Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Catheter Cardiovasc Interv ; 87(1): 73-4, 2016 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-27410955

RESUMEN

Coronary stents are commonly deployed using high pressure. However, the duration time of balloon inflation during deployment is still to be determined. Vallurupalli and coworkers, in this issue of CCI, show that the stent system takes an average of 33 sec to "accommodate" its pressure during in vitro deployment. In patients, the mean stent inflation time to achieve pressure stability was 104 seconds, ranging from 30 to 380 sec. These results challenge a rapid inflation/deflation approach for stent deployment. It is suggested that the duration of the inflation might be individualized, in a case-by-case approach. However, the findings must be interpreted with caution, as they cannot be directly extrapolated to more diverse clinical, angiographic, and interventional scenarios.


Asunto(s)
Enfermedad Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Stents , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico , Humanos , Intervención Coronaria Percutánea/normas , Presión , Factores de Tiempo , Resultado del Tratamiento
2.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 26(2): 128-133, abr.-jun.2016. tab
Artículo en Portugués | LILACS | ID: lil-796517

RESUMEN

Aproximadamente 30% dos pacientes que se apresentam com quadro de síndrome coronariana aguda têm revascularização prévia do miocárdio. Os eventos coronarianos subsequentes à revascularização do miocárdio podem ocorrer por progressão da doença aterosclerótica no leito coronário nativo, evento relacionado ao stent (reestenose, trombose ou neoaterosclerose) ou evento relacionado à cirurgia de revascularização domiocárdio (degeneração ou oclusão de enxertos cirúrgicos). Esses pacientes que necessitamde um novo procedimento de revascularização têm perfil de alto risco, geralmente associado a doença renal crônica, diabetes mellitus, doença arterial periférica, além deelevada carga aterosclerótica no leito coronariano nativo, degeneração de enxertos de veia safena e reestenose de stents. Este cenário faz com que o segundo procedimento de revascularização tenha maior risco e maior complexidade. Neste artigo discutiremos as características clínicas e as possibilidades terapêuticas de pacientes com SCA e revascularização percutânea ou cirúrgica prévias.


Around 30% of patients who present acute coronary syndrome have undergone previous myocardial revascularization. Coronary events following myocardial revascularization can occur due to progression of atherosclerotic disease in the native coronary bed, an event related to the stent (restenosis, thrombosis or neoatherosclerosis) or to the myocardial revascularization surgery (degeneration or occlusion of surgical grafts). These patients who need a new revascularization procedure have a high-risk profile, generally associated with chronic kidney disease, diabetes mellitus, and peripheral arterial disease, as well as a high atherosclerotic burden in the native coronary bed, degeneration of grafts of the saphenous vein, and restenosis of stents. This scenario confers a higher risk and greater complexity on the second revascularization procedure. In this article, we discuss the clinical characteristics and therapeutic possibilities of patients with ACS and previous percutaneous or surgical revascularization.


Asunto(s)
Humanos , Intervención Coronaria Percutánea/métodos , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/terapia , Revascularización Miocárdica/efectos adversos , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia , Angioplastia/métodos , Enfermedad Aguda , Factores de Riesgo , Stents , Trombosis/diagnóstico , Trombosis/terapia , Vasos Coronarios/cirugía , Vena Safena , Ventrículos Cardíacos
3.
In. Kalil Filho, Roberto; Fuster, Valetim; Albuquerque, Cícero Piva de. Medicina cardiovascular reduzindo o impacto das doenças / Cardiovascular medicine reducing the impact of diseases. São Paulo, Atheneu, 2016. p.631-654.
Monografía en Portugués | LILACS | ID: biblio-971558
4.
Rev. bras. cardiol. invasiva ; 23(1): 58-60, abr.-jun.2015. tab
Artículo en Portugués | LILACS | ID: lil-782177

RESUMEN

O objetivo deste estudo foi avaliar o grau de acurácia, precisão, correlação e concordância entre as medidas realizadas por um software de angiografia coronária quantitativa (QCA) online de calibração automática. Métodos: Estudo piloto que analisou imagens angiográficas de dez pacientes com um software de QCA online nas calibrações automáticas Auto ISO (calibração automática do isocentro) e Auto TOD (Table-to Object Distance). Foi realizada a medida do calibre do cateter pelos dois métodos, e o diâmetro de referência foi computado. Essas medidas foram comparadas com a medida do diâmetro do cateter quanto à acurácia, precisão e concordância. Resultados: O diâmetro médio real dos cateteres era de 1,75 ± 0,32 mm (variando entre 1,33 e 2,67 mm). A aferição dos cateteres pela QCA TOD e pela QCA ISO resultou em diâmetros médios de 1,78 ± 0,37 mm e 1,88 ± 0,38 mm, respectivamente. A acurácia/precisão da QCA TOD e da QCA ISO foi 0,03 m/0,21 mm e 0,12 mm/0,20 mm, respectivamente. As medidas da QCA TOD e da QCA ISO estiveram entre os limites de concordância em 96,3 e 94,7% dos casos, respectivamente. As medidas da QCA TOD e da QCA ISO correlacionaram-se significativamente (rs = 0,93; p < 0,01). No entanto, apesar da pequena diferença entre os métodos (0,10 ± 0,10 mm), as medidas da QCA ISO foram estatisticamente maiores que aquelas obtidas com a QCA TOD (p < 0,01). Conclusões: A QCA online com calibração automática apresentou boa acurácia, precisão e correlação,podendo representar uma ferramenta promissora no laboratório de hemodinâmica...


The objective of this study was to evaluate the degree of accuracy, precision, correlation, andagreement between the measurements performed by online Quantitative Coronary Angiography (QCA)software with automatic calibration.Methods: Pilot study that analyzed angiographic images of ten patients through online QCA softwareusing Auto ISO (automatic calibration isocenter) and Auto TOD (Table-to-Object Distance) automatic calibration. Catheter size was measured by both methods and the reference diameter was computed. These measurements were compared with the measurement of catheter diameter regarding accuracy, precision,and agreement. Results: The actual average of the catheter diameter was 1.75 ± 0.32 mm (range 1.33 to 2.67 mm). The measurement of catheters by TOD QCA and ISO QCA resulted in mean diameters of 1.78 ± 0.37 mm and 1.88± 0.38 mm, respectively. The accuracy/precision of the TOD QCA and the ISO QCA was 0.03 mm/0.21 mmand 0.12 mm/0.20 mm, respectively. The TOD QCA and ISO QCA measures were among the limits ofagreement in 96.3 and 94.7% of cases, respectively, and were significantly correlated (rs = 0.93, p < 0.01). However, despite the small difference between the methods (0.10 ± 0.10 mm), the ISO QCA measures were significantly higher than those obtained by the TOD QCA (p < 0.01). Conclusions: Online QCA with automatic calibration has good accuracy, precision, and correlation, which may represent a promising tool in the catheterization laboratory...


Asunto(s)
Humanos , Masculino , Femenino , Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico , Enfermedad Coronaria/terapia , Precisión de la Medición Dimensional , Interpretación Estadística de Datos , Catéteres , Proyectos Piloto , Stents
5.
Rev. bras. cardiol. invasiva ; 23(1): 38-41, abr.-jun.2015. tab, graf
Artículo en Portugués | LILACS | ID: lil-782173

RESUMEN

A aterectomia rotacional com incorporação de novas estratégias ablativas tem sido proposta para o preparo de lesões extremamente calcificadas. Entretanto, pouco se conhece a respeito da adoçãodessas novas estratégias na prática contemporânea e sobre a evolução tardia dos pacientes submetidos aesse tratamento. Objetivamos avaliar os aspectos técnicos da aterectomia e a evolução tardia dos pacientesquanto à ocorrência de eventos cardiovasculares adversos maiores (ECAM). Métodos: Estudo retrospectivo e unicêntrico, incluindo todos os pacientes submetidos à aterectomiarotacional como parte do tratamento de lesões coronárias com calcificação extrema ou falha de dilataçãoem procedimento prévio, no período de julho de 2012 a novembro de 2014. Foram definidos como ECAM: óbito, infarto agudo do miocárdio com onda Q ou nova revascularização do vaso-alvo.Resultados: Foram submetidos à aterectomia 29 pacientes com idade média de 69,5 ± 7,6 anos. A médiada relação oliva/vaso foi de 0,54 ± 0,07; a velocidade de rotação inicial adotada foi de 161.000 ± 13.928 e a taxa de utilização de cutting balloon pós-aterectomia foi de 45,1%. Sucesso angiográfico foi obtido em todos os procedimentos. Na evolução tardia, a mediana de tempo de seguimento foi de 13,2 meses (intervalo interquartil: 4,0 a 17,4 meses). Foram registrados um óbito por causa não cardíaca e duas novas revascularizações do vaso-alvo. A média do tempo de sobrevivência livre de ECAM foi de 29,7 ± 2,1 meses.Conclusões: A aterectomia rotacional contemporânea incorporou estratégias menos agressivas de ablação,com elevada taxa de sucesso imediato e baixa ocorrência de ECAM na evolução tardia...


Rotational atherectomy with new ablative strategies have been proposed for the treatment of extremely calcified lesions prior to stent implantation. Nevertheless, few data are available about the adoption of these new strategies in contemporary practice and about late outcomes of patients undergoing this therapy. Methods: From July 2012 to November 2014, a retrospective single center registry was conducted, including all patients undergoing rotational atherectomy as part of the treatment of coronary arteries with heavy calcification or previous failed dilation. We evaluated technical aspects of atherectomy and late outcomes of patients for the occurrence of major adverse cardiovascular events (MACE), defined as death, Q-wave myocardial infarction or repeat target vessel revascularization.Results: Twenty-nine patients with a mean age of 69.5 ± 7.6 years, underwent atherectomy. The averageburr-to-artery ratio was 0.54 ± 0.07, the initial rotational speed was 161.000 ± 13.928 and the rate of cuttingballoon utilization after atherectomy was 45.1%. Angiographic success was achieved in all procedures. The median follow-up time was 13.2 months (IQ: 4.0-17.4) and there were three events: 1 death of non cardiac cause and 2 new target vessel revascularizations. The mean MACE-free survival time was 29.7 ± 2.1 months. Conclusions: Contemporary rotational atherectomy incorporates less aggressive strategies of ablation with high rates of acute success and low occurrence of major adverse cardiovascular events during late follow-up...


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Aterectomía Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Intervención Coronaria Percutánea/métodos , Quimioterapia , Angioplastia de Balón/métodos , Aspirina/administración & dosificación , Calcificación Vascular/terapia , Estudios Retrospectivos , Factores de Riesgo , Heparina/administración & dosificación
6.
Rev. bras. cardiol. invasiva ; 21(1): 18-22, jan.-mar. 2013. tab
Artículo en Portugués | LILACS | ID: lil-674483

RESUMEN

INTRODUÇÃO: A injeção de trombina guiada por ultrassom (IT) é uma opção para o tratamento de pseudoaneurisma da artéria femoral. No entanto, o resultado dessa técnica em pacientes com síndrome coronária aguda (SCA) pode ser comprometido pelo uso de medicações antitrombóticas. Também, o extravasamento de trombina para a circulação sistêmica pode causar aumento de eventos tromboembólicos. MÉTODOS: Foram selecionados todos os pacientes admitidos com SCA que apresentaram pseudoaneurisma da artéria femoral após procedimento percutâneo, tratados com IT, entre janeiro de 2007 e julho de 2011. Características clínicas e laboratoriais, resultado do tratamento e complicações foram avaliados. RESULTADOS: Analisamos 23 pacientes, com idade de 67,1 ± 14,2 anos, 60,9% eram do sexo feminino, com índice de massa corporal de 28,4 ± 4,7 kg/m², e 52,2% eram diabéticos. À apresentação, 87% tinham SCA sem supradesnivelamento do segmento ST e o restante, infarto do miocárdio com supradesnivelamento do segmento ST. Entre os pacientes avaliados, 70% foram submetidos a intervenção coronária percutânea. Todos os pacientes estavam em uso de ácido acetilsalicílico, 78,3% utilizaram inibidores da P2Y12 e 39,1%, inibidores da glicoproteína IIb/IIIa. A IT foi eficaz em ocluir o pseudoaneurisma em 100% dos casos (96,7% após a primeira injeção), sem embolia distal, infecção local ou necessidade de correção cirúrgica em nenhum caso. Não houve infarto, acidente vascular cerebral ou revascularização não-programada. Houve um óbito por choque cardiogênico, 22 dias após a IT, no segundo dia após cirurgia eletiva de revascularização miocárdica. CONCLUSÕES: O tratamento de pseudoaneurisma da artéria femoral com IT é um método seguro e eficaz em pacientes com SCA.


BACKGROUND: Ultrasound-guided thrombin injection (TI) is an option for the treatment of femoral artery pseudoaneurysm. Nevertheless, the result of this technique in patients with acute coronary syndrome (ACS) may be compromised by the use of antithrombotic drugs. In addition, thrombin extravasation to systemic circulation could potentially cause an increase in thromboembolic events. METHODS: Patients admitted with ACS who developed femoral artery pseudoaneurysm after a percutaneous procedure and treated by TI between January 2007 and July 2011 were included. Clinical and laboratory characteristics, treatment results and complications were evaluated. RESULTS: We evaluated 23 patients with mean age of 67.1 ± 14.2 years, 60.9% were women, with body mass index of 28.4 ± 4.7 kg/m² and 52.2% were diabetics. At presentation, 87% had non-ST elevation ACS and the remaining had ST elevation myocardial infarction. Of the evaluated patients, 70% were submitted to percutaneous coronary intervention. All patients were receiving aspirin, 78.3% used P2Y12 inhibitors and 39.1% used glycoprotein IIb/IIIa inhibitors. TI was successful in occluding the pseudoaneurysm in 100% of cases (96.7% after the first injection), without distal embolization, local infection or need of surgical correction. There were no cases of myocardial infarction, stroke or unscheduled revascularization. There was one death due to cardiogenic shock 22 days after TI, on the second post-operative day after an elective coronary artery bypass graft surgery. CONCLUSIONS: Treatment of femoral artery pseudoaneurysm by TI is a safe and effective procedure in patients with ACS.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Arteria Femoral/fisiopatología , Aneurisma Falso/fisiopatología , Aneurisma Falso/terapia , Síndrome Coronario Agudo/complicaciones , Síndrome Coronario Agudo/fisiopatología , Trombina/administración & dosificación , Cateterismo Cardíaco , Heparina/administración & dosificación , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria , Ultrasonografía Intervencional/métodos
7.
Rev. bras. cardiol. invasiva ; 21(3): 221-226, 2013. graf, tab
Artículo en Portugués | LILACS | ID: lil-690652

RESUMEN

INTRODUÇÃO: A valvuloplastia aórtica por cateter balão (VAB) é utilizada como estratégia paliativa em pacientes inelegíveis tanto para troca valvar cirúrgica quanto para implante valvar aórtico transcateter, ou como ponte para essas modalidades de tratamento. Não se sabe o impacto terapêutico da VAB quando realizada como medida de salvamento para pacientes em condições clínicas extremas (in extremis). MÉTODOS: Foram analisados pacientes com estenose aórtica grave de etiologia degenerativa submetidos à VAB entre julho de 2008 e janeiro de 2013. Os pacientes foram divididos entre o grupo in extremis (definido pela presença de duas ou mais das seguintes disfunções orgânicas: ventilação mecânica, instabilidade hemodinâmica, terapia renal dialítica, coagulopatia ou disfunção hepática graves) e o grupo controle, que incluiu os demais pacientes. RESULTADOS: Um total de 19 pacientes realizaram VAB no período. A condição clínica in extremis esteve presente em 42,1%. Os pacientes do grupo in extremis tiveram EUROSCORE II mais elevado (41,1 ± 24,7 vs. 15,9 ± 14,0; P = 0,01) e fração de ejeção do VE mais baixa que o grupo controle (33,9 ± 17,3% vs. 49,0 ± 12,5%; P = 0,04). Nenhum paciente do grupo in extremis sobreviveu ao período intra-hospitalar, enquanto que, no grupo controle, a mortalidade foi de 27,3% (P < 0,01). CONCLUSÕES: Para o tratamento de pacientes com estenose aórtica grave de etiologia degenerativa, a VAB tem resultado desfavorável quando indicada para pacientes com duas ou mais disfunções orgânicas, ou seja, em condição clínica in extremis.


BACKGROUND: Balloon aortic valvuloplasty (BAV) is used as a palliative strategy in patients who are not eligible for valve replacement surgery, transcatheter aortic valve implantation, or as a bridge to these treatment modalities. The impact of BAV as a salvage procedure for patients in extreme clinical conditions (in extremis) is unknown. METHODS: Patients with severe degenerative aortic stenosis undergoing BAV between July 2008 and January 2013 were evaluated. Patients were divided into the in-extremis group (defined by the presence of two or more of the following organ dysfunctions: mechanical ventilation, hemodynamic instability, dialysis, coagulopathy or severe hepatic dysfunction) and the control group, which included the remaining patients. RESULTS: A total of 19 patients underwent BAV. The clinical condition in-extremis was present in 42.1% of them. Patients from the in-extremis group had a higher EUROSCORE II (41.1 ± 24.7 vs. 15.9 ± 14.0; P = 0.001) and LV ejection fraction lower than the control group (33.9 ± 17.3% vs. 49.0 ± 12.5; P = 0.04). None of the patients in the in-extremis group survived past the hospitalization period, whereas the control group mortality was 27.3% (P < 0.01). CONCLUSIONS: BAV has an unfavorable result in patients with severe degenerative aortic stenosis with two or more organ dysfunctions, that is, patients in extremis.


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Implantación de Prótesis de Válvulas Cardíacas , Valvuloplastia con Balón/instrumentación , Análisis de Datos/análisis , Ecocardiografía/métodos , Factores de Riesgo
10.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;21(1): 68-74, jan.-mar. 2006. tab, graf
Artículo en Portugués | LILACS | ID: lil-431024

RESUMEN

OBJETIVO: Avaliar a presença de sintomas de depressão no pré-operatório, no pós-operatório imediato (POI) e pós-operatório tardio (POT) de pacientes com indicação eletiva de cirurgia de revascularização do miocárdio e seu impacto na morbidade pós-operatória imediata e tardia. MÉTODO: Cinqüenta e oito pacientes internados na Enfermaria de Cirurgia Cardíaca para realização de operação eletiva de revascularização do miocárdio responderam ao Inventário de Depressão de Beck, antes da operação (fase I), antes da alta hospitalar (fase II) e três meses após a alta (fase III). A média de idade dos pacientes foi 61,2 (34 a 78 anos; DP:10,1), 34 (58,6 por cento) eram homens, 31 (55,4 por cento) com infarto prévio, 35 (62,5 por cento) com fração de ejeção maior que 40 por cento e 19 (33 por cento) diabéticos. RESULTADOS: Doze (20,7 por cento) pacientes apresentaram sintomas de depressão na fase I, 13 (23,6 por cento), na II e 4 (9,8 por cento), na III. Dezoito (31,0 por cento) pacientes apresentaram complicações no POI, 17 (34,0 por cento), no POT. Complicações no POI ocorreram com maior freqüência em pacientes mais velhos (idade superior a 65 anos; p=0,003), com pelo menos três vasos revascularizados (p=0,001) e com depressão na fase I (p=0,011). Quando estas variáveis foram associadas às complicações presentes no POT, houve significância para o sexo feminino (p=0,006) e depressão na fase II (p=0,008). Pacientes do sexo feminino apresentaram mais sintomas de depressão durante a internação (p=0,04). CONCLUSAO: Idade superior a 65 anos, sexo feminino, pelo menos três vasos revascularizados e sintomas de depressão durante a internação mostraram-se associados a maior número de complicações no pós-operatório de cirurgia de revascularização do miocárdio. Pacientes submetidos à cirurgia de revascularização do miocárdio devem ser avaliados em relação à depressão e tratados se necessário, uma vez que esta pode estar associada a complicações no pós-operatório.


Asunto(s)
Masculino , Femenino , Adulto , Anciano , Humanos , Enfermedad Coronaria/psicología , Depresión/psicología , Complicaciones Posoperatorias , Factores de Riesgo , Revascularización Miocárdica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA