Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 31(11): 1443-55, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18950302

RESUMEN

BACKGROUND: Optimizing dual-chamber pacing to prevent recurrences of atrial tachyarrhythmias (AT) in sinus node dysfunction is still debated. Despite the large number of studies, efficacy of sophisticated preventive algorithms has never been proven. It is not clear whether this is due to imperfect study designs or to a substantial inefficacy of pacing therapies. AIM: To intraindividually compare AT burden between an atrial overdrive and two heart rate modulation approaches: a conventional accelerometric-sensor-based DDDR mode and a contractility-driven rate responsive closed loop (CLS) algorithm. METHODS AND RESULTS: Four hundred fifty-one patients with Brady-Tachy syndrome (BTS), severe bradycardia, and a documented episode of atrial fibrillation were enrolled. One month after implant, each pacing therapy was activated for 3 months in random order. A simple log transformation was used to handle large and skew AT burden distributions. Estimates were adjusted for false-positive AT episodes and reported as geometric means (95% confidence interval). A significantly higher AT burden was observed during overdrive, 0.14% (0.09%, 0.23%) (adjusted, 0.12%[0.07%, 0.20%]). Both DDDR and CLS performed better: respectively, 0.11% (0.07%, 0.17%) (adjusted, 0.08%[0.05%, 0.14%]), 0.06% (0.03%, 0.09%) (adjusted, 0.04%[0.03%, 0.07%]). All the comparisons were statistically significant. During overdrive significantly more patients had AT episodes of duration between 1 minute and 1 hour. No significant differences were observed for longer episodes. CONCLUSIONS: Atrial overdrive showed the worst performance in terms of AT burden reduction and should not be preferred to heart rate modulation approaches that still have to be considered as a first-choice pacing mode in BTS.


Asunto(s)
Bradicardia/epidemiología , Bradicardia/prevención & control , Estimulación Cardíaca Artificial/métodos , Estimulación Cardíaca Artificial/estadística & datos numéricos , Medición de Riesgo/métodos , Taquicardia Atrial Ectópica/epidemiología , Taquicardia Atrial Ectópica/prevención & control , Anciano , Bradicardia/diagnóstico , Comorbilidad , Femenino , Humanos , Italia/epidemiología , Masculino , Factores de Riesgo , Taquicardia Atrial Ectópica/diagnóstico , Resultado del Tratamiento
2.
Europace ; 8(3): 216-20, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16627443

RESUMEN

AIMS: Autocapture is an algorithm for automatic adaptation of ventricular output to capture threshold. The aim of this prospective study was to estimate the effects of ventricular Autocapture algorithm on DDD-DDDR pacemaker longevity. METHODS AND RESULTS: Eighty-three patients implanted with a DDD-DDDR pacemaker (Affinity or Entity; St Jude Medical, USA) were enrolled and the Autocapture function was activated pre-discharge. Ventricular pulse duration was randomly programmed at 0.3 or 0.4 ms, with a cross-over at 8-12 weeks and again at 13-14 months. Diagnostic data were retrieved from device memory and by calculating battery current drain from long-term threshold recordings; device longevity was estimated at the following settings: Autocapture with a pulse duration of 0.3 and 0.4 ms, respectively, standard output (3.5 V, 0.4 ms) and conventional low output programming (2.5 V, 0.4 ms). According to a series of assumptions, Autocapture was associated with a 55-60% increase in estimated device longevity compared with standard output programming and a 6-7% increase in longevity compared with low output programming. No significant differences were found between Autocapture programmed with a pulse duration of 0.3 or 0.4 ms. In projections to a 10-year follow-up, use of the Autocapture function resulted in a 42% reduction in pacing-related estimated costs compared with standard output programming at 3.5 V, 0.4 ms. CONCLUSION: Pacing with constant adaptation of ventricular output in dual-chamber devices has the potential to increase generator longevity and to reduce sizeably pacing-related costs compared with standard programming.


Asunto(s)
Estimulación Cardíaca Artificial , Suministros de Energía Eléctrica , Marcapaso Artificial , Función Ventricular , Adulto , Anciano , Anciano de 80 o más Años , Estudios Cruzados , Falla de Equipo , Femenino , Bloqueo Cardíaco/fisiopatología , Bloqueo Cardíaco/terapia , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA