1.
Meat Sci ; 57(1): 61-70, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22061168

RESUMEN

Pork fat samples from 50 boars slaughtered at a commercial abattoir were analysed for skatole and androstenone concentrations and grouped within a 3×3 matrix representing low, medium and high levels of the odour compounds. A 10 member sensory panel, screened and trained to recognise and quantify skatole and androstenone odour intensities, was used to verify the human perception of boar odour in these pork fat samples immediately after heating (±65°C) and following a cooling period of ten minutes (±25°C). Principal component analysis revealed that the sensory panel differentiated the pork fat samples first and foremost on the basis of the presence or absence of androstenone and/or skatole odours and secondly on the character of the androstenone or skatole odour. Evidence of adaptation towards the odour of skatole was shown by a decreased sensitivity over replicates. Sensory perception of boar odour seems to have a temporal character which can be explained by differences in volatilisation (involving both odourant release and retention) of skatole and androstenone, odour synergism and possibly differences in the properties of the fat matrix of different samples. The results suggest that factors influencing volatilisation of skatole and androstenone should also be considered when predicting sensory responses of boar odour.

2.
Meat Sci ; 52(3): 331-7, 1999 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22062583

RESUMEN

The effect of electrical and captive needle air pressure stunning methods on some meat quality parameters was examined in ostriches under practical conditions. One hundred and fifteen ostriches were used in three experiments. The ostriches were stunned either electrically (head only) or by using a captive needle with air pressure. In the first experiment the ostriches were stunned at 90 V (∼effectively 52 V), 200 V and by captive needle using air pressure. In the second experiment voltages of 175 and 200 V were applied and a captive needle stunning method using air pressure. In the third experiment the birds were stunned at 175 V with a short stun/stick interval. Experiments 2 and 3 were performed in a different slaughterhouse from experiment 1. Meat quality was assessed by measuring the pH, temperature and colour at 45 min and 18 h post mortem and by determining water binding capacity and haemorrhage score at 18 h post mortem in the big drum, tender loin and triangular filet muscles. The measured stunning parameters in the first experiment were 204±96 mA (∼52 V) during 11±1 s and 556±85 mA (∼200 V) during 6±0 s. The stun/stick interval was 136±38 s. The rigor mortis value in the tender loin and both pH(1) and pH(2) in the big drum, tender loin and triangular filet muscles were (p<0.05) lower when stunned with air pressure compared with electrical stunning. Moreover internal light scattering remained higher. The measured currents in the second experiment were 561±226 mA (∼173 V) during 6±2 s and 518±120 mA (∼200 V) during 6 s. The stun/stick interval was 39±12 s. The pH at 45 min and 18 h differed (p<0.05) in the tender loin and triangular filet muscles as did the temperature at 45 min in the three muscles between the different stunning groups. The stunning in the third experiment was carried out with 548±180 mA during 6±2 s. The stun/stick interval was 5±2 s. After the short stun/stick interval the pH(2) was lower (p<0.05) for the tender loin and triangular filet muscles and the wetness of the filter paper of the big drum was (p<0.05) lower compared with the other groups. Our experiments showed that stunning methods affected several meat quality parameters. Using a high electrical stunning current, captive needle stunning or a short stun/stick interval may positively affect some parameters. More research is necessary to examine effects of pre slaughter handling on meat quality.

3.
Meat Sci ; 52(4): 339-45, 1999 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22062694

RESUMEN

Different electrical and mechanical stunning procedures were studied in ostriches to determine the effectiveness of the method. Fifty-eight South-African Black ostriches were equipped with EEG electrodes and stunned with three different electrical head-only methods and with a new captive needle pistol, using air pressure. The first stunning procedure consists of two trials. In the first trial a total of 45 ostriches were stunned with a voltage of 200V (spiked electrodes) during 1s. Unfortunately, in 10 animals the electrodes were disconnected. A general epileptiform insult on the EEG followed by recovery was observed in 20 ostriches. Another eight animals died after recovery and five showed an iso-electric line and were dead. The total duration of the insult was 25±10s. The measured current was 463±120mA. In the second trial a constant current of 400mA was administered to 13 ostriches. In one animal the electrodes were disconnected. Eight out of 12 animals showed a general epileptiform insult, two of them showed an iso-electric line and two did not show the characteristics of a general epileptiform insult. The total duration of the insult on the EEG was 21±8s. The measured current was 365±91mA and the voltage 191±27V. During the second stunning procedure four and seven ostriches were stunned with 200V (spiked electrodes) and 48V (blunt electrodes), respectively, during approx. 6s. They all died. In addition, a group of 20 ostriches stunned with captive needle pistol using air pressure showed unconsciousness after stunning by the appearance of theta and delta waves tending to an iso-electric line on the EEG trace. It is recommended to use at least 500mA to stun ostriches effectively and to use a short stun-stick interval or to kill them by a long stunning duration. The captive needle pistol, using air pressure, can be an alternative for electrical head-only stunning.