Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
2.
Artículo en Inglés | MEDLINE | ID: mdl-39115503

RESUMEN

In at least one-half of the patients with angina or ischemia and nonobstructive coronary arteries undergoing coronary function testing, coronary artery spasm (CAS) is detected. CAS is associated with an adverse prognosis regarding recurrent complaints and ischemic events. Current treatment options are mainly focused on the complaints, not on the underlying pathophysiological process. In this review we discuss available evidence regarding the presence, amount, and morphology of atherosclerosis in CAS patients. The reviewed evidence confirmed that atherosclerosis and vulnerable plaque characteristics are often detected in patients with CAS. The amount of atherosclerosis is higher in patients with focal CAS compared with patients with diffuse CAS. Severity of atherosclerosis is associated with the presence of CAS and the prognosis in CAS patients with atherosclerotic stenosis is worse. Therefore, CAS patients with atherosclerosis might benefit from targeted atherosclerotic treatment. Longitudinal studies are needed to elucidate the exact relation between atherosclerosis and CAS.

3.
Clin Res Cardiol ; 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38958753

RESUMEN

INTRODUCTION: Drug-coated balloon (DCB) is an established treatment option for in-stent restenosis and small vessel, de novo, coronary artery disease (CAD). Although the use of this tool is increasing in everyday practice, data regarding performance in the treatment of de novo, large vessel CAD (LV-CAD) is still lacking. A systematic review and meta-analysis were conducted to evaluate the efficacy and safety of DCB versus drug-eluting stent (DES) in this setting. METHODS: A comprehensive literature search was performed including Medline, Embase, and Cochrane electronic databases up to January 24, 2024, for studies which compared the efficacy and safety of DCB versus DES in the treatment of de novo lesions in large vessels (≥ 2.5 mm), reporting at least one clinical outcome of interest (PROSPERO ID: CRD42023470417). The analyzed outcomes were cardiovascular death (CVD), myocardial infarction (MI), target lesion revascularization (TLR), all-cause death (ACD), and late lumen loss (LLL) at follow-up. The effect size was estimated using a random effects model as risk ratio (RR) and mean difference (MD) and relative 95% confidence interval (CI). RESULTS: A total of 13 studies (6 randomized controlled trials and 7 observational studies) involving 2888 patients (DCB n = 1334; DES n = 1533) with de novo LV-CAD were included in this meta-analysis following our inclusion criteria. No differences were observed between DCB and DES in terms of CVD (RR 0.49; 95% CI [0.23-1.03]; p = 0.06), MI (RR 0.48; 95% CI [0.16-1.45]; p = 0.89), TLR (RR 0.73; 95% CI [0.40-1.34]; p = 0.32), ACD (RR 0.78; 95% CI [0.57-1.07]; p = 0.12), and LLL (MD - 0.14; 95% CI [- 0.30 to 0.02]; p = 0.10) at follow-up. DES proved a higher mean acute gain versus DCB [1.94 (1.73, 2.14) vs 1.31 (1.02, 1.60); p = 0.0006]. CONCLUSION: Our meta-analysis showed that DCB PCI might provide a promising option for the management of selected, de novo LV-CAD compared to DES. However, more focused RCTs are needed to further prove the benefits of a "metal-free" strategy in this subset of CAD.

4.
Expert Rev Cardiovasc Ther ; 22(7): 325-337, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38970466

RESUMEN

INTRODUCTION: Over the past two decades, transcatheter aortic valve replacement (TAVR) has expanded its application across all surgical risk levels, including low-risk patients, where, due to longer life expectancy, reducing common pitfalls of TAVR is essential. To address these needs, many technological advancements have been developed. Myval and the new generation Myval Octacor (Meril Life Sciences Pvt. Ltd) are novel balloon-expandable (BE) transcatheter heart valve (THV) systems designed for the treatment of severe aortic stenosis. AREAS COVERED: This review aims to illustrate the design features of these novel THVs and the main evidence from available studies. Furthermore, we provide evidence of these THVs' performance in challenging scenarios such as extra-large aortic annuli, bicuspid aortic valves, and valve-in-valve/valve-in-ring procedures. EXPERT OPINION: Myval and Myval Octacor have demonstrated comparable early safety and clinical efficacy to the leading contemporary THVs, exhibiting remarkably low rates of moderate to severe paravalvular leak (PVL) and permanent pacemaker implantation (PPI). The wide range of sizes offered by the Myval family may minimize the risk of under-/oversizing, potentially explaining the lower rates of the aforementioned phenomena. Moreover, the presence of both internal skirt and external reinforced cuff may also explain the low rate of moderate to severe PVL.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen
5.
J Clin Med ; 13(12)2024 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-38930050

RESUMEN

Background: The optimal timing to perform percutaneous coronary interventions (PCIs) in patients undergoing transcatheter aortic valve replacement (TAVR) is not well established. In this meta-analysis, we aimed to compare the outcomes of patients undergoing PCI before versus after TAVR. Methods: A comprehensive literature search was performed including Medline, Embase, and Cochrane electronic databases up to 5 April 2024 for studies that compared PCI before and after TAVR reporting at least one clinical outcome of interest (PROSPERO ID: CRD42023470417). The analyzed outcomes were mortality, stroke, and myocardial infarction (MI) at follow-up. Results: A total of 3 studies involving 1531 patients (pre-TAVR PCI n = 1240; post-TAVR PCI n = 291) were included in this meta-analysis following our inclusion criteria. Mortality was higher in the pre-TAVR PCI group (OR: 2.48; 95% CI: 1.19-5.20; p = 0.02). No differences were found between PCI before and after TAVR for the risk of stroke (OR: 3.58; 95% CI: 0.70-18.15; p = 0.12) and MI (OR: 0.66; 95% CI: 0.30-1.42; p = 0.29). Conclusions: This meta-analysis showed in patients with stable CAD undergoing TAVR that PCI after TAVR is associated with lower mortality compared with PCI before TAVR.

7.
Int J Cardiol ; 400: 131701, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38168557

RESUMEN

BACKGROUND: The new balloon-expandable (BE) Myval transcatheter heart valves (THV) has shown promising early results with low paravalvular leak (PVL) and permanent pacemaker implantation (PPI) rates. Limited data are available regarding its long-term performance. We aimed to compare the 2-year clinical and echocardiographic outcomes of transcatheter aortic valve replacement (TAVR) using the self-expanding (SE) Evolut R and the BE Myval THVs. METHODS: The EVAL study included 166 patients with severe aortic valve stenosis who underwent TAVR either with SE Evolut R (n = 108) or BE Myval (n = 58) THV. Primary objectives include comparison on clinical efficacy (freedom from all-cause mortality, stroke, and cardiovascular hospitalization), echocardiographic performance and PPI rates between the two THVs. RESULTS: At 2-year the BE Myval group showed higher clinical efficacy (86% vs. 66%,HR:2.62, 95%CI 2.2-5.1;p = 0.006), with fewer cardiac hospitalizations (3.4% vs. 13.9%,p = 0.03). No significant differences in all-cause mortality, cardiovascular mortality, or stroke rates were observed. The proportion of patients with ≥moderate PVL was significantly lower in the BE Myval compared to the SE Evolut R group (4%vs. 22%,p = 0.008). The mean transvalvular gradient was significantly higher in the SE group compared to the BE group (9.5 ± 4.3 vs. 6.9 ± 2.2 mmHg,p < 0.001), however there was no difference in the percentage of patients with a mean gradient ≥20 mmHg between the two groups. CONCLUSIONS: Both THVs offer similar 2-year clinical outcomes. The BE Myval THV demonstrated advantages with higher clinical efficacy and lower PVL incidence. Longer follow-up and randomized trials are needed to validate these results and assess Myval's sustained performance and durability.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Diseño de Prótesis , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Accidente Cerebrovascular/cirugía
8.
AsiaIntervention ; 9(2): 101-102, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37736209
9.
J Clin Med ; 12(15)2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37568374

RESUMEN

Percutaneous treatment of the left main coronary artery is one of the most challenging scenarios in interventional cardiology, due to the large portion of myocardium at risk the technical complexity of treating a complex bifurcation with large branches. Our aim is to provide un updated overview of the current indications for percutaneous treatment of the left main, the different techniques and the rationale underlying the choice for provisional versus upfront two-stent strategies, intravascular imaging and physiology guidance in the management of left main disease, and the role of mechanical support devices in complex high-risk PCI.

10.
Int J Cardiol ; 389: 131236, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37532153

RESUMEN

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Sistema de Registros
12.
Eur Heart J Suppl ; 25(Suppl C): C79-C83, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37125288

RESUMEN

True coronary bifurcation lesions (CBL) represent a challenging scenario for percutaneous coronary interventions (PCI), and are associated with a higher risk of target lesion failure (TLF), particularly when two stents are implanted. A hybrid strategy combining a drug-eluting stent (DES) in the main branch, and a drug-coated balloon in the side branch may improve outcomes by reducing the total stent length while maintaining an effective anti-prolipherative action. In this sub-study of the HYPER trial, 50 patients with true CBL were treated with a hybrid strategy: procedural success was 96%, one case of peri-procedural myocardial infarction and one case of TLF (in a DES-treated segment) at 1 year were reported. This study suggests that such a hybrid strategy may be a safe and effective option for true CBL PCI, and warrants additional investigations to compare outcomes with standard of care strategies.

14.
Eur Eat Disord Rev ; 31(1): 46-64, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36367345

RESUMEN

BACKGROUND: Sexual orientation is usually developed during the adolescence, which coincides with the eating disorders peak onset. This paper aims to explore existing literature to identify whether there is an association between sexual orientation and eating disorder-related eating behaviours (EDrEBs) in this age-group. METHODS: This review was based on the PRISMA guidelines, covering the published articles between 1990 and 2021. A meta-analysis of the proportion of sexual orientation and the adjusted odds ratio (OR) with 95% confident intervals was reported. RESULTS: Ten studies (412,601 participants) were included in this review. The results demonstrated adolescents identified as minority sexual orientation, particularly homosexual males were with higher OR of EDrEBs, as follows: Homosexual (binge eating: M = 7.20, F = 2.14; purging: M = 5.40, F = 2.41; diet pills use: M = 3.50, F = 2.59; dieting: M = 3.10, F = 1.75); Bisexual (binge eating: M = 4.60, F = 2.26; purging: M = 4.44, F = 2.37; diet pills use: M = 3.42, F = 2.30; dieting: M = 2.36, F = 1.86). CONCLUSIONS: Adolescents who were of a minority sexual orientation were more vulnerable to EDrEBs than their heterosexual peers. Healthcare professionals and sexual minority communities should be primed to facilitate earlier recognition and access to services in these vulnerable groups.


Asunto(s)
Trastornos de Alimentación y de la Ingestión de Alimentos , Conducta Sexual , Femenino , Humanos , Masculino , Adolescente , Trastornos de Alimentación y de la Ingestión de Alimentos/epidemiología , Conducta Alimentaria
16.
EuroIntervention ; 18(5): e397-e404, 2022 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-35082112

RESUMEN

BACKGROUND: An association between atherosclerosis and coronary vasospasm has previously been suggested. However, to date, no conclusive data on the whole spectrum of these disorders have been published. AIMS: This study aimed to define specific morphological features of atherosclerosis in patients with angina and no obstructive coronary artery disease (ANOCA) due to coronary vasospasm. METHODS: From February 2019 to January 2020, we enrolled 75 patients referred to our laboratory for a coronary function test (CFT) due to ANOCA and suspected coronary vasomotor dysfunction. The CFT consisted of an acetylcholine test and a physiology assessment with hyperaemic indexes using adenosine. Patients were divided into two groups according to the presence or absence of coronary vasospasm triggered by acetylcholine (ACH+ and ACH-, respectively). In addition, optical coherence tomography (OCT) was performed to assess the lipid index (LI), a surrogate for lipid area, and the prevalence of markers of plaque vulnerability. RESULTS: ACH+ patients had a higher LI than ACH- patients (LI: 819.85 [460.95-2489.03] vs 269.95 [243.50-878.05], respectively, p=0.03), and a higher prevalence of vulnerable plaques (66% vs 38%, p=0.04). Moreover, ACH+ patients showed a higher prevalence of neovascularisation compared to ACH- subjects (37% vs 6%, p=0.02) and a trend towards a higher prevalence of all individual markers, in particular thin-cap fibroatheroma (20% vs 0%, p=0.06). No differences were detected between patterns of coronary vasospasm. CONCLUSIONS: The presence of coronary vasospasm, regardless of its phenotype, is associated with higher lipid burden, plaque vulnerability and neovascularisation.


Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Vasoespasmo Coronario , Placa Aterosclerótica , Acetilcolina , Angina de Pecho , Biomarcadores , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasoespasmo Coronario/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Humanos , Lípidos , Placa Aterosclerótica/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos
17.
Catheter Cardiovasc Interv ; 100 Suppl 1: S25-S35, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36661369

RESUMEN

BACKGROUND: Uncovered struts are a determinant of stent failure. The impact of plaque composition and procedural factors on the occurrence, evolution, and outcomes of uncovered struts in a high-risk setting has not been investigated. OBJECTIVE: To investigate the determinants and long-term clinical impact of largely uncovered struts (LUS) in thin-struts drug-eluting stents (DES) implanted in complex lesions by intracoronary optical coherence tomography (OCT). METHODS: Ninety patients with multivessel disease undergoing staged complete revascularization were randomly assigned to bioabsorbable or durable polymer DES. OCT were serially performed during the index procedure, at 3- and 18-month follow-up, and analyzed by an independent core lab. Struts were defined uncovered by OCT if no tissue was visible above the struts. LUS were defined as ≥30% of uncovered struts at 3-month follow-up. Clinical outcomes were the occurrence of target vessel failure (TVF) and major adverse cardiac and cerebrovascular events (MACCE) at 5-year follow-up. RESULTS: LUS occurred in 31 patients (34.4%) regardless of stent platform. At 5 years, no differences were observed in the rate of TVF (12.7% vs. 13.4%; p = 0.91) and MACCE (23.9% vs. 24.9%; p = 0.88) between the two groups. At multivariate logistic regression, plaque rupture, mean lumen diameter, proximal reference vessel area, and maximum stent deployment pressure were independent predictors of LUS. CONCLUSIONS: LUS are a frequent finding in complex coronary lesions treated with thin-struts DES, especially in the presence of plaque rupture. However, in this study, no significant safety signal related to LUS emerged in long-term follow-up.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Placa Aterosclerótica , Humanos , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento , Diseño de Prótesis , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos
18.
Cardiovasc Revasc Med ; 35: 129-138, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33863660

RESUMEN

BACKGROUND: Cytokine storm-related hypercoagulation may be important in the pathogenesis of stent thrombosis in patients with SARS-CoV-2. Whether stent polymers behave differently under such conditions has never been explored. METHODS: Fluorinated polymer-nanocoated and uncoated COBRA stents (CeloNova), BioLinx-polymer-coated Resolute Onyx stents (Medtronic), and Synergy stents (Boston Scientific), which are abluminally coated with a bioabsorbable polymer, were exposed to human blood from healthy donors which was supplemented with 400 pg/mL IL-6 and 100 pg/mL TNF-α, similar to what is seen in cytokine storm caused by SARS-CoV-2. Platelet adhesion and neutrophil activation, assessed by immunofluorescence, were compared under cytokine storm and control conditions (untreated blood) (n = 4 experimental runs). RESULTS: Platelet adhesion values, defined as %platelet-covered area x staining intensity, were significantly lower in coated and uncoated COBRA and in Resolute Onyx than in Synergy under control conditions (1.28 × 107 ± 0.43 × 107 vs. 2.92 × 107 ± 0.49 × 107 vs. 3.57 × 107 ± 0.73 × 107 vs. 9.94 × 107 ± 0.99 × 107; p ≤0.0001). In cytokine storm, platelet adhesion values remained low in coated COBRA-PzF (1.78 × 107 ± 0.38 × 107) compared to all other devices (uncoated COBRA: 5.92 × 107 ± 0.96 × 107; Resolute Onyx: 7.27 × 107 ± 1.82 × 107; Synergy: 11.28 × 107 ± 1.08 × 107; p ≤ 0.0001). Although cytokine storm conditions significantly increased neutrophil activation in all stents, it was significantly less in coated and uncoated COBRA, and in Resolute Onyx than in Synergy. CONCLUSIONS: Blood-biomaterials interactions may determine the thrombogenic potential of stents. Under simulated cytokine storm conditions, fluoropolymer-coated stents showed the most favorable anti-thrombogenic and anti-inflammatory properties.


Asunto(s)
COVID-19 , Síndrome de Liberación de Citoquinas , Humanos , Diseño de Prótesis , SARS-CoV-2 , Stents
20.
J Hypertens ; 39(9): 1742-1767, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34269334

RESUMEN

The present paper provides an update of previous recommendations on Home Blood Pressure Monitoring from the European Society of Hypertension (ESH) Working Group on Blood Pressure Monitoring and Cardiovascular Variability sequentially published in years 2000, 2008 and 2010. This update has taken into account new evidence in this field, including a recent statement by the American Heart association, as well as technological developments, which have occurred over the past 20 years. The present document has been developed by the same ESH Working Group with inputs from an international team of experts, and has been endorsed by the ESH.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , Hipertensión , Presión Sanguínea , Determinación de la Presión Sanguínea , Humanos , Hipertensión/diagnóstico , Sociedades Médicas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA