura, elaboración de protocolos y validación de contenido (alcance, claridad y relevancia). En la validación participaron diez profesionales del equipo multidisciplinar con experiencia en el cuidado de pacientes con enfermedad renal y un órgano de control oficial de enfermería. Se alcanzó un consenso del 100% entre los expertos. Resultados: Fueron elaboraron: "Flujo de atención al paciente en seis etapas" y "Plan de gestión para centros de diálisis". La validación permitió mejorar y afinar el contenido, cumpliendo con los preceptos de las normas de salud, seguridad y guías clínicas. Consideraciones finales: La elaboración y validación del protocolo puede estandarizar y orientar la práctica clínica, promoviendo la continuidad y seguridad en la atención, pudiendo ser utilizado en otros centros.


RESUMO Objetivo: Descrever a elaboração e validação de um protocolo para atendimento de pacientes suspeitos ou com Coronavirus Disease-19 (COVID-19) em hemodiálise. Método: Estudo metodológico conduzido de março a agosto/2020 em hospital do sul do Brasil. O estudo envolveu diagnóstico situacional, revisão da literatura, elaboração do protocolo e validação de conteúdo (abrangência, clareza e pertinência). Participaram da validação dez profissionais da equipe multidisciplinar com experiência no atendimento de pacientes com doença renal e um órgão oficial fiscalizatório de enfermagem. Obteve-se 100% de consenso entre os especialistas. Resultados: Foram elaborados: "Fluxo de atendimento para pacientes constituído de seis "etapas" e "Plano gerencial para centros de diálise". A validação permitiu aprimorar e refinar o conteúdo atendendo preceitos de normas sanitárias, segurança e diretrizes clínicas. Considerações finais: A elaboração e validação do protocolo podem padronizar e nortear a prática clínica, promovendo a continuidade e a segurança no cuidado, podendo ser utilizado em outros centros.

3.
Clin. biomed. res ; 41(1): 12-17, 2021. tab
Artículo en Portugués | LILACS | ID: biblio-1255444

RESUMEN

Introdução: A permanência prolongada de Cateter Venoso Central (CVC) em Hemodiálise (HD) está relacionado a maior risco de complicações. O objetivo deste estudo foi avaliar o tempo, em dias, de permanência e o motivo de retirada do CVC em pacientes renais crônicos submetidos à HD ambulatorial em um seguimento de 10 meses. Métodos: Estudo longitudinal, retrospectivo, realizado em unidade de HD de um hospital público no sul do Brasil, no período de janeiro a setembro/2019. A coleta de dados foi realizada pelos pesquisadores a partir de prontuário eletrônico e planilha de registros dos doentes renais crônicos em hemodiálise por CVC de curta e longa permanência no período em estudo. Projeto aprovado no Comitê de Ética em Pesquisa da instituição. Resultados: Foram avaliados 91 cateteres de 55 pacientes, com prevalência do sexo feminino 33 (60%), média de idade 55 ± 18 anos e cor branca 42 (76,3%). Quarenta e sete (52%) dos CVCs eram de curta permanência, e 70 (76,9%) inseridos em veia jugular direita. O tempo de hemodiálise com CVCs de curta permanência variou de quatro a 190 dias com mediana de 47 dias (21, 7-69, 3) e os de longa permanência de 47 a 1.486 dias, com mediana de 231 (95-676). O principal motivo de retirada dos cateteres foi a troca por outro CVC 17 (36,2%). A taxa de suspeita e/ou infecção foi de 14 (15,4%). Conclusão: O tempo de permanência dos CVC foi prolongado o que expõe os pacientes a riscos. O principal motivo para retirar o CVC não foi a confecção de Fístula Arteriovenosa (FAV), apontando para a necessidade de revisar os processos assistenciais visando modificar e priorizar essa prática. (AU)


Introduction: The prolonged permanence of Central Venous Catheter (CVC) in Hemodialysis (HD) is related to an increased risk of complications. The aim of this study was to evaluate duration of use, in days, and reasons for removal of central venous catheter (CVC) in patients with chronic kidney disease undergoing ambulatory hemodialysis in a 10-month follow-up. Methods: This longitudinal, retrospective study was conducted at the hemodialysis unit of a public hospital in southern Brazil, from January to September 2019. Data collection was performed by the researchers using electronic medical records and a spreadsheet of records of patients with chronic kidney disease undergoing hemodialysis by short- and long-term CVC in the study period. The project was approved by the institution's Research Ethics Committee. Results: Ninety-one catheters from 55 patients were evaluated. Thirty-three participants were female (60%), mean age was 55 ± 18 years, and 42 were white (76.3%). Forty-seven (52%) CVCs were short-term, and 70 (76.9%) CVCs were inserted in the right jugular vein. Hemodialysis duration with short-term CVCs ranged from four to 190 days with a median of 47 (21.7-69.3) days, and long-term CVCs ranged from 47 to 1486 days with a median of 231 (95-676) days. The main reason for removing the catheter was replacing it with another CVC, in 17 cases (36.2%). The number of cases of infection or suspected infection was 14 (15.4%). Conclusions: The duration of CVC use was prolonged, which exposes patients to risks. The main reason for removing the CVC was not related to creating an arteriovenous fistula, demonstrating the need to review the care processes aiming to modify and prioritize this practice. (AU)


Asunto(s)
Humanos , Masculino , Femenino , Diálisis Renal , Catéteres Venosos Centrales/estadística & datos numéricos , Efectos Adversos a Largo Plazo , Pacientes/estadística & datos numéricos , Estudios Longitudinales , Insuficiencia Renal Crónica
4.
Acta Paul. Enferm. (Online) ; 33: eAPE20190119, 2020. tab, graf
Artículo en Portugués | LILACS, BDENF - Enfermería | ID: biblio-1130569

RESUMEN

Resumo Objetivos Comparar a reutilização do dialisador com o uso único deste material para marcadores bioquímicos, hematológicos, episódios de pirogenias e bacteremias. Métodos Estudo longitudinal com coleta de dados retrospectiva em prontuários de pacientes em hemodiálise, em hospital público universitário. A investigação foi conduzida seis meses com a reutilização do dialisador e seis meses com uso único. Os dados foram analisados no SPSS Versão 18.0. Para comparação das médias dos exames utilizou-se teste t pareado e Wilcoxon, episódios de pirogenia e bacteremia foram analisados pelo teste de Wilcoxon e Razão de Chances (RC) como medida de força de associação. Variáveis categóricas foram analisadas pelos testes de McNemar e Exato de Fisher. O estudo foi aprovado pelo Comitê de Ética e Pesquisa. Resultados Foram analisadas 5.508 sessões de hemodiálise de pacientes predominantemente masculinos 21(62%), média de idade 58(± 14) anos, hipertensos 14(41%), tempo médio de tratamento 6±3 anos. Durante uso único identificou-se redução da ureia pós diálise, creatinina, fósforo, ferritina, hematócrito e hemoglogina em relação ao reutilizado (p < 0,05) e 91% menos risco de pirogenia comparado a reutilização do dialisador (Razão de Chance= 0,091; IC 95%: 0,002-0,625). Não houve diferença significativa na ocorrência de bacteremias. Conclusão Os resultados sugerem maior remoção de biomarcadores bioquímicos e menos episódios de pirogenias quando o dialisador é uso único.ater removal of biochemical biomarkers and fewer pyrogenics episodes when the dialyzer is a single use.


Resumen Objetivos Comparar la reutilización del dializador con el uso único de este material en marcadores bioquímicos, hematológicos, episodios de reacciones pirógenas y bacteriemias. Métodos Estudio longitudinal con recolección de datos retrospectiva en historias clínicas de pacientes en hemodiálisis, en un hospital público universitario. La investigación fue conducida seis meses con la reutilización del dializador y seis meses con un único uso. Los datos fueron analizados en SPSS Versión 18.0. Para comparar los promedios de los análisis, se utilizó el Test-T pareado y prueba de Wilcoxon, los episodios de reacciones pirógenas y bacteriemia fueron analizados mediante la prueba de Wilcoxon y Razón de Momios (RM) como medida de fuerza de asociación. Las variables categóricas se analizaron con la prueba de McNemar y la prueba exacta de Fisher. El estudio fue aprobado por el Comité de Ética e Investigación. Resultados Se analizaron 5.508 sesiones de hemodiálisis de pacientes predominantemente masculinos 21 (62 %), promedio de edad 58 (±14) años, hipertensos 14 (41 %), tiempo promedio de tratamiento 6±3 años. Durante el uso único del dializador, se identificó una reducción de la urea posdiálisis, creatinina, fósforo, ferritina, hematocrito y hemoglobina respecto al dializador reutilizado (p < 0,05) y un 91 % menos de riesgo de reacción pirógena comparado con la reutilización del dializador (Razón de Momios = 0,091; IC 95 %: 0,002-0,625). No hubo diferencia significativa en episodios de bacteriemias. Conclusión Los resultados sugieren mayor eliminación de biomarcadores bioquímicos y menos episodios de reacciones pirógenas cuando el dializador se utiliza una única vez.


Abstract Objectives To compare dialyzer reuse with its single use for biochemical, hematological markers, pyrogenesis and bacteremia episodes. Methods A longitudinal study with retrospective data collection from medical records of patients on dialysis in a public university hospital. The investigation was conducted six months with dialyzer reuse and six months with single use. Data were analyzed using SPSS Version 18.0. To compare the tests means, paired t-test and Wilcoxon were used. Pyrogenesis and bacteremia episodes were analyzed using the Wilcoxon test and Odds Ratio (OR) as association strength measures. Categorical variables were analyzed using McNemar and Fisher's Exact tests. The study was approved by the hospital's Research Ethics Committee. Results Five thousand five hundred eight dialysis sessions of predominantly male patients were analyzed, 21 (62%), with mean age of 58 (± 14) years, hypertensive 14 (41%), with mean treatment time 6 ± 3 years. During single use, a reduction in urea after dialysis, creatinine, phosphorus, ferritin, hematocrit and hemoglogin was identified in relation to reuse (p<0.05) and 91% less risk of pyrogenesis compared to dialyzer reuse (Odds Ratio=0.091; 95% CI: 0.002-0.625). There was no significant difference in the occurrence of bacteremia. Conclusion The results suggest greater removal of biochemical biomarkers and fewer pyrogenics episodes when the dialyzer is a single use.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Pirógenos , Diálisis Renal/efectos adversos , Bacteriemia , Equipo Reutilizado , Estudios Retrospectivos , Estudios Longitudinales , Registros Electrónicos de Salud
5.
Rev Esc Enferm USP ; 52: e03389, 2018 Dec 13.
Artículo en Portugués, Inglés, Español | MEDLINE | ID: mdl-30570080

RESUMEN

OBJECTIVE: To compare the reports of occupational events recorded by nursing professionals during the periods of reuse and single use of the dialyzer. METHOD: Retrospective longitudinal study with electronic medical records from nursing technicians of a hemodialysis service. Data were analyzed descriptively and Rate ratio. RESULTS: During the reuse of the dialyzer, there were seven events from five professionals reporting musculoskeletal disorders, ocular allergies and dermatosis. During single use, two professionals reported low back pain. The rate ratio of medication use was 6.7 days for every 1000 professionals during the reuse period and 1.52 days in the single use period (RR=4.4; 95% CI 2.182-9.805). Anti-inflammatory drugs were the most prescribed, and sick leaves were similar in both periods. CONCLUSION: Dialyzer reuse was associated with musculoskeletal disorders, ocular irritation, dermatosis and increased use of medications by professionals. Sick leaves were similar on the periods of dialyzer reuse and single use.


Asunto(s)
Asistentes de Enfermería/estadística & datos numéricos , Enfermedades Profesionales/epidemiología , Diálisis Renal/métodos , Adulto , Registros Electrónicos de Salud , Equipo Reutilizado/estadística & datos numéricos , Oftalmopatías/epidemiología , Femenino , Humanos , Hipersensibilidad/epidemiología , Estudios Longitudinales , Dolor de la Región Lumbar/epidemiología , Masculino , Persona de Mediana Edad , Enfermedades Musculoesqueléticas/epidemiología , Estudios Retrospectivos , Enfermedades de la Piel/epidemiología
6.
Rev Gaucha Enferm ; 38(3): e66789, 2018 Mar 12.
Artículo en Portugués, Inglés | MEDLINE | ID: mdl-29538608

RESUMEN

OBJECTIVE: To validate interventions and nursing activities proposed by the Nursing Interventions Classification for patients with acute renal failure or acute chronic renal disease in hemodialysis therapy with the Excess Fluid Volume and Risk for Imbalanced Fluid Volume nursing diagnoses. METHODS: Validation of content with 19 expert nurses from a university hospital. The data collection was made from September to November 2011 through instruments that contained the interventions and nursing activities in study. The data analysis considered the average of scores obtained in the validation process. RESULTS: The Fluid Management was validated as a priority intervention (mean ≥ 0.8), with eight main activities for the Excess Fluid Volume nursing diagnosis and eight for the Risk for Imbalanced Fluid Volume nursing diagnosis. CONCLUSION: The validated intervation of the Fluid Management enables the monitoring of the hydric balance and facilitates the prevention of complications, which are important activities in the nursing care of the patients in hemodialysis therapy.


Asunto(s)
Diálisis Renal/enfermería , Lesión Renal Aguda/enfermería , Lesión Renal Aguda/terapia , Femenino , Unidades de Hemodiálisis en Hospital , Hospitales Universitarios , Humanos , Unidades de Cuidados Intensivos , Fallo Renal Crónico/enfermería , Fallo Renal Crónico/terapia , Masculino , Diagnóstico de Enfermería , Diálisis Renal/efectos adversos , Especialidades de Enfermería , Equilibrio Hidroelectrolítico , Desequilibrio Hidroelectrolítico/etiología , Desequilibrio Hidroelectrolítico/enfermería , Desequilibrio Hidroelectrolítico/prevención & control
7.
Rev. Esc. Enferm. USP ; Rev. Esc. Enferm. USP;52: e03389, 2018. tab
Artículo en Inglés, Español, Portugués | LILACS, BDENF - Enfermería | ID: biblio-985065

RESUMEN

RESUMO Objetivo: Comparar as ocorrências ocupacionais registradas pelos profissionais de Enfermagem durante a utilização do dialisador reutilizado e de uso único. Método: Estudo longitudinal, retrospectivo, realizado com prontuários de técnicos de Enfermagem de um serviço de hemodiálise. Os dados foram analisados descritivamente e calculados pela Razão de Densidade de Incidência. Resultados: Durante a reutilização do dialisador, foram registradas sete notificações de cinco profissionais relacionadas a distúrbios osteomusculares, a alergias oculares e à dermatose. Durante o uso único, dois profissionais registraram dor lombar. A taxa de exposição ao uso de medicamentos foi de 6,7 dias para cada 1.000 profissionais no período de reutilização do dialisador e de 1,52 dias no período de uso único (RDI=4,4; IC 95%: 2.182-9.805). Os anti-inflamatórios foram os mais prescritos, e os afastamentos do trabalho foram semelhantes nos dois períodos. Conclusão: O reúso do dialisador esteve associado a distúrbios osteomusculares, irritação ocular, dermatoses e maior uso de medicamentos pelos profissionais. Os afastamentos do trabalho foram semelhantes durante o uso do dialisador reutilizado e de uso único.


ABSTRACT Objective: To compare the reports of occupational events recorded by nursing professionals during the periods of reuse and single use of the dialyzer. Method: Retrospective longitudinal study with electronic medical records from nursing technicians of a hemodialysis service. Data were analyzed descriptively and Rate ratio. Results: During the reuse of the dialyzer, there were seven events from five professionals reporting musculoskeletal disorders, ocular allergies and dermatosis. During single use, two professionals reported low back pain. The rate ratio of medication use was 6.7 days for every 1000 professionals during the reuse period and 1.52 days in the single use period (RR=4.4; 95% CI 2.182-9.805). Anti-inflammatory drugs were the most prescribed, and sick leaves were similar in both periods. Conclusion: Dialyzer reuse was associated with musculoskeletal disorders, ocular irritation, dermatosis and increased use of medications by professionals. Sick leaves were similar on the periods of dialyzer reuse and single use.


RESUMEN Objetivo: Comparar las ocurrencias ocupacionales registradas por los profesionales enfermeros durante la utilización del dializador reutilizado y de uso único. Método: Estudio longitudinal, retrospectivo, realizado con fichas de técnicos de Enfermería de un servicio de hemodiálisis. Los datos fueron analizados descriptivamente y calculados por la Razón de Densidades de Incidencia. Resultados: Durante la reutilización del dializador, fueron registradas siete notificaciones de cinco profesionales relacionadas con disturbios osteomusculares, alergias oculares y dermatosis. Durante el uso único, dos profesionales registraron dolor lumbar. La tasa de exposición al uso de fármacos fue de 6,7 días para cada 1.000 profesionales en el período de reutilización del dializador y de 1,52 días en el período de uso único (RDI=4,4; IC 95%: 2.182-9.805). Los antiinflamatorios fueron los más prescritos, y las bajas laborales fueron semejantes en ambos períodos. Conclusión: El reúso del dializador estuvo asociado con disturbios osteomusculares, irritación ocular, dermatosis y mayor uso de fármacos por los profesionales. Las bajas laborales fueron semejantes durante el uso del dializador reutilizado y de uso único.


Asunto(s)
Diálisis Renal , Equipo Reutilizado , Enfermeros no Diplomados , Grupo de Enfermería , Riesgos Laborales , Salud Laboral
8.
Rev. gaúch. enferm ; Rev. gaúch. enferm;38(3): e66789, 2017. tab
Artículo en Portugués | LILACS, BDENF - Enfermería | ID: biblio-901653

RESUMEN

RESUMO Objetivo Validar intervenções e atividades de enfermagem propostas pela Nursing Interventions Classification, para pacientes com insuficiência renal aguda ou doença renal crônica agudizada, em terapia hemodialítica com os diagnósticos de enfermagem Volume de Líquidos Excessivo e Risco de Volume de Líquidos Desequilibrado. Métodos Validação de conteúdo com 19 enfermeiros peritos de um hospital universitário. A coleta de dados ocorreu de setembro a novembro de 2011, por meio de instrumentos que continham as intervenções e atividades de enfermagem em estudo. A análise considerou a média dos escores obtidos na validação. Resultados O Controle Hídrico foi validado como intervenção prioritária (média ≥ 0.8), com oito atividades principais para o diagnóstico Volume de Líquidos Excessivo e oito para o diagnóstico Risco de Volume de Líquidos Desequilibrado. Conclusão A intervenção validada de Controle Hídrico possibilita o monitoramento do equilíbrio hídrico e facilita a prevenção de complicações, consideradas importantes atividades do cuidado ao paciente em terapia hemodialítica.


RESUMEN Objectivo Validar intervenciones y actividades de enfermería propuestas por la Nursing Interventions Classification, para pacientes con insuficiencia renal aguda o enfermedad renal crónica agudizada, en terapia hemodialítica con los diagnósticos de enfermería Volumen de Líquidos Excesivo y Riesgo de Desequilibrio de Volumen de Líquidos. Métodos Validación de contenido con 19 enfermeros expertos de un hospital universitario. La recolección de datos fue realizada de septiembre a noviembre de 2011 con instrumentos que contenían las intervenciones y actividades de enfermería en estudio. El análisis consideró el promedio de los puntajes obtenidos en la validación. Resultados El Manejo de Líquidos fue validado como intervención prioritaria (media >0.8), con ocho actividades principales para el diagnóstico Volumen de Líquidos Excesivo y ocho para el diagnóstico Riesgo de Desequilibrio de Volumen de Líquidos. Conclusión La intervención validada de Manejo de Líquidos posibilita el monitoreo del balance hídrico y facilita la prevención de complicaciones, consideradas importantes actividades del cuidado al paciente en terapia hemodialítica.


ABSTRACT Objective To validate interventions and nursing activities proposed by the Nursing Interventions Classification for patients with acute renal failure or acute chronic renal disease in hemodialysis therapy with the Excess Fluid Volume and Risk for Imbalanced Fluid Volume nursing diagnoses. Methods Validation of content with 19 expert nurses from a university hospital. The data collection was made from September to November 2011 through instruments that contained the interventions and nursing activities in study. The data analysis considered the average of scores obtained in the validation process. Results The Fluid Management was validated as a priority intervention (mean ≥ 0.8), with eight main activities for the Excess Fluid Volume nursing diagnosis and eight for the Risk for Imbalanced Fluid Volume nursing diagnosis. Conclusion The validated intervation of the Fluid Management enables the monitoring of the hydric balance and facilitates the prevention of complications, which are important activities in the nursing care of the patients in hemodialysis therapy.


Asunto(s)
Humanos , Masculino , Femenino , Diálisis Renal/enfermería , Especialidades de Enfermería , Equilibrio Hidroelectrolítico , Desequilibrio Hidroelectrolítico/enfermería , Desequilibrio Hidroelectrolítico/etiología , Desequilibrio Hidroelectrolítico/prevención & control , Diagnóstico de Enfermería , Diálisis Renal/efectos adversos , Lesión Renal Aguda/enfermería , Lesión Renal Aguda/terapia , Unidades de Hemodiálisis en Hospital , Hospitales Universitarios , Unidades de Cuidados Intensivos , Fallo Renal Crónico/enfermería , Fallo Renal Crónico/terapia
9.
In. Associaçäo Brasileira da Enfermagem. Anais do 11§ Encontro de Enfermagem na Regiäo Sul: a trajetória da enfermagem na Regiäo Sul: um olhar sobre o passado, o presente e o futuro. Porto Alegre, Associaçäo Brasileira de Enfermagem, 2000. p.86-7.
Monografía en Portugués | LILACS | ID: lil-290654
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA