Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Lymphology ; 53(4): 204-211, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33721926

RESUMEN

Tissue dielectric constant (TDC) and skin firmness assessed via indentation force (FORCE) help quantify lymphedema and track changes. We sought to determine potential differences in these parameters dependent on arm circumferential locations. Thus, TDC and FORCE were measured in 40 healthy women at medial, anterior and lateral locations on forearm and biceps. In five other women with unilateral lymphedema (68.6±7.6 years), TDC was measured at corresponding circumferential forearm positions. Measurements were done in triplicate using compact noninvasive devices. Results for healthy women (23.8±2.7 years) showed forearm medial TDC values (26.7±2.2) were less than anterior (28.0±2.4) or lateral (28.0±2.5) positions (p<0.001). Lymphedema patients had elevated values but similar medialanterior- lateral patterns (33.7±8.0, 39.8±10.2 and 42.9±10.0). Biceps medial TDC values (24.1±2.2) were also less than either anterior (27.0±2.1) or lateral (28.2±3.3). Contrastingly, medial FORCE values at forearm and biceps were less than at anterior and lateral locations (p<0.001) and increased in the order of medialanterior- lateral on forearm (p<0.001). The present findings provide reference values for both TDC and FORCE of commonly measured arm sites with specificity as to circumferential variations. This observed variation indicates the need for care in locating measurement positions for tracking patients with lymphedema.


Asunto(s)
Antebrazo , Linfedema , Brazo , Impedancia Eléctrica , Femenino , Humanos , Linfedema/diagnóstico , Piel , Extremidad Superior
2.
J Cardiovasc Electrophysiol ; 11(9): 960-7, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11021465

RESUMEN

INTRODUCTION: After mitral valve (MV) surgery, preoperative atrial fibrillation (AF) often recurs while cardioversion therapy generally fails. Additional Cox maze surgery improves postoperative arrhythmia outcome, but the extensive nature of such an approach limits general appliance. We investigated the clinical outcome of a simplified, less extensive Cox maze procedure ("mini-maze") as adjunct to MV surgery. METHODS AND RESULTS: Thirteen patients with MV disease and preoperative AF were treated with combined surgery (group 1). Nine control patients without previous AF underwent isolated MV surgery (group 2). We retrospectively compared the results to findings in 23 patients with preoperative AF who had undergone isolated MV surgery (group 3). In group 1, mini-maze took an additional 46 minutes of perfusion time. One 75-year-old patient died of postoperative multiple organ failure. Seven patients showed spontaneously converting (within 2 months) postoperative AF. After 1 year, 82% were in sinus rhythm (SR). No sinus node dysfunction was observed. In group 2, all patients were in SR after 1 year. In group 3, only 53% were in SR after 1 year, despite serial cardioversion and antiarrhythmic drug therapy. Exercise tolerance and heart rate were comparable for groups 1 and 2. Left atrial function was present in all but one patient in group 1 and in all patients in group 2 (after MV reconstruction). CONCLUSION: Adding a relatively simple mini-maze to MV surgery improves arrhythmia outcome in patients with preoperative AF without introducing sinus node dysfunction or persistent absence of left atrial function. The results of this type of combined surgery are encouraging and deserve further attention.


Asunto(s)
Fibrilación Atrial/complicaciones , Válvula Mitral/cirugía , Anciano , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Procedimientos Quirúrgicos Cardíacos , Ecocardiografía , Cardioversión Eléctrica , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
3.
Eur J Heart Fail ; 2(2): 167-73, 2000 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10856730

RESUMEN

UNLABELLED: Experimental data have shown that rIL2 has negative inotropic properties. This has not been investigated in humans with normal left ventricular function. Seventeen consecutive renal cell carcinoma patients who received rIL2 therapy because of dissemination were analyzed before and after treatment with a low dose of rIL2 subcutaneously. Left ventricular ejection fraction (echocardiography), heart rate variability parameters (24 h electrocardiography), and TNF alpha, IL1 beta and nitric oxide metabolites (NO(x)) were measured. LVEF decreased from 54+/-7 to 50+/-6% (mean+/-S.D.; P=0.012), with a concomitant increase in heart rate from 87+/-13 to 94+/-13 beats/min (P=0.031). All frequency domain HRV parameters decreased: the total power from 18.0+/-7.9 to 14.0+/-5.0 ms (P=0.001), the low frequency from 10.3+/-5.4 to 8. 3+/-3.4 ms (P=0.001), and the high frequency from 6.3+/-2.6 to 4. 5+/-1.1 ms (P=0.001). There was no measurable effect on TNF alpha, IL1 beta concentrations. Plasma levels of nitrate (NO(x)) increased from 22.8+/-14.4 to 41.8+/-26.6 micromol/l (P=0.007). CONCLUSIONS: A low dose of rIL2 has a negative inotropic effect that may be mediated by increased NO concentrations. It also reduces sympathetic activity as reflected in HRV parameters.


Asunto(s)
Corazón/efectos de los fármacos , Interleucina-2/farmacología , Función Ventricular Izquierda/efectos de los fármacos , Adulto , Anciano , Sistema Nervioso Autónomo/fisiopatología , Carcinoma de Células Renales/fisiopatología , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Neoplasias Renales/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Proteínas Recombinantes/farmacología , Volumen Sistólico/efectos de los fármacos
4.
Hypertension ; 30(5): 1162-8, 1997 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9369271

RESUMEN

We investigated 24-hour ambulatory blood pressure and arterial distensibility, a marker of biophysical vessel wall properties, in 32 normoalbuminuric type I diabetic patients and 32 healthy control subjects on diets containing 50 mmol and 200 mmol sodium per day. The increase in daytime diastolic blood pressure from 50 to 200 mmol sodium was significantly higher in the diabetic patients than in the control subjects (2.3+/-4.9 versus 0.2+/-3.7 mm Hg, P<.05). On a high sodium regimen, femoral artery distensibility was decreased in the diabetic patients compared with the control subjects (19.2+/-7.6 versus 24.1+/-9.3 10[-3]/kPa, P<.05). Angiotensin-converting enzyme inhibition in the diabetic patients on a high sodium diet decreased daytime diastolic blood pressure and increased femoral artery distensibility. The blood pressure decrease in response to angiotensin-converting enzyme inhibition correlated significantly with the blood pressure increase to sodium (for 24-hour systolic and diastolic blood pressure, r=.72, P<.001 and r=.76, P<.001). In addition, we found that in the diabetic patients on a high sodium diet, the renal blood flow response to exogenous angiotensin II was not bimodally distributed, as is the case in essential hypertension, in which a subgroup of the patients are characterized by sodium sensitivity of the blood pressure and an abnormal renal blood flow response to exogenous angiotensin II ("nonmodulator phenotype"). These results show that blood pressure in insulindependent diabetes mellitus is sodium sensitive, but that this is not related to the nonmodulator phenotype, and suggest that in IDDM a relatively high sodium intake may be a factor that predisposes to the development of diabetic vascular disease.


Asunto(s)
Presión Sanguínea/fisiología , Diabetes Mellitus Tipo 1/fisiopatología , Dieta Hiposódica , Arteria Femoral/fisiopatología , Adulto , Inhibidores de la Enzima Convertidora de Angiotensina/farmacología , Adaptabilidad , Diástole , Femenino , Tasa de Filtración Glomerular/fisiología , Humanos , Masculino , Valores de Referencia , Circulación Renal/fisiología
5.
Am J Cardiol ; 79(3): 334-8, 1997 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-9036754

RESUMEN

The purpose of this prospective multicenter study of 350 consecutive patients who were accepted for mitral valve surgery because of severe regurgitation, was to assess the value of preoperative transthoracic and transesophageal echocardiography in predicting the surgical strategy in severe mitral regurgitation: repair or replacement. The cardiologist predicted the surgical strategy on the basis of the echocardiographic examination, according to predefined guidelines for repair and replacement. The predicted strategy and motivation thereof were compared with the surgical findings and procedure that was performed. Agreement on the basis of transthoracic echocardiography was reached in 86% of the repair patients and on the basis of transesophageal echocardiography in 89%. Agreement on the basis of transthoracic echocardiography was reached in 74% of the replacement patients and on the basis of transesophageal echocardiography in 75%. This study underlines the potential role of echocardiography in predicting the surgical procedure to be applied, provided that both surgeon and cardiologist use the same nomenclature and that the guidelines for replacement/repair are adhered to. Both transthoracic and transesophageal echocardiography appear to be equally accurate in predicting the optimal surgical procedure in this respect.


Asunto(s)
Ecocardiografía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Ecocardiografía Transesofágica , Humanos , Países Bajos , Valor Predictivo de las Pruebas , Estudios Prospectivos
6.
Am J Cardiol ; 79(1): 108-11, 1997 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-9024755

RESUMEN

In postinfarction patients, only biplane echocardiographic evaluation of left ventricular ejection fraction (EF) accurately predicts radionuclide EF > or <0.35, 0.40, and 0.45. A wall motion scoring system that does not account for hyperkinesia of healthy myocardium may be used to discriminate between radionuclide EF > or <0.40 or 0.45, but lacks accuracy for 0.35.


Asunto(s)
Ecocardiografía , Corazón/diagnóstico por imagen , Infarto del Miocardio/fisiopatología , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico por imagen , Cintigrafía , Disfunción Ventricular Izquierda/complicaciones
7.
Am J Cardiol ; 78(10): 1132-9, 1996 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-8914877

RESUMEN

This study was designed to examine the accuracy of multiplane transesophageal echocardiography (TEE) color Doppler measurements in comparison to monoplane or biplane measurements in estimating the severity of mitral regurgitation (MR). Multiplane TEE potentially increases diagnostic accuracy of transesophageal examinations; it is unknown if multiplane is more accurate in assessing the severity of MR than monoplane or biplane TEE. Left ventricular cineangiograms of 91 patients with MR (40 no or mild, 30 moderate, and 21 severe) were compared with systolic pulmonary venous flow reversal and transesophageal color Doppler measurements: jet area and length in the transverse and longitudinal plane, maximal and average of those 2 planes (biplane), and maximal and average of 11 different planes (multiplane). Flow reversal (16 patients) identified severe MR with a specificity of 96% and a sensitivity of 62%; these were 96% and only 10% to 43%, respectively, for color Doppler measurements. In the absence of flow reversal, multiplane maximal jet area predicted severe MR with a sensitivity of 88% and a specificity of 75%, which were 85% and 76%, respectively, for no or mild MR; this did not differ significantly from results obtained by monoplane or biplane measurements. Color Doppler measurements of eccentric jets were not reliable for identification of severe MR. Systolic pulmonary venous flow reversal identifies 2 of 3 patients with severe MR with a high accuracy. In patients without flow reversal, multiplane color Doppler TEE is very capable of assessing MR severity, but biplane and monoplane TEE are equally accurate.


Asunto(s)
Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Cineangiografía , Ecocardiografía Doppler en Color , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Flujometría por Láser-Doppler , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Curva ROC , Flujo Sanguíneo Regional , Sensibilidad y Especificidad
8.
J Cardiothorac Vasc Anesth ; 10(6): 748-55, 1996 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-8910154

RESUMEN

OBJECTIVE: To determine the value of biplane transesophageal echocardiography in the assessment of severity of mitral regurgitation compared with left ventricular angiography. DESIGN: Prospective study of consecutive patients. SETTING: Two university hospitals, one community hospital. PARTICIPANTS: Thirty-seven patients with angiographically proven mitral regurgitation. INTERVENTION: Transthoracic and biplane transesophageal echocardiography. In 19 patients, transesophageal echocardiography was performed during general anesthesia. MEASUREMENTS AND MAIN RESULTS: The largest mitral regurgitation jet area and longest jet as obtained with Doppler color-flow mapping from transthoracic and biplane transesophageal echocardiography and pulsed-Doppler pulmonary venous flow characteristics. Sensitivity and 100-minus-specificity were plotted to constitute receiver operating characteristics (ROC) curves. Areas under ROC curve for transverse, longitudinal, and biplane jet area were 0.77, 0.75, and 0.81, and for jet length, 0.82, 0.84, and 0.88, respectively; this was for biplane jet area in conscious patients; 0.99 compared with 0.72 in anesthetized patients (p < 0.05). CONCLUSIONS: Biplane measurements identified severe mitral regurgitation slightly more reliably than the transverse or longitudinal measurements alone. In conscious patients, jet area was an excellent test for estimating severity of mitral regurgitation. In anesthetized patients, a combination of biplane jet area and length and of systolic pulmonary venous flow reversal accurately predicted angiographic severity of mitral regurgitation. In anesthetized patients, the optimal cut-off value for jet area to distinguish between moderate and severe mitral regurgitation was lower than in conscious patients. In the total population, regardless of hemodynamic and technical variations, a combination of biplane jet area and length and of systolic pulmonary venous flow reversal accurately predicted the severity of mitral regurgitation.


Asunto(s)
Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Hemodinámica , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
9.
Am J Cardiol ; 78(4): 444-50, 1996 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-8752191

RESUMEN

We evaluated the value of color and pulsed Doppler transesophageal echocardiographic parameters and of V waves in estimating the severity of mitral regurgitation (MR) in 62 consecutive patients (38 men and 24 women, aged 39 to 80 years) with angiographically proven chronic pure MR (15 grade I/II, 47 grade III/IV). Twenty patients were examined before cardiac surgery under general anesthesia. Sensitivity, specificity, and positive and negative predictive values of systolic pulmonary venous flow reversal for the presence of grade III/IV MR were 87%, 93%, 98%, and 64%, respectively, these were for jet areas > or = 8.0 cm2--66%, 100%, 100%, and 48%, for jet lengths > or = 50 mm--70%, 87%, 94%, and 48%, for enlarged V waves--86%, 38%, 83%, and 43%, and for either flow reversal or a jet area > or = 8.0 cm2--96%, 93%, 98%, and 88%. We conclude that a combination of measurements improved the negative predictive value considerably, which is of importance in a population with a high pretest probability of severe MR. Enlarged V waves are not reliable in predicting severe MR. The optimal cutoff value for jet area and jet length was lower in anesthesized patients than in conscious patients; in anesthesized patients, sensitivity, specificity, and positive and negative predictive values of jet area > or = 5.0 CM2 for grade III/IV MR were 67%, 100%, 100%, and 50%, respectively; these were 87%, 100%, 100%, and 71% for flow reversal. Because the results of mitral repair are often evaluated with transesophageal echocardiography during surgery, our findings have clinical implications for evaluation of severe MR in anesthesized patients: pulmonary venous flow direction is the first-choice measure; jet area can be used when a low cutoff point is chosen.


Asunto(s)
Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Venas Pulmonares/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Anestesia General , Angiografía , Gasto Cardíaco , Enfermedad Crónica , Cinerradiografía , Estado de Conciencia , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Probabilidad , Presión Esfenoidal Pulmonar , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Sístole
10.
Am J Cardiol ; 77(9): 728-33, 1996 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-8651124

RESUMEN

This prospective study was conducted to ascertain whether echocardiographic evaluation could provide more insight into the genesis of mitral regurgitation (MR) before surgery. All patients underwent preoperative transthoracic and transesophageal echocardiography. Nine centers participated in the ESMIR (Echocardiographic Selection of patients for MItral valve Reconstruction) study and 350 patients were included. Compared with surgical findings, the percentage of functional abnormalities correctly predicted by both echo modalities was highest in patients with increased leaflet mobility (83% for transthoracic and 86% transesophageal echocardiography). In contrast, in normal leaflet mobility, the prediction was better by transthoracic than by transesophageal echocardiography (75% vs 64%). In patients with restricted leaflet mobility, the predictive value of both techniques was similar. The diagnostic yield of anatomic abnormalities of both echo techniques was similar, except for chordal rupture; a sensitivity by transesophageal echocardiography of 79% and by transthoracic echocardiography of 57% (p < 0.001). In general, the sensitivity of each echo technique for detecting anatomic abnormalities was <70%, except for annular dilatation, leaflet thickening, and chordal rupture. At surgery, the prevailing functional condition was increased leaflet mobility (42%). The conclusion is that both echo techniques provide adequate information regarding the functional condition of the mitral valve apparatus, not withstanding limitations in assessing anatomic details. Transthoracic echocardiography appears to be sufficient for preoperative evaluation of MR.


Asunto(s)
Ecocardiografía Doppler , Ecocardiografía Transesofágica , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cuerdas Tendinosas/diagnóstico por imagen , Cuerdas Tendinosas/fisiopatología , Dilatación Patológica , Femenino , Predicción , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/fisiopatología , Cuidados Preoperatorios , Estudios Prospectivos , Rotura Espontánea , Sensibilidad y Especificidad
11.
Am J Cardiol ; 75(7): 489-93, 1995 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-7863995

RESUMEN

To determine the additional diagnostic value of biplane transesophageal echocardiography (TEE) in patients undergoing mitral valve surgery, we studied 48 patients with severe mitral regurgitation. Transesophageal echocardiographic video recordings were reorganized in separate transverse and longitudinal sections to allow independent evaluation. Mechanism of mitral regurgitation and anatomic abnormalities of the mitral valve were assessed by all 3 transesophageal echocardiographic modalities and were related to surgical findings. Biplane TEE detected increased leaflet mobility with a sensitivity of 91% and a specificity of 84%, and restricted leaflet mobility with a sensitivity of 100% and a specificity of 97%. Biplane TEE was accurate in the diagnosis of most of the anatomic abnormalities associated with these mechanisms. However, the sensitivity for detecting subvalvular abnormalities (including papillary muscle abnormalities) was poor, and measurement of the annular diameter had a poor correlation with annular dilatation. Although the yield of biplane TEE was better than either transverse or longitudinal TEE alone, the differences did not reach statistical significance, because of the size of the patient group. The surgical procedure (either valve repair or replacement) was correctly predicted with transverse TEE in 71%, with longitudinal TEE in 69%, and with biplane TEE in 79% of the patients. All 3 transesophageal echocardiographic modalities are very capable of assessing the anatomic abnormalities and mechanism of mitral regurgitation, as well as predicting the feasibility of valve repair.


Asunto(s)
Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
12.
Hoppe Seylers Z Physiol Chem ; 363(3): 305-15, 1982 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-6122635

RESUMEN

A simple and rapid procedure is described for the separation of the human leucocyte enzymes alanine aminopeptidase, cathepsin G, collagenase, elastase and myeloperoxidase. The enzymes are prepared from leucocytes, obtained from buffy coat, by repeated extraction with buffer A(1 M salt concentration). The pooled extracts are successively subjected to batch adsorption on concanavalin A-Sepharose, gel filtration on Sephacryl S-300, affinity chromatography on collagen-Sepharose 4-B, batch adsorption on CM-Sephadex C-50 and adsorption chromatography on hydroxyapatite. The yields of the isolated enzymes of a typical preparation are 47% alanine aminopeptidase, 9% cathepsin G, 90% latent and active collagenase, 23% elastase and approximately 100% myeloperoxidase with respect to the pooled extracts. The cathepsin G, collagenase and elastase preparations are essentially free from other proteolytic enzymes and may be used without further purifications.


Asunto(s)
Aminopeptidasas/sangre , Catepsinas/sangre , Leucocitos/enzimología , Colagenasa Microbiana/sangre , Elastasa Pancreática/sangre , Peroxidasa/sangre , Peroxidasas/sangre , Aminopeptidasas/aislamiento & purificación , Antígenos CD13 , Catepsina G , Catepsinas/aislamiento & purificación , Humanos , Cinética , Colagenasa Microbiana/aislamiento & purificación , Elastasa Pancreática/aislamiento & purificación , Peroxidasa/aislamiento & purificación , Serina Endopeptidasas
13.
Hosp Community Psychiatry ; 30(9): 625-7, 1979 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-112024

RESUMEN

In order to interest businesses in buying mental health services for their employees, professionals must be able to speak the businessman's language and market their product--mental health services. They must emphasize the cost-effectiveness of mental health care and explain how the business can benefit from including such services in the company's benefits package. The authors describe some concepts and strategies they found helpful when they ventured into the business community to "sell" the services of their community mental health center. They discuss such factors as the need to present a polished, professional image and to gear services to the needs of the particular employer and his employees.


Asunto(s)
Planes de Asistencia Médica para Empleados/economía , Recursos en Salud , Seguro de Salud/economía , Comercialización de los Servicios de Salud , Servicios de Salud Mental/economía , Análisis Costo-Beneficio , Eficiencia , Humanos , Industrias , Sindicatos , Pennsylvania
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA