1.
J Thorac Cardiovasc Surg ; 147(1): 397-401, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24071469

RESUMEN

OBJECTIVE: The modified Blalock-Taussig shunt is the most commonly used palliative procedure for infants with ductal-dependent pulmonary circulation. Recently, catheter-based stenting of the ductus arteriosus has been used by some centers to avoid surgical shunt placement. We evaluated the durability and safety of ductal stenting as an alternative to the modified Blalock-Taussig shunt. METHODS: A single-institution, retrospective review of patients undergoing modified Blalock-Taussig shunt versus ductal stenting was performed. Survival, procedural complications, and freedom from reintervention were the primary outcome variables. RESULTS: A total of 42 shunted and 13 stented patients with similar age and weight were identified. Survival to second-stage palliation, definitive repair, or 12 months was similar between the 2 groups (88% vs 85%; P = .742). The incidence of surgical or catheter-based reintervention to maintain adequate pulmonary blood flow was 26% in the shunted patients and 25% in the stented patients (P = 1.000). Three shunted patients (7%) required intervention to address contralateral pulmonary artery stenosis and 3 (7%) required surgical reintervention to address nonpulmonary blood flow-related complications. The need for ipsilateral or juxtaductal pulmonary artery intervention at, or subsequent to, second-stage palliation or definitive repair was similar between the 2 groups. CONCLUSIONS: Freedom from reintervention to maintain adequate pulmonary blood flow was similar between infants undergoing modified Blalock-Taussig shunt or ductal stenting as an initial palliative procedure. However, a greater percentage of shunted patients experienced procedure-related complications and distal branch pulmonary artery stenosis. Palliative ductal stenting appears to be a safe and effective alternative to modified Blalock-Taussig in selected infants.


Asunto(s)
Procedimiento de Blalock-Taussing , Cateterismo Cardíaco/instrumentación , Conducto Arterial/fisiopatología , Cardiopatías Congénitas/terapia , Cuidados Paliativos/métodos , Circulación Pulmonar , Stents , Procedimiento de Blalock-Taussing/efectos adversos , Procedimiento de Blalock-Taussing/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/mortalidad , Cardiopatías Congénitas/fisiopatología , Mortalidad Hospitalaria , Humanos , Lactante , Recién Nacido , Estimación de Kaplan-Meier , Selección de Paciente , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
2.
Pediatr Cardiol ; 32(6): 754-8, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21448617

RESUMEN

The development of tachycardia-induced cardiomyopathy (TIC) is related to the rate and duration of supraventricular tachycardia (SVT). Infants may be more susceptible to TIC because early symptoms might be unrecognized. Extracorporeal membrane oxygenation (ECMO) may improve outcome in patients with SVT and TIC; however, clinical predictors of infants who require ECMO support have not been determined. The purpose of this study was to identify predictors of the need for ECMO in infants with SVT and TIC. Sixteen infants <6 months of age who experienced resolution of TIC following control of arrhythmia were identified. Three patients (19%) required ECMO support. Comparisons were made between patients who required ECMO and those who did not. The groups were similar with respect to age at presentation, type of SVT, rate of SVT, and degree of ventricular dysfunction. However, patients requiring ECMO had increased median M-mode-derived left ventricular end diastolic dimension (LVED) z-score when compared to the medically managed patents (+2.8 vs. 0.0, P = 0.009). No patient in the medically managed group had an LVED z-score >2.3. Infants presenting with SVT and TIC with LVED z-score >2 are at increased risk for requiring ECMO support and early use of ECMO should be considered.


Asunto(s)
Cardiomiopatías/terapia , Oxigenación por Membrana Extracorpórea/métodos , Taquicardia Supraventricular/complicaciones , Cardiomiopatías/etiología , Femenino , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido , Masculino , Pronóstico , Estudios Retrospectivos , Taquicardia Supraventricular/terapia , Resultado del Tratamiento